background image

SMC100CC & SMC100PP 

Controller GUI Manual 

 

1.4

 

Building the System 

Up to 

31

 

controllers

 can be networked through the internal RS-485 communication 

link. The first SMC100 is connected to the RS232 connector (address #1) which is 

connected to the computer and the others are linked with the RS485 connectors (address 

#2 to address #31).  
When the addresses of all controllers are set, you can build your system.  
Pull out all cables from all controllers. Set the dip switches of the controller with the 

address number 1 as FIRST. Set the dip switches of the other controllers, except one, as 

OTHERS, and set the dip switches of one controller as LAST. When you have only two 

controllers, one has to be set as FIRST (the one with the address number 1), and the 

other one as LAST. See below graphic for illustration. 

 

Connect the SMC100CC/PP configured as FIRST to the RS-232-C port or to the USB 

port of your PC. Connect a RS-485 network cable to the RS-485 OUT of the FIRST 

controller and to the RS-485 IN of the next controller. Proceed the same with all other 

controllers. When done, you can check your system: 

 

The controller configured as FIRST should have the RS-232-C cable connected to 

the computer. It has the 

address #1

 

All controllers configured as OTHERS should have one RS-485 network cable 

connected to the RS-485 IN and another one to the RS-485 OUT. 

 

The controller connected as LAST should have one RS-485 network cable 

connected to the RS-485 IN. 

Connect your stages to the SMC100CC/PP’s (MOTOR connector). Connect your 

SMC100CC/PP’s to power.  
The SMC100CC/PP allows chaining power from one SMC100CC/PP to another one 

using the SMC-PSC0.2 cable supplied with the controller. But the total power 

consumption of all stages connected to the same power supply should not exceed 80 W. 

The maximum power consumption of each Newport stage is listed in the Newport 

catalog and on the Newport web site. In case of questions, contact Newport. Once 

controllers have been networked the GUI can be used to switch between stages using 

the selected stage box. 
 

 

 

EDH0310En1030 – 01/17

 

Summary of Contents for SMC100CC

Page 1: ...Single Axis Motion Controller Driver for DC or Stepper Motor Controller GUI Manual V2 0 x SMC100CC SMC100PP...

Page 2: ...SMC100CC SMC100PP Controller GUI Manual EDH0310En1030 01 17 ii...

Page 3: ...allation 4 2 1 Install SMC100 Graphical User Interface 4 2 2 Launch GUI 4 3 0 Getting Started 5 3 1 Discover Instruments 5 4 0 User Interface 6 4 1 Configuration 6 4 2 Main 8 4 3 Jog 10 4 4 GPIO 11 4...

Page 4: ...SMC100CC SMC100PP Controller GUI Manual EDH0310En1030 01 17 iv...

Page 5: ...tructions on how to use the SMC100 Controller graphical user interface GUI 1 2 Overview The SMC100 Controller GUI is a graphical user interface that allows the user to interact with the SMC100CC or SM...

Page 6: ...MOVING Abort motion and then change to NOT REFERENCED state READY Change to NOT REFERENCED state DISABLE Change to NOT REFERENCED state Controller s LED display NOT REFERENCED If everything is OK the...

Page 7: ...e RS 485 OUT of the FIRST controller and to the RS 485 IN of the next controller Proceed the same with all other controllers When done you can check your system The controller configured as FIRST shou...

Page 8: ...tion folder selection By default it is showing C Click on Next Ready to install window opens up Click Install Then installation starts wait for completion Click on Finish to finalize the installation...

Page 9: ...tart the Controller GUI from Newport MotionControl SMC100 Next click on Discover button and the number of instruments discovered will appear This window allows the user to select a com port where the...

Page 10: ...troller GUI logs all the information Critical Error is the least detailed option of the settings When this setting is selected the Controller GUI will log errors that are defined to be critical only T...

Page 11: ...on PollingInterval The polling interval defines the number of milliseconds delay between each time the Controller GUI polls the instrument for the latest information An Integer 200 NbDigits Number of...

Page 12: ...e different controller states refer to the controller state diagram The second button Save Pos memorizes the current positions in the combo box As soon as a new position is memorized this is displayed...

Page 13: ...ed target position Motion Configuration Values In the Motion Configuration Values the current ends of run and the velocity are displayed in a disabled text box Minimum end of run Maximum end of run an...

Page 14: ...SMC100CC SMC100PP Controller GUI Manual 4 3 Jog Under this tab the controller allows the jog mode with use of two arrow buttons EDH0310En1030 01 17 10...

Page 15: ...Digital IO TTL outputs The four TTL outputs can be modified with a radio button ON OFF and are updated each time the polling interval expires TTL inputs The four TTL inputs are updated each time the p...

Page 16: ...oller GUI Manual 4 5 Parameters The Parameters tab allows the user to view or modify stage parameters for the selected controller A warning message is displayed as below Parameters page for a CC stage...

Page 17: ...rs from SmartStage button The Download parameters from SmartStage button downloads parameters from the SmartStage and saves them in its flash memory configuration parameters After the parameters have...

Page 18: ...l Set parameters button The Set parameters button modifies the configuration parameters 4 6 Address The Address tab allows two things 1 To scan and select connected SMC100 controllers 2 To configure a...

Page 19: ...I Manual 4 6 1 Controller pool setting Discover button The Discover button scans to find connected SMC100 controllers address 1 to address 31 After a Discover action the list of detected controllers i...

Page 20: ...ser to add a connected SMC100 controller to the list of Selected controllers After adding a detected controller the list of selected controllers is updated Delete button The Delete button deletes an S...

Page 21: ...the Set button A progress bar is displayed during the address configuration It is recommended to note the address of the controller somewhere For example use the stickers supplied with the SMC100CC P...

Page 22: ...mands and to view the history of commands that were sent and the responses that were received This list of commands and the syntax of each command can be found in the Command Interface User Manual A f...

Page 23: ...Controller GUI and the connected instruments It displays the Controller GUI name version and copyright information It also displays the instrument model the instrument key serial number or COM port t...

Page 24: ......

Page 25: ..._______________________________________________________ __________________________________________________________________________________________________________________ _____________________________...

Page 26: ...mail tech newport com Service RMAs Returns Tel 800 222 6440 e mail service newport com Europe MICRO CONTROLE Spectra Physics S A S 9 rue du Bois Sauvage 91055 vry CEDEX France Sales Tel 33 0 1 60 91 6...

Reviews: