How to operate the digital amplifier series NPCxxxDIG

 

8.1  Common Introduction 

 

Our line of digital piezo amplifiers d-Drive from 

Newport Corporation

 has now been expanded 

with  the  addition  of  the  OEM  amplifier  series 

NPCxxxDIG

  including

  NPC300DIG

  with  300mA 

output current. These amplifiers are designed for use as a single unit in industrial settings. It is 
compact,  robust,  and  mountable  in  different  manners  and  is  highly  reliable.  The 

NPCxxxDIG

 

was 

designed 

for 

universal 

use 

with 

wide 

main 

supply 

voltage 

from  

10V  to  30V  DC.  The  casing  is  available  in 

a screw  slot  version,  or for mounting  in a  19” rack 

mount casing. 
 
Piezo actuators can be controlled in three different ways, either by using the encoder knob on 
the front panel, by analog signal ranging from 0 to +10V, or by PC-Interface RS232. The best 
results for resolution and accuracy can only be achieved by setting the digital target values. The 
high  performance  of  the 

NPCxxxDIG

  with  20bit  effective  resolution  guarantees  the  customer 

high  speed  positioning,  with  the  highest  accuracy  available.  It  includes  rise  time  optimization 
and an active oscillation damping for every special application. 
 
The 

NPCxxxDIG

  comes  with  an  auto  calibration  routine  and  automatic  sensor  identification 

(ASI).  All  values  of  the  actuating  system,  like  capacitance,  measurement  system,  resonant 
frequency,  and  motion,  are  automatically  stored  in  the  amplifier.  An  automatic  amplifier 
optimization  occurs  after  actuator  identification.  All  this  makes  our  system  configuration  very 
easy and saves our customers a lot of time. 
 
A unique feature of the 

NPCxxxDIG

 is that it can be used in combination with strain gauge or 

capacitive feedback sensors without additional modification. The DSP (digital signal processor) 
runs at 64 MHz, and at a sampling rate of only 20 µsec. We have also implemented adjustable 
features such as slew rate, notch filter, and pass filters. A built-in function generator offers sine, 
triangular, and square functions, as well as noise and sweep. 
All operating elements are usable from the front side. The PC-interface on the back side allows 
wiring in switch cabinets. Extension cables for great distances are available.

 

8.2  User Elements / Connections 

8.2.1  Front panel 

 

Summary of Contents for NPC DIG Series

Page 1: ...n Manual Digital Piezo Amplifier Series NPCxxxDIG Models NPC50DIG NPC300DIG Please read carefully before switching on the power Please see safety instructions for using piezoelectric actuators and pow...

Page 2: ...www newport com 2 English version last change 2017 02 16 by TP...

Page 3: ...3...

Page 4: ...for checking the function of the system quick start 11 8 How to operate the digital amplifier series NPCxxxDIG 12 8 1 Common Introduction 12 8 2 User Elements Connections 12 8 2 1 Front Panel 12 8 2...

Page 5: ...rporation You will also find additional information regarding piezoelectric products Definition All systems from Newport Corporation such as electronics actuators and optical systems are called units...

Page 6: ...uction and form put by us into circulation is in accordance with all relevant essential requirements of the EMC Directive 2014 30 EU This declaration is no longer valid if the device is modified witho...

Page 7: ...l occur After excitation of the actuators by a voltage in the upper control range the ceramic will move and generate an opposite high voltage after disconnection Heating of the ceramic material will o...

Page 8: ...regular waste Instead it is the user responsibility to dispose of waste equipment according to the local laws The separate collection and recycling of the waste equipment at the time of disposal will...

Page 9: ...rs Only work with the units in a clean and dry environment Only specially prepared units e g actuators can work under other conditions Please only use original parts from Newport Corporation Newport C...

Page 10: ...cables e g power cords sensor cables actuator cables optical cables Do not block ventilated openings or place the units near a radiator oven or other heat sources Plug in the power cord completely so...

Page 11: ...r shape should be parallel each to each other and not have any scratches If there is any damage to the system please contact our local representative immediately If the packaging material is damaged p...

Page 12: ...high speed positioning with the highest accuracy available It includes rise time optimization and an active oscillation damping for every special application The NPCxxxDIG comes with an auto calibrati...

Page 13: ...13 8 2 2 Back Panel...

Page 14: ...www newport com 14 8 3 Function The following sketch shows the function groups of the amplifier sketch 1 function groups of the amplifier...

Page 15: ...akes for the output to get a certain value For a step input it is the time taken for the output to equal the input yi yi ki err Ts Ts 1 sample frequency 50 kHz 1 ki time constant yi output of i term I...

Page 16: ...er of magnitude While using open loop you can also switch on the notch filter to reduce stimulation of the resonant frequency Using the notch filter might increase noise The PID specific parameters kp...

Page 17: ...500Hz Actuator measurement connector PIEZO 15pin D Sub plug Monitor output 0 10V programmable signal source Monitor output impedance 1k Modulation input 0 10V disconnectable Modulation input impedanc...

Page 18: ...ription value monsrc value monitor output default 0 0 position value in closed loop 1 reference input 2 PID command voltage 3 closed loop deviation incl sign 4 closed loop deviation absolute 5 actuato...

Page 19: ...n loop position voltage back from the measured monitor voltage use the following formula Umes OL Umon 2 5V 2 The default setting is the position value in closed loop see No 0 sketch 3 monitor output 8...

Page 20: ...is connected to this plug The actuator voltage goes to the piezo the position signal from the measurement system goes to the DSP and the integrated actuator information is stored on an ID chip which g...

Page 21: ...ohm operation time of actuator since shipping minutes rgver version number of loop controller request table 6 commands without values commands with values command value Enter command description value...

Page 22: ...amplitude sine 0 to 100 gosin amplitude offset sine 0 to 100 gfsin generator frequency sine 0 1 to 9999 9 Hz gatri generator amplitude triangle 0 to 100 gotri amplitude offset triangle 0 to 100 gftri...

Page 23: ...rface every 500 milliseconds This value can then be read out via the interface Subsequent increasing of the query sequence for this value does not increase the refreshing rate If the piezoelectric act...

Page 24: ...11 10 9 211 210 29 0 0 0 generator off 0 0 1 sine on 0 1 0 triangle on 0 1 1 rectangle on 1 0 0 noise on 1 0 1 sweep on 0 512 1024 1536 2048 2560 12 212 0 notch filter off 1 notch filter on 0 4096 13...

Page 25: ...of the impulses trglen 1 or decrease the movement speed of the actuator Furthermore you must be sure that the trigger range between trgss and trgse passes through plus 0 2 of the total stroke otherwis...

Page 26: ...xt Trigger position is set to 10 m the trigger impulse will be generated when the 10 m position is reached from a lower position than 10 m rising edge Extended trigger functions trgedge 4 5 7 The func...

Page 27: ...ed This principle depends on whether or not trgss and trgse are bordered by a working area that crosses at least 0 2 of total stroke out of the borders trgss lower trigger position this is the lowest...

Page 28: ...triangle This will require that the relevant functional parameters be set frequency amplitude offset or symmetry The function generator does not need to be activated gfkt 0 To select a scan set the sc...

Page 29: ...combined use of trigger generation and scan function permits a highly exact scan of a probe Acceleration forces and with it oscillations are minimized by using a sine function and actions can be initi...

Page 30: ...OD input the actuator is in the most negative position pos 1 of its deviation pos 1 to pos 4 see sketch 2 By pressing the knob in the operation mode changes to closed loop and the OL CL LED changes to...

Page 31: ...onant frequency Use function generator in the menu of the actuator Set the amplitude to 5 the offset to 0 and the sweep time to 1 1sec decade Set the amplifier to open loop OL CL LED lights green With...

Page 32: ...justments reduce the ki value Reduce the kd value Check whether the function generator is still working read back parameters always deviate at the same level from the digital target value Please switc...

Page 33: ...ng in nm resolution you must warm up the amplifier 2 hours before use A constant temperature is beneficial Consider that a variation of 5 Kelvin results in elongation by 13 m in steel with a length of...

Page 34: ...www newport com 34 12 Your Notes...

Reviews: