6
3.2 ADJUST
ING THE FEET
This cooker stands on 4 levelling legs. As the legs are initially on a lower position,
you must adjust them to make sure the cooker is balanced before using it. If you
need to balance the cooker, the legs can be adjusted by turning them clockwise.
You can raise the cooker by a maximum of
15mm via the leveling leg
s
. If
you
have had to adjust the cooker with the levelling legs make sure to move the
cooker by lifting it rather than dragging it. The levelling leg can be adjusted by
hand or a suitable size coin.
3.3 ELECTRIC CONNECTION AND SAFETY
During the electric
al
connection,
make
sure
you
follow the instructions below
:
Rated power on
nameplate:
Diameter of supply
cable:
Rated power on
nameplate:
Diameter of supply
cable:
5000W -8700W
at 220V:
3 x 2.5 mm
2
> 8700W at 220 V
3 x 4.0 mm
2
5000W -9100W
at 230V:
3 x 2.5 mm
2
> 9100W at 230 V
3 x 4.0 mm
2
5000W -9500W
at 240V:
3 x 2.5 mm
2
> 8700W at 240 V
3 x 4.0 mm
2
Before proceeding with the electrical connection, verify that the current carrying
capacity of the system and the socket is adequate for the maximum power rating
of the oven.
Electrical installation of the residence and the electrical current plug in use must
be earthed and conform to safety regulations.
A circuit breaker with a contact opening of at least 3 mm must be installed inside
the supply circuit.
Do not use adaptors, multiple sockets and/or extension leads.
Fused switch must be accessible once the oven has been installed.
IMPORTANT: The following diameters of supply cable
are the minimum
required thickness
in case of one phase connection: