In this scenario, temporarily set the network adapter of your computer to a static IP address such as
192.168.100.1, with a netmask of 255.255.0.0 and connect the Spark Plus.
Then run Studio Monitor on the computer, as described earlier to locate the unit. This will allow you to use
Spark‘s web page to set a suitable static IP of your choosing, following which you can restore the computer’s
normal network configuration settings.
1.4.4
NDI DECODING CONFIGURATION
Before using decoding function, please check the Ethernet IP address and log into the webpage for
management with this address, and then switch to decoding function.
Note: Encoding and decoding functions of the device cannot be carried out simultaneously. If the
devise is switched to decoding function, encoding function will be stopped. You will receive a pop-
up reminder before moving forward.
FIGURE 23