1.2 Safety Considerations
This device is marked with the
international caution symbol
. It is
important to read
this manual before installing or commissioning this
device as it contains important information relating to
Safety and EMC
(Electromagnetic Compatibility).
This instrument is a
panel mount device
protected in accordance with
Class II
of EN 61010 (115/230 ac power connections),
Class III
for the
low voltage power option (12 - 36 Vdc or 24 Vac). Installation of this
instrument should be done by a qualified personnel. In order to ensure
safe operation, the following instructions should be followed.
This instrument has
breaker
shall be included in the building installation as a disconnecting
device. It shall be marked to indicate this function, and it shall be in close
proximity to the equipment within easy reach of the operator. The switch
or circuit-breaker shall not interrupt the Protective Conductor (Earth wire),
and it shall meet the relevant requirements of IEC 947–1 and IEC 947-3
(International Electrotechnical Commission). The switch shall not be
incorporated in the main supply cord.
Furthermore, to provide protection against
excessive energy
being
drawn from the main supply in case of a fault in the equipment, an
overcurrent
protection device shall be installed.
•
Do not exceed voltage rating on the label located on the top of the
instrument housing.
•
Always disconnect power before changing signal and power
connections.
•
Do not use this instrument on a work bench without its case for safety
reasons.
•
Do not operate this instrument in flammable or explosive
atmospheres.
•
Do not expose this instrument to rain or moisture.
•
Unit mounting should allow for adequate ventilation to ensure
instrument does not exceed operating temperature rating.
•
Use electrical wires with adequate size to handle mechanical strain
and power requirements. Install without exposing bare wire outside
the connector to minimize electrical shock hazards.
EMC Considerations
•
Whenever EMC is an issue, always use shielded cables.
•
Never run signal and power wires in the same conduit.
•
Use signal wire connections with twisted-pair cables.
•
Install Ferrite Bead(s) on signal wires close to the instrument if EMC
problems persist.
Failure to follow all instructions and warnings may result in injury!