ZLS-101
Water detector
TECHNICAL DATA
Power source, battery
3V – 1 x CR-123
Frequency
Z-Wave (868.42 MHz)
Range
up to 30 m
IP rating
Indoor use
Operating temperature
-10°C to +50 °C >95% RH
Cable length
120 cm
Dimensions (W x H x D)
26 x 72 x 21 mm Sensor: 29 x 27 x 14 mm
ENGLISH
NEXA AB, DATAVÄGEN 37B, SE-436 32 ASKIM, SWEDEN
[email protected] | www.nexa.se
SAFETY AND INFORMATION
Range indoors:
up to 30 m (optimal conditions). The range is
very dependent on the local conditions, for example, if there are
metals in the vicinity. For example, the thin metal coating in energy
glass with low emissivity has a negative influence on the range
of the radio signals. There may be restrictions on the use of the
unit outside the EU. If appropriate, you should check that the unit
complies with local regulations.
Life-support equipment: Never use Nexa products for life-support
equipment or other devices where faults or interference could have
life-threatening consequences.
Interference: All wireless units can suffer from interference that can
affect the performance and range. For this reason, the minimum
distance between two receivers should be at least 50 cm
Repair:
Do not attempt to repair the product. It does not contain
any repairable parts.
Waterproofing: The product is not waterproof. Make sure it is dry
at all times. Damp causes the electronics inside to corrode and this
could lead to short-circuiting, faults and a risk for electric shocks.
Cleaning: Clean the product with a dry cloth. Do not use chemicals,
solvents or strong cleaning agents.
Environment: Do not expose the product to intense heat or cold,
because it could damage or shorten the service life of the electric
circuits.
The ZLS-101 is a Z-Wave Plus water detector that signals when
the sensor detects water for a Nexa Bridge or other control device
with Z-Wave certification. The sensor and detector are linked using
a 120 cm cable that must not be cut or spliced. The water detector
has a sabotage alarm.
SAFETY
Read through the entire instruction first. Engage a professional if so
required. Nexa cannot be held liable if the product is used for any
purpose other than the one for which it is designed, or if there is
failure to comply with the instruction.
INSTALLATION
The detector and sensor are installed using double-sided tape.
Thoroughly clean the surface where the sensor is to be positioned
before installing it. The detector should be placed in a readily
accessible location so that the battery can be replaced in future.
CONNECT TO A Z-WAVE NETWORK
Push down the backpiece of the detector and pull off the battery’s
protective tab to activate the detector.
Inclusion:
1. Put the Z-Wave controller in exclusion mode (see the manual for
the controller)
2. Press the sabotage switch 3 times within 1.5 seconds. The LED
indicator will flash rapidly.
Exclusion:
1. Put the Z-Wave controller in exclusion mode (see the manual for
the controller)
2. Press the sabotage switch 3 times within 1.5 seconds.
3. The LED indicator flashes 6 times when exclusion is complete.
FACTORY RESET
1. Hold down the sabotage switch for 10 seconds.
2. Remove the battery without releasing the sabotage switch.
EXTENDED Z-WAVE CONFIGURATION
Can be found under the product at www.nexa.se
Sabotage
switch
Battery
LED
indication
DETECTOR
SENSOR