4.7 INPUT SIGNAL INVERSION
Solder switches SWI and SW2 and the main PCB assembly (U0092) allow
the input data logic polarity to be inverted. It is applicable both for external
powered and 6155AS powered 2/20mA current loops
i.e. 2/20mA = LOGIC 1 = SPACE
0mA = LOGIC 0 = MARK
Follow the procedure below to select this feature if required.
PROCEDURE.
The procedure for all other aspects of configuration remain unchanged
.
1. Remove any connector(s) from the rear of the 6155AS
2. Remove the front panel lens
3. Remove the two size #8 case retaining screws from the rear of the
6155AS
4. The 6155AS meter can now slide forward out of its casing
5. Open-circuit solder-switch positions SWI-A and SW2-A
6. Short-circuit solder-switch positions SWI-B and SW2-B
7. Re-assemble the 6155AS meter now by reversing steps 1 to 4. above
Figure 1 Location of solder switches SW1 and SW2
Note.
The above configuration is only normally used for current loop operation. For
operation with other standard inputs (TTL, RS232, RS422, RS423 or
RS485) the solder switches SW1 and SW2 should be returned to the normal
configuration
.
Summary of Contents for 6155AS
Page 1: ...6155AS 6 DIGIT SERIAL INPUT REMOTE DISPLAY TYPE ...
Page 5: ...2 U02124ML 01 UK Figure 1 1 The 6155AS Block Diagram ...
Page 20: ...17 U02124ML 01 UK Figure 6 1 Case dimensions ...
Page 21: ...18 U02124ML 01 UK Figure 6 2 Main board display board assembly diagrams ...
Page 22: ...19 U02124ML 01 UK Figure 6 3 Main board schematic ...
Page 23: ...20 U02124ML 01 UK Figure 6 4 Display board schematic ...
Page 24: ...21 U02124ML 01 UK Figure 6 5 Power supply assembly diagram ...
Page 25: ...22 U02124ML 01 UK Figure 6 6 Power supply schematic ...
Page 26: ...23 U02124ML 01 UK Figure 6 7 DC Power supply schematic Option ...
Page 27: ...24 U02124ML 01 UK Figure 6 8 DC Power supply assembly option ...
Page 28: ...25 U02124ML 01 UK Figure 6 9 Exploded view of module ...
Page 31: ...28 U02124ML 01 UK NOTES ...