Newton Waterproofing Victron MultiPlus 12/3000/120 Installation Manual Download Page 7

Call us for more information on +44 (0)1732 360095

7

Example 3

 - 2 x Automatic Pumps - 1 x Pump Control Panels - 1 x Inverter/Charger Control Panels - 1 x Battery 

Monitor Module

POSITIONING

NOTE: ALL POWER INVETERS NEED TO BE INSTALLED INTERNALLY IN A DRY AND WELL VENTILATED SPACE
•  The product is suitable for wall mounting
•  Do not place the battery directly below the Victron MultiPlus
•  The appliance can be mounted horizontally as well as vertically; vertical mounting is preferable. The vertical 

position offers optimum cooling

•  Please note:  All aspects of the installation must be done without AC being connected to mains until all 

components of the system have been installed

•  The interior of the product must remain accessible after installation
•  Use only the DC cables supplied with the unit to minimize cable voltage losses
•  For safety purposes, this product should be not be installed close to chemicals, synthetic components, 

curtains or other textiles, etc

pum

p one

pum

p two

JOHN NEWTON

&  COM PANY LIM ITED  (EST.  1848)

CONTROL PANEL - PRO 2

WARNING

SHOC K HAZARD ISOLATE BOTH POWER SUPPLIES,

GRID MAINS AND BATTERY BAC K-UP POWER SUPPLY

BEFORE OPENING

YOUR COMPANY NAME &

LOGO ON PLATE FITTED

TO THIS RECESS

PUMP 1

RESET

& MUTE

PUMP 2

RESET

& MUTE

PUMP 1

PUMP 2

Newton Control Panel-Pro

MultiPlus 12/3000/120

VE.Net Blue Power Panel

VBC Battery Monitor Module

DC Battery

Dialer is mounted within

the control panel with

purchase code CP7

Main Float

Alarm

 Float

RJ45 (UTP cable)

VE Bus

VE.NET BLUE POWER PANEL

victron energy

Shunt 1/2000A 50mV

Bat -

Tem

p - & Tem

p +

RJ45

Shunt -

Shunt +

victron energy

VE.Net Battery Controller

www.victronenergy.com

Bat +

+

MultiPlus

12

charger

inverter

victron energy

B L U E  P O W  E R

A C transfer capacity: 1x 50  A  + 1X30A  Inverter 230V

battery charger

sinewave inverter

transfer switch

powerassist

parallel

connectable

three phase

connectable

mains on
bulk
absorption
float

Inverter on
overload
low battery
temperature

www.victronenergy.com

on
off
charge only

VOLT

3000  120

VA

AMP

Batt ery

B efore  charging   read the  i nstructi ons.   For  i ndoor  use  onl y. Disconnect

the suppl y before maki ng or breaki ng the connections to the battery.

WARNING:   E xplosive   gases,  prevent   flames  and   sparl s,  provi de

adequate  venti l ati on  duri ng  chargi ng.  Charge lead-acid or Li-lon batteries

onl y.

-

+

-

Pumps compatible with

MultiPlus 12/3000/120

CP750/NP750/SP750 Cutter

For Battery dimensions

please see drawings

prefixed Batt

For Battery dimensions

please see drawings

prefixed Batt

AC1

input

Grid input

connect to

AC1

output

The Victron MultiPlus 12/3000/120

battery back up system. Installed in

conjunction with Newton's System 500

pumping systems.

The Victron system provides an

Inverter/Charger function ensuring

water can still be removed in the event

of a power outage.

Additional batteries can be added of

varying sizes and power to provide

longer protection.

For Newton system 500 pumping

Specification's please contact

Newton's technical team on

01732 360095

 or enquire about using a

Newton specialist contractor.

In addition upgrades can be made to

offer extra peace of mind and further

reduce risk.

Newton Dialler - requires a BT

Telephone line.

Victron Battery monitor

Victron blue power panel

Newton System 500

Titan-Pro White Manual pumping

System  used with Newton System

500 waterproofing.

Section

To access the details mentioned above,

relevant NBS Clauses, product data and

MSDS sheets, please use this hyperlink:

Drawing Support

Checked by

Designed by

Date

Scale

Notes

Ref

Drawn by

Original Ref

NOTE: This is a waterproofing detail. For the design of the structure, please use a professional designer. We strongly recommend that Newton waterproofing systems are installed by our NSBC registered contractors who will guarantee,

                                                   insure and accept liability for both the design and the installation of our systems Please refer to product data sheets before installation of our products. John Newton reserves the right to update drawings.

NEWTON

Waterproofing Systems

17 - 19 Sovereign Way, Tonbridge, TN9 1RH

Tel: 01732 360095 Fax: 01732 359033

www.newton-membranes.co.uk - [email protected]

(EST. 1848)

Not to scale

29/04/2014

V3 - 01

AJB

XXX

AJB

INSTALLATION

INSTALLATION

Summary of Contents for Victron MultiPlus 12/3000/120

Page 1: ...NEWTON SYSTEM 500 System Sump and Pump VICTRON MULTIPLUS Installation Manual 12 3000 120 Rev 2 0 29 April 2016 Newton Waterproofing Systems Advanced Battery Back Up System...

Page 2: ...RE WARRANTY Products the supplier has not received payment for Normal wear tear Failure to follow product installation instructions and user instructions Usage that is not in accordance with the produ...

Page 3: ...TS PAGE INFORMATION 4 DIMENSIONS 4 SAFETY INSTRUCTIONS 4 INVERTER SIZING 5 TYPICAL DETAILS 5 INSTALLATION 6 QUICK INSTALL GUIDE 9 OPTIONAL CONNECTIONS 10 CONFIGURATION 10 BATTERY SELECTION 10 OPERATIO...

Page 4: ...s safety instructions WARNING DO NOT LIFT HEAVY LOADS WITHOUT ASSISTANCE INSTALLATION Read these installation instructions in full before installing the equipment This is a Safety Class I product supp...

Page 5: ...harge only VOLT 3000 120 VA AMP Batt ery Before charging read the i nstructi ons For i ndoor use onl y Disconnect the suppl y before maki ng or breaki ng theconnectionstothebattery WARNING Explosive g...

Page 6: ...able mains on bulk absorption float Inverter on overload low battery temperature www victronenergy com on off charge only VOLT 3000 120 VA AMP Batt ery Before charging read the i nstructi ons For i nd...

Page 7: ...B L U E P O W ER AC transfer capacity 1x 50 A 1X30A Inverter 230V battery charger sinewave inverter transfer switch powerassist parallel connectable three phase connectable mains on bulk absorption fl...

Page 8: ...oles using the screws provided Carefully mark out the hole centres then take the MultiPlus off the wall to drill the holes Note Rawl plugs will be required for the screws for certain wall types not su...

Page 9: ...neutral and L phase With its PowerAssist feature the Multi can add up to 3kVA that is 3000 230 13A to the output during periods of peak power requirement Together with a maximum input current of 16A t...

Page 10: ...a number of extra features over the Blue Power Panel such as Ethernet or Sim Card internet capability with remote monitoring via web portal and data storage on SD card Please refer to product install...

Page 11: ...powered by the mains through the MultiPlus Charger is about to change from Bulk to Absorption top up charge mode Power is interrupted Pumps are powered by the batteries through the inverter mains on b...

Page 12: ...minates MultiPlus is in Bulk protection mode thus the maximum bulk charging time of 10 hours is exceeded Such a long charging time could indicate a system error e g a battery cell short circuit Check...