9
2.4.1
Work area set up
•
Designate a work area that is clean and dry, with a cool
ambient temperature (up to 34 °C).
•
Locate the compressor on a flat level surface to ensure proper
pump lubrication and to prevent damage to the unit. Keep
12’’ of space around the unit to allow air circulation.
•
Intake air must be free from dirt, coarse solids, abrasive
particles and gaseous impurities.
•
Route the power cord properly to prevent tripping or exposing
the power cord to possible damage.
CAUTION
Be careful about high heat or high humidity conditions as you
will need to replace the filter and oil much more frequently.
2.4.2
Initial air compressor set up
WARNING
The compressor is shipped without oil. Please add oil before
use. Running the air compressor with the incorrect amount of oil
will cause damage to the unit and void the warranty. To prevent
damage, do not use with overfilled or low oil.
1)
Install the output air filter included with the air compressor unit by
tighten the attachment nut using 19 mm or adjustable spanner
wrench.
Figure : Install output air filter