background image

Copyright © 2020 NEXCOM International Co., Ltd. All Rights Reserved.

25

NISE 108 User Manual 

Chapter 2: Jumpers and Connectors

74

75

1

2

Pin

definition

Pin

definition

1

CONFIG_3

2

3.3V_1

3

GND1

4

3.3V_2

5

GND2

6

POWER_OFF#

7

USB_D+

8

W_DISABLE1#

9

USB_D-

10

GPIO_9/DAS/DSS#

11

REFCLK-

12

17

18

19

20

GPIO_5

21

CONFIG_0

22

GPIO_6

23

GPIO_11

24

GPIO_7

25

DPR

26

GPIO_10

27

GND3

28

GPIO_8

29

PERn1/USB3.0-Rx-/SSIC-RxN

30

UIM-RESET

31

PERp1/USB3.0-Rx+/SSIC-RxP

32

UIM-CLK

33

GND4

34

UIM-DATA

35

PETn1/USB3.0-Tx-/SSIC-TxN

36

UIM-PWR

37

PETn1/USB3.0-Tx+/SSIC-TxP

38

DEVSLP

39

GND5

40

GPIO_0

Pin

definition

Pin

definition

41

PERn0/SATA-B+

42

GPIO_1

43

PERp0/SATA-B-

44

GPIO_2

45

GND6

46

GPIO_3

47

PERn0/SATA-A-

48

GPIO_4

49

PERp0/SATA-A+

50

PERST#

51

GND7

52

CLKREQ#

53

REFCLKn

54

PEWAKE#

55

REFCLKp

56

NC_1

57

GND8

58

NC_2

59

ANTC TL0

60

COEX3

61

ANTC TL1

62

COEX2

63

ANTC TL2

64

COEX1

65

ANTC TL3

66

SIM_DETECT

67

RESET#

68

SUSCLK (32KhZ)

69

CONFIG_1

70

3.3V_3

71

GND9

72

3.3V_4

73

GND10

74

3.3V_5

75

CONFIG_2

M.2 Connector (B-Key)

Connector location: NGFF1

Summary of Contents for 10J00010800X0

Page 1: ...NEXCOM International Co Ltd NEXCOM International Co Ltd Published March 2020 www nexcom com IoT Automation Solutions Business Group Fan less Computer NISE 108 User Manual ...

Page 2: ...apter 1 Product Introduction NISE 108 Overview 1 Key Features 1 Hardware Specifications 2 Knowing Your NISE 108 4 Front Panel 4 Rear Panel 4 Mechanical Dimensions 5 Chapter 2 Jumpers and Connectors Before You Begin 6 Precautions 6 Jumper Settings 7 Locations of the Jumpers and Connectors for NISB 108 8 NISB 108 8 Jumpers 10 LVDS Panel Power Selection 10 Backlight Volume Selection 10 Clear CMOS 11 ...

Page 3: ...onnector 24 M 2 Connector B Key 25 Chapter 3 System Setup Removing the Chassis Bottom Cover 26 Installing a SO DIMM Memory Module 27 Installing a Wireless LAN Module Half size 29 Installing an M 2 Storage Module 2242 31 Installing a SATA Storage Drive 33 Wall Mounting Instructions 35 Chapter 4 BIOS Setup About BIOS Setup 36 When to Configure the BIOS 36 Default Configuration 37 Entering Setup 37 L...

Page 4: ...EXCOM International Co Ltd All other product names mentioned herein are registered trademarks of their respective owners Regulatory Compliance Statements This section provides the FCC compliance statement for Class A devices and describes how to keep the system CE compliant Declaration of Conformity FCC This equipment has been tested and verified to comply with the limits for a Class A digital dev...

Page 5: ...d Polybrominated diphenyl Ethers PBDE 0 1 or 1 000ppm In order to meet the RoHS compliant directives NEXCOM has established an engineering and manufacturing task force to implement the introduction of green products The task force will ensure that we follow the standard NEXCOM development procedure and that all the new RoHS components and new manufacturing processes maintain the highest industry q...

Page 6: ...onsible for the safe packaging of defective products making sure it is durable enough to be resistant against further damage and deterioration during transportation In case of damages occurred during transportation the repair is treated as Out of Warranty Any products returned by NEXCOM to other locations besides the customers site will bear an extra charge and will be billed to the customer Repai...

Page 7: ...nd power supply are inconsistent with these instructions or the instructions for accessory modules contact the supplier to find out how you can ensure that your computer meets safety and regulatory requirements Cautions Electrostatic discharge ESD can damage system components Do the described procedures only at an ESD workstation If no such station is available you can provide some ESD protection ...

Page 8: ...note the following precautions Read all instructions carefully Do not place the unit on an unstable surface cart or stand Follow all warnings and cautions in this manual When replacing parts ensure that your service technician uses parts specified by the manufacturer Avoid using the system near water in direct sunlight or near a heating device The load of the system unit does not solely rely for s...

Page 9: ... and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel 14 The equipment is intended to b...

Page 10: ...ion of the installed software operating system version application software etc A complete description of the problem The exact wordings of the error messages Warning 1 Handling the unit carry the unit with both hands and handle it with care 2 Maintenance to keep the unit clean use only approved cleaning products or clean with a dry cloth Conventions Used in this Manual Warning Information about c...

Page 11: ...hung Office 16F No 250 Sec 2 Chongde Rd Beitun Dist Taichung City 406 R O C Tel 886 4 2249 1179 Fax 886 4 2249 1172 Email sales nexcom com tw www nexcom com tw NexCOBOT Taiwan Co Ltd 13F No 916 Chung Cheng Rd ZhongHe District New Taipei City 23586 Taiwan R O C Tel 886 2 8226 7796 Fax 886 2 8226 7792 Email sales nexcom com tw www nexcom com tw GreenBase Technology Corp 13F No 922 Chung Cheng Rd Zho...

Page 12: ...mingzun Plaza Bldg 1 No 609 Yunlin East Rd Shanghai 200062 China Tel 86 21 5278 5868 Fax 86 21 3251 6358 Email sales nexcom cn www nexcom cn NEXCOM Surveillance Technology Corp Floor 5 Building C ZhenHan Industrial Zone GanKeng Community Buji Street LongGang District ShenZhen 518112 China Tel 86 755 8364 7768 Fax 86 755 8364 7738 Email steveyang nexcom com tw www nexcom cn NEXCOM United System Ser...

Page 13: ...NIGP F2x4 NIGP Nylok 1 4 50311F0326X00 Flat Head Screw Long Fei F3x5 Nylok NI Heat Treatment F3x5 Nylok NI Heat Treatment 4 5 50311F0330X00 Round Head Screw Long Fei P2x3 ISO Nylon P2x3 NI Nylok 2 6 50311F0530X00 I Head Screw Long Fei I3x6 ISO I3x6 ISO w Spring Washer NI 1 7 5060900226X00 Mini PCIe Bracket Chyuan JYH 29x30x2 1mm SPCC t 1 0mm NI 1 8 5061600107X00 Transistor Washer for VTC 1020 Kang...

Page 14: ...E 108 User Manual Preface Ordering Information The following information below provides ordering information for NISE 108 NISE 108 P N 10J00010800X0 Intel Celeron processor J3455 quad core 1 50GHz fanless system 24V 60W AC DC power adapter w o power cord P N 7400060032X00 ...

Page 15: ...eatures Onboard Intel Celeron processor J3455 quad core 1 50GHz Dual independent display from DP1 DP2 2 x Intel I210 IT GbE LAN ports support WoL teaming and PXE 2 x USB 2 0 2 x USB 3 0 3 x COM ports COM3 with RS232 422 485 jumper free setting Support both 2 5 HDD and M 2 Support 5 55 degree C operating temperature Support 24 VDC input NISE 108 Overview ...

Page 16: ...ing function via jumper setting default setting is ring 1 x 3 pin DC input support 24 VDC input 1 x Antenna hole for optional Wi Fi 3 5G antenna 1 x 3 pin remote power on off switch I O Interface Rear 1 x Antenna hole for optional Wi Fi 3 5G antenna Storage Device 1 x M 2 SATA 2 0 1 x 2 5 HDD SATA 2 0 Expansion Slot 1 x mini PCIe socket for optional Wi Fi 3 5G 4G module For 3 5G 4G function mini P...

Page 17: ...ion protection w HDD condition Random 0 5Grms 5 500 Hz IEC60068 2 64 Sinusoidal 0 5Grms 5 500 Hz IEC60068 2 6 Vibration protection w SSD condition Random 2Grms 5 500 Hz IEC60068 2 64 Sinusoidal 2Grms 5 500 Hz IEC60068 2 6 Certifications CE FCC Class A OS Support List Windows 10 IoT Enterprise 64 bit Linux kernel version 4 1 ...

Page 18: ... 2 0 1 1 devices DisplayPort1 DisplayPort2 Used to connect a DisplayPort interface monitor LED Indicators Two LEDs used to indicate the power status and storage activity of the system The third LED is user programmable Power Switch Press to power on or power off the system COM1 to COM3 Three DB9 ports used to connect RS232 compatible devices COM3 supports RS232 422 485 connection Remote On Off Swi...

Page 19: ...Copyright 2020 NEXCOM International Co Ltd All Rights Reserved 5 NISE 108 User Manual Chapter 1 Product Introduction Mechanical Dimensions 206 00 184 85 131 00 115 00 60 00 54 00 ...

Page 20: ...rself before touching any internal components by touching a metal object Static electricity can damage many of the electronic components Humid environments tend to have less static electricity than dry environments A grounding strap is warranted whenever danger of static electricity exists Precautions Computer components and electronic circuit boards can be damaged by discharges of static electric...

Page 21: ... jumpers ensure that the jumper caps are placed on the correct pins When the jumper cap is placed on both pins the jumper is short If you remove the jumper cap or place the jumper cap on just one pin the jumper is open Refer to the illustrations below for examples of what the 2 pin and 3 pin jumpers look like when they are short on and open off Two Pin Jumpers Open Left and Short Right Three Pin J...

Page 22: ... figures are the top and bottom view of the NISB 108 main board which is the main board used in NISE 108 It shows the locations of the jumpers and connectors 9 18 4 1 5 14 2 1 3 1 2 3 1 2 R349 3 1 A1 A3 A2 C1 C3 C2 1 5 4 8 19 20 2 1 20 19 1 2 A2 A1 A10 B1 A9 B2 B9 B10 BJ BA U35 AL AA L A 63 60 50 40 30 20 10 1 J1 DP2 DP1 LED1 USB2 USB1 LAN1B LAN1A DV24V IN1 PWR_BT1 CLR_CMOS1 CLR_CMOS2 Top View ...

Page 23: ...51 52 17 18 15 16 1 2 3 3 5 5 10 10 10 19 20 1 1 2 2 2 6 6 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 3 5 10 1 P15 P1 S7 S1 19 20 2 1 19 20 2 D I M M 1 74 72 203 73 71 COM3 SATA1 MPCIE1 NGFF1 COM2 COM1 GPIO1 DB1 FRONT1 TOUCH1 W_USB1 WLED1 REM_BT1 INV1 LVDS1 JBLT_PWM1 JPWR_MODE1 JCOM2_RI1 JPNL_PWR1 LVDS2 MPCIe1 SATA1 M 2 CONNECTOR Bottom View ...

Page 24: ...rs and Connectors Jumpers LVDS Panel Power Selection Connector type 1x3 3 pin header 2 54mm pitch Connector location JPNL_PWR1 Backlight Volume Selection Connector type 1x3 3 pin header 2 54mm pitch Connector location JBLT_PWM1 1 3 1 3 Pin Settings 1 2 On 3V3 2 3 On 5V Pin Settings 1 2 On 3V3 2 3 On 5V ...

Page 25: ...umpers and Connectors Clear CMOS Connector type 1x3 3 pin header 2 54mm pitch Connector location CLR_CMOS1 and CLR_CMOS2 ATX AT Mode Selection Connector type 1x3 3 pin header 2 54mm pitch Connector location JPWR_MODE1 1 3 1 3 Pin Settings 1 2 On Normal 2 3 On Clear Pin Settings 1 2 On ATX 2 3 On AT ...

Page 26: ...l Co Ltd All Rights Reserved 12 NISE 108 User Manual Chapter 2 Jumpers and Connectors COM2 Port Power Setting Connector type 2x3 6 pin header 2 0mm pitch Connector location JCOM2_RI1 1 5 2 6 Pin Settings 1 2 On 12V 3 4 On Ring 5 6 On 5V ...

Page 27: ...Green Connector Pin Definitions External I O Interfaces LED Indicators Connector location LED1 1 2 3 PG DisplayPorts Connector type DisplayPort Connector location DP1 and DP2 Pin Definition Pin Definition 1 LANE0_P 2 GND 3 LANE0_N 4 LANE1_P 5 GND 6 LANE1_N 7 LANE2_P 8 GND 9 LANE2_N 10 LANE3_P 11 GND 12 LANE3_N 13 CONFIG1 14 CONFIG2 15 AUX_P 16 GND 17 AUX_N 18 HPD 19 DP_RETURN 20 DP_PWR 2 1 19 20 ...

Page 28: ..._C 7 GND 8 USB3_TX0_N_C 9 USB3_TX0_P_C 10 5V 11 USB_1N_C 12 USB_1P_C 13 GND 14 USB3_RX1_N_C 15 USB3_RX1_P_C 16 GND 17 USB3_TX1_N_C 18 USB3_TX1_P_C Pin Definition Pin Definition 1 5V 2 USB_2N_C 3 USB_2P_C 4 GND 5 5V 6 USB_3N_C 7 USB_3P_C 8 GND 9 1 10 13 14 18 4 5 USB 3 0 Ports Connector type Dual USB 3 0 port Connector location USB1 USB 2 0 Ports Connector type Dual USB 2 0 port Connector location ...

Page 29: ...4 MDI_MINUS1 5 MDI_PLUS2 6 MDI_MINUS2 7 MDI_PLUS3 8 MDI_MINUS3 Pin Definition Pin Definition 1 MDI_PLUS0 2 MDI_MINUS0 3 MDI_PLUS1 4 MDI_MINUS1 5 MDI_PLUS2 6 MDI_MINUS2 7 MDI_PLUS3 8 MDI_MINUS3 ACT LINK 8 1 ACT LINK 8 1 Act Status Flashing Yellow Data activity Off No activity Link Status Steady Green 1G network link Steady Orange 100Mbps network link Off 10Mbps or no link Act Status Flashing Yellow...

Page 30: ...l Co Ltd All Rights Reserved 16 NISE 108 User Manual Chapter 2 Jumpers and Connectors 24V DC Power Input Connector type Phoenix Contact 1x3 3 pin terminal block Connector location DC24V_IN1 Pin Definition 1 24V 2 GND 3 CHASSIS GND G 1 3 ...

Page 31: ...e 1x10 10 pin header 1 0mm pitch Connector location DB1 LED Connector Connector type 1x5 5 pin header 2 0mm pitch Connector location WLED1 Pin Definition Pin Definition 1 GND 2 LPC_PLTRST 3 LPC_CLK 4 LPC_LFRAME 5 LPC_LAD3 6 LPC_LAD2 7 LPC_LAD1 8 LPC_LAD0 9 LPC_SERIRQ 10 3 3V Pin Definition Pin Definition 1 HDD_LED 2 HDD_LED 3 GND 4 STBY_LED 5 POWER_LED 6 1 5 1 0 1 1 10 ...

Page 32: ...D 15 GND 16 V_INV 17 LVDSA_LDC2P 18 V_INV 19 LVDSA_LDC2N 20 GND Pin Definition Pin Definition 1 CH7511_GPIO2 2 CH7511_GPIO3 3 VCC_LCD 4 LVDSB_LDC4P 5 LVDSB_LDC7P 6 LVDSB_LDC4N 7 LVDSB_LDC7N 8 VCC_LCD 9 GND 10 LVDSB_LDC5P 11 LVDSB_LL2CP 12 LVDSB_LDC5N 13 LVDSB_LL2CN 14 GND 15 GND 16 V_INV 17 LVDSB_LDC6P 18 V_INV 19 LVDSB_LDC6P 20 GND LVDS Connector Connector type 2x10 20 pin header 1 25mm pitch Con...

Page 33: ...mm pitch Connector location INV1 Pin Definition Pin Definition 1 5V 2 12V 3 12V 4 BKCTRL 5 GND 6 GND 7 BKLEN 7 1 Front Panel Connector Connector type 2x7 14 pin header 2 0mm pitch Connector location FRONT1 1 13 2 14 Pin Definition Pin Definition 1 PWR_LED 2 PWR_LED 3 HDD_LED 4 HDD_LED 5 MAIN_SMBCLK 6 3V3 7 MAIN_SMBDATA 8 GND 9 SLP_S3 10 PS_ON 11 PWR_BTN 12 GND 13 RST _BTN 14 GND ...

Page 34: ...Internal USB 2 0 Connector Connector type 1x6 6 pin header 2 5mm pitch Connector location W_USB1 Pin Definition Pin Definition 1 5V 2 USB_4N_C 3 USB_4P_C 4 5 6 GND 1 6 Touch Screen Connector Connector type 1x5 5 pin header 2 5mm pitch Connector location TOUCH1 Pin Definition Pin Definition 1 UR 2 LR 3 Sense 4 UL 5 LL 1 5 ...

Page 35: ...2 0mm pitch Connector location REM_BT1 Pin Definition 1 REMOTE_S3 2 GND 3 REMOTE_ PWRBT 3 1 GPIO Connector Connector type 2x10 20 pin header 2 0mm pitch Connector location GPIO1 Pin Definition Pin Definition 1 5V 2 5V 3 GPO_0 4 GPI_0 5 GPO_1 6 GPI_1 7 GPO_2 8 GPI_2 9 GPO_3 10 GPI_3 11 GPO_4 12 GPI_4 13 GPO_5 14 GPI_5 15 GPO_6 16 GPI_6 17 GPO_7 18 GPI_7 19 GND 20 GND 1 19 2 20 ...

Page 36: ... type 1x10 10 pin header Connector location COM3 COM1 and COM2 Connectors RS232 Connector type 1x10 10 pin header Connector location COM1 and COM2 1 0 1 1 10 1 0 1 1 10 Pin Definition Pin Definition 1 DCD TX 2 RXD TX 3 TXD RX 4 DTR RX 5 GND 6 DSR 7 RTS 8 CTS 9 RI 10 GND Pin Definition Pin Definition 1 DCD 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI 10 GND ...

Page 37: ... GND S5 SATA1_RXN S6 SATA1_RXP S7 GND P1 VCC3 P2 VCC3 P3 VCC3 P4 GND P5 GND P6 GND P7 VCC5 P8 VCC5 P9 VCC5 P10 GND P11 VCC5 P12 GND P13 VCC12 P14 VCC12 P15 VCC12 SATA Connector 7 pin and 15 pin Connector type Standard Serial ATA 7P and 15P Connector location SATA1 S1 P15 Battery Connector Connector type 1x2 2 pin header 1 25mm pitch Connector location J1 Pin Definition 1 GND 2 3V 1 2 ...

Page 38: ...3 REFCLK 14 UIM_RESET 15 GND5 16 UIM_VPP 17 REV10 UIM_C8 18 GND11 19 REV9 UIM_C4 20 W_DISABLE 21 GND4 22 PERST 23 PERn0 24 3 3VSB_1 25 PERp0 26 GND10 Mini PCIe Connector Connector location MPCIE1 Pin Definition Pin Definition 27 GND3 28 1 5V_2 29 GND2 30 SMB_CLK 31 PETn0 32 SMB_DAT 33 PETp0 34 GND9 35 GND0 36 USB_D 37 GND13 38 USB_D 39 3 3VSB_4 40 GND8 41 3 3VSB_5 42 LED_WWAN 43 GND14 44 LED_WLAN ...

Page 39: ...SET 31 PERp1 USB3 0 Rx SSIC RxP 32 UIM CLK 33 GND4 34 UIM DATA 35 PETn1 USB3 0 Tx SSIC TxN 36 UIM PWR 37 PETn1 USB3 0 Tx SSIC TxP 38 DEVSLP 39 GND5 40 GPIO_0 Pin Definition Pin Definition 41 PERn0 SATA B 42 GPIO_1 43 PERp0 SATA B 44 GPIO_2 45 GND6 46 GPIO_3 47 PERn0 SATA A 48 GPIO_4 49 PERp0 SATA A 50 PERST 51 GND7 52 CLKREQ 53 REFCLKn 54 PEWAKE 55 REFCLKp 56 NC_1 57 GND8 58 NC_2 59 ANTC TL0 60 CO...

Page 40: ...CAUTION CAUTION CAUTION 1 Locate the six mounting screws from the bottom cover 2 Remove the six mounting screws from the bottom cover 3 With the screws removed lift up the cover and remove it from the chassis Prior to removing the chassis bottom cover make sure the unit s power is off and disconnected from the power sources to prevent electric shock or system damage ...

Page 41: ...ottom cover before installing a SO DIMM Installing a SO DIMM Memory Module 2 Insert the module into the socket at an approximately 30 degree angle The ejector tabs at the ends of the socket will automatically snap into the locked position to hold the module in place 1 Locate the SO DIMM socket SO DIMM Socket Memory Module ...

Page 42: ...Copyright 2020 NEXCOM International Co Ltd All Rights Reserved 28 NISE 108 User Manual Chapter 3 System Setup 3 Push the module down until the clips on both sides of the socket lock into position ...

Page 43: ...l Co Ltd All Rights Reserved 29 NISE 108 User Manual Chapter 3 System Setup Installing a Wireless LAN Module Half size 1 Locate the mini PCIe slot on the board 2 Install the mini PCIe bracket to the mini PCIe module Screw Mini PCIe Slot ...

Page 44: ...NISE 108 User Manual Chapter 3 System Setup 3 Insert the WLAN module into the mini PCIe slot at 45 degree angle until the gold plated connector on the edge of the module completely disappears into the slot 4 Push the module down and secure it with a screw WLAN Module ...

Page 45: ...User Manual Chapter 3 System Setup Installing an M 2 Storage Module 2242 1 Locate the M 2 B key slot on the board M 2 B Key Slot 2 Make sure the gold plated six pin connector on the edge of the module is on the left while the five pin connector is on the right Six Pin Five Pin ...

Page 46: ... NISE 108 User Manual Chapter 3 System Setup 3 Insert the M 2 module into the M 2 slot at 45 degree angle until the gold plated connector on the edge of the module completely disappears into the slot M 2 Module Screw 4 Push the module down and secure it with a screw ...

Page 47: ...tup Remove the bottom cover before installing a SATA drive Installing a SATA Storage Drive 1 Locate the internal storage bracket and remove all the three screws on the storage bracket 2 Place the 2 5 storage drive into the internal storage bracket then use the screws to secure the 2 5 storage drive in place ...

Page 48: ...4 NISE 108 User Manual Chapter 3 System Setup 3 Place the internal storage bracket back to its original position Before securing the bracket with screws make sure the washers are aligned on top of the mounting holes 4 Secure the internal storage bracket with screws ...

Page 49: ...he bottom surface 2 Secure the brackets to the system by inserting two retention screws into each bracket Wall Mounting Instructions Wall Mount Bracket Specification of the wall mount screw Round Head Screw Long Fei P6 32Tx 1 4 SW7 0 8 w Spring Flat Washer 3 Drill holes in the intended installation surface 4 Align the mounting holes on the sides of the mounting brackets with the predrilled holes o...

Page 50: ...s configured with the values found in CMOS With easy to use pull down menus you can configure such items as Hard drives diskette drives and peripherals Video display type and display options Password protection from unauthorized use Power management features The settings made in the setup program affect how the computer performs It is important therefore first to try to understand all the setup op...

Page 51: ...l be reported in one of two different ways If the error occurs before the display device is initialized a series of beeps will be transmitted If the error occurs after the display device is initialized the screen will display the error message Powering on the computer and immediately pressing Del allows you to enter Setup Press the key to enter Setup Legends Key Function Moves the highlight left o...

Page 52: ...up screen it indicates that there are more available fields not shown on the screen Use the up and down arrow keys to scroll through all the available fields Submenu When appears on the left of a particular field it indicates that a submenu which contains additional options are available for that field To display the submenu move the highlight to that field and press ...

Page 53: ...it Set the Date Use Tab to switch between Date elements Default Ranges Year 2005 2099 Months 1 12 Days dependent on month BIOS Information BIOS Vendor Core Version Compliancy Project Version Build Date and Time Access Level Platform firmware Information BXT SOC TXE FW GOP Memory Information Total Memory Memory Speed System Date System Time American Megatrends 5 12 UEFI 2 5 PI 1 4 N108A008 x64 08 3...

Page 54: ... Settings IT8786E Super IO Configuration Hardware Monitor CPU Configuration Network Stack Configuration NVMe Configuration Trusted Computing USB Configuration ACPI Settings This section is used to configure ACPI settings Enable Hibernation Enables or disables system ability to hibernate OS S4 Sleep State This option may not be effective with some OS ACPI Sleep State Select the highest ACPI sleep s...

Page 55: ... Optimized Defaults F4 Save Exit ESC Exit Set Parameters of Serial Port 1 COMA IT8786E Super IO Configuration Super IO Chip Serial Port 1 Configuration Serial Port 2 Configuration Serial Port 3 Configuration IT8786E Serial Port 1 Configuration This section is used to configure serial port 1 Serial Port Enables or disables the serial port Advanced Version 2 18 1263 Copyright C 2019 American Megatre...

Page 56: ...American Megatrends Inc Aptio Setup Utility Copyright C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enable or Disable Serial Port COM Serial Port 2 Configuration Serial Port Device Settings Enabled IO 2F8h IRQ 5 Advanced Version 2 18 1263 Copyright C 2019 American Megatrends Inc Aptio ...

Page 57: ... System temperature VCore VCC3 VCC12 VCC5 29 c 29 c 0 828 V 3 366 V 12 096 V 4 980 V Advanced Version 2 18 1263 Copyright C 2019 American Megatrends Inc Aptio Setup Utility Copyright C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Socket specific CPU Information CPU Configuration Socket ...

Page 58: ...eron R CPU J3455 1 50GHz CPU Signature Microcode Patch Max CPU Speed Min CPU Speed Processor Cores Intel HT Technology Intel VT x Technology L1 Data Cache L1 Code Cache L2 Cache L3 Cache 506CA 1A 1500 MHz 800 MHz 4 Not Supported Supported 24 kB x 4 32 kB x 4 1024 kB x 2 Not Present Advanced Version 2 18 1263 Copyright C 2019 American Megatrends Inc Aptio Setup Utility Copyright C 2019 American Meg...

Page 59: ...n Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enable Disable UEFI Network Stack Network Stack Disabled Advanced Version 2 18 1263 Copyright C 2019 American Megatrends Inc Aptio Setup Utility Copyright C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized...

Page 60: ...s Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available Configuration Security Device Support NO Security Device Found Disable Security Device Support Enables or disables BIOS...

Page 61: ...ous Values F3 Optimized Defaults F4 Save Exit ESC Exit This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by the XHCI driver USB Configuration USB Module Version USB Controllers 1 XHCI USB Devices 1 Keyboard 2 Mice XHCI Hand off USB Mass Storage Driver Support USB hardware delays and time outs USB transfer time out Device reset time out Device p...

Page 62: ...t C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit South Bridge South Cluster Configuration South Bridge SMBus Support Enables or disables SMBus support Save Exit Advanced Chipset Boot Security Main Version 2 18 1263 Copyright C 2019 American Megatrends Inc Aptio Setup Utility Copyright C...

Page 63: ...evious Values F3 Optimized Defaults F4 Save Exit ESC Exit HD Audio Configuration Settings HD Audio Configuration SATA Drives USB Configuration Miscellaneous Configuration Save Exit Advanced Chipset Boot Security Main Version 2 18 1263 Copyright C 2019 American Megatrends Inc Aptio Setup Utility Copyright C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General He...

Page 64: ...nternal SATA ports up to 3Gb s supported per port SATA Drives Chipset SATA Controller Configuration Chipset SATA SATA Port 0 Port 0 SATA Port 1 Port 1 Enable 2 5 SATA SSD 64 0GB Enabled M 2 S42 3ME4 32 0GB Enabled USB Configuration xHCI Mode Enables or disables XHCI mode Once disabled XHCI controller function will be disabled and all the USB devices will not be detectable and usable during boot up...

Page 65: ...1 Power State in S5 USB2 3 Power State in S5 USB4 Power State in S5 Enable S0 State ON ON ON Security Save Exit Advanced Chipset Security Boot Main Version 2 18 1263 Copyright C 2019 American Megatrends Inc Aptio Setup Utility Copyright C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Set...

Page 66: ... American Megatrends Inc Aptio Setup Utility Copyright C 2019 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Select the keyboard NumLock state Boot Configuration Bootup NumLock State Quiet Boot Boot Option Priorities Boot Option 1 Boot Option 2 Boot Option 3 Fast Boot On Disabled Windows Boot ...

Page 67: ... the system after saving the changes Save Options Save Changes and Reset Discard Changes and Reset Default Options Restore Defaults Save Exit Save Changes and Reset To save the changes and reset select this field then press Enter A dialog box will appear Confirm by selecting Yes Discard Changes and Reset To exit the Setup utility and reboot the system without saving the changes select this field t...

Page 68: ...ory Innodisk 8GB DDR3L SO DIMM 4 HDD Innodisk 2 5 SATA SSD M3E4 1TB 5 M 2 Innodisk 128GB 3ME4 M 2 6 Wi Fi SPARKLAN WPEQ 261ACNI 7 Power Supply DC Power Supply 62006P 100 25 Test Procedure 1 Power up the DUT boot into Windows 10 x64 2 Enter standby mode SSD power down 3 Measure the power consumption and record it 4 Run burn in test program and apply 100 full loading 5 Measure the power consumption ...

Page 69: ...ins in NISE 108 The pin definition is shown in the following table Pin GPI O Mode PowerOn Default Address Pin GPI O Mode Address 1 VCC 2 GND 3 GPO0 Low A04h Bit6 4 GPI0 A06h Bit0 5 GPO1 Low A04h Bit7 6 GPI1 A06h Bit1 7 GPO2 Low A05h Bit0 8 GPI2 A06h Bit2 9 GPO3 Low A05h Bit1 10 GPI3 A06h Bit3 11 GPO4 Low A07h Bit4 12 GPI4 A06h Bit4 13 GPO5 Low A07h Bit5 14 GPI5 A06h Bit5 15 GPO6 Low A07h Bit6 16 G...

Page 70: ... Guide Appendix C Led Programming Guide LEDs are provided for custom system design This appendix provides definitions and its default setting for the LEDs in NISE 108 The LED definition is shown in the following table Pin PowerOn Default Address LED1 C3 High A03h Bit0 The bit is Set Clear indicated output High Low ...

Reviews: