Newport Electronics 205-EC1 Operator'S Manual Download Page 23

X-ON Electronics

 

Largest Supplier of Electrical and Electronic Components
 
Click to view similar products for 

newport

 manufacturer:

 

Other Similar products are found below :  

BDS1

  

BDT1

  

WTK-14-36/N

  

5TC-TT-J-24-72

  

TXDIN70

  

OTP-U-F

  

5SC-TT-K-30-36

  

WTK-8-24/N

  

OTP-U-M

  

TPJ-U-F

  

5TC-TT-J-24-50/N

5SC-TT-T-30-72

  

SMTC-AL-P

  

SMPW-CC-T-M

  

MPJ-K-F-ROHS

  

Summary of Contents for 205-EC1

Page 1: ...359 7803 205 TC THERMOCOUPLE MINIATURE PANEL THERMOMETER Operator s Manual NEWPORT Electronics Inc M1189 N 0605 11231ML 02 Rev E For immediate technical or application assistance please call Newport...

Page 2: ...whole or in part without prior written consent of NEWPORT Electronics Inc Return Requests Inquiries Counters Frequency Meters PID Controllers Clock Timers Printers Process Meters On Off Controllers Re...

Page 3: ...ipment Required 18 4 2 Calibration Procedure 19 Section 5 Specifications 28 Section 6 Glossary 32 i T TA AB BL LE E O OF F C CO ON NT TE EN NT TS S S SE EC CT TI IO ON N P PA AG GE E Preface ii Models...

Page 4: ...to Table 1 3 for available choices Refer to Table 1 1 for the complete listing of models available ii PREFACE Manual Objectives This manual shows you how to set up and use the Panel Thermometer This...

Page 5: ...T C 1 0 C 205 TC2 T C 0 1 C 205 EF1 E F 1 0 F 205 EF2 E F 0 1 F 205 EC1 E C 1 0 C 205 EC2 E C 0 1 C 32 S SE EC CT TI IO ON N 6 6 G GL LO OS SS SA AR RY Y COMMON MODE REJECTION CMR a measure of the aff...

Page 6: ...0 F EF2 1 8 F 199 9 to 199 9 F 0 1 F EC1 1 5 C 105 to 1000 C 1 0 C EC2 1 0 C 199 9 to 199 9 C 0 1 C iv Table 1 2 O Ot th he er r M Mo od de el ls s A Av va ai il la ab bl le e Table 1 3 P Po ow we er...

Page 7: ...ces or practices that can effect the meter s functionality and must refer to accompanying documents 30 TOP VIEW SIDE VIEW 0 858 21 80 2 661 67 60 4 60 116 8 4 134 105 00 0 197 5 00 0 945 24 00 2 835 7...

Page 8: ...010 Equipment Class I per EN61010 Pollution Degree 2 per EN61010 Refer to the Glossary in Section 6 29 DISPLAY Type 7 segment LED Height 0 56 14 2 mm Symbols 1 8 8 8 Overrange Indication Three least s...

Page 9: ...1 Panel Thermometer with 3 small connectors plugged into the rear of the meter 1 Operator s Manual 28 S SE EC CT TI IO ON N 5 5 S SP PE EC CI IF FI IC CA AT TI IO ON NS S INPUT TYPE Thermocouple J K...

Page 10: ...F Zero 5 130 180 0 F Span EC1 0 0 0 C Zero 73 727 965 C Span EC2 0 0 0 5 C Zero 12 314 185 0 C Span 2 1 1 2 2 S SA AF FE ET TY Y C CO ON NS SI ID DE ER RA AT TI IO ON NS S This device is marked with t...

Page 11: ...andard 3 64 DIN Standard Panel Cutout Removable Screw Clamp Cable Connector Display Hold Capability 26 TABLE 4 2 CALIBRATION VALUES WHEN USING A MILLIVOLT SOURCE Look at the end of Table 4 2 for the e...

Page 12: ...JC1 in the model number set the millivolt source for 41 013 and the meter display should show 730 C 4 2 2 2 2 B Ba ac ck k o of f t th he e M Me et te er r Figure 2 2 illustrates the rear of the meter...

Page 13: ...your power requirement is 230 Vac solder jumper W2 should be wired but jumpers W1 and W3 should not 24 4 2 2 Calibrating using a Millivolt Source 1 Disconnect the power from the meter Remove the front...

Page 14: ...Zero 180 0 F 180 0 F Span EC1 0 C 0 C Zero 965 C 965 C Span EC2 0 C 0 5 C Zero 185 0 C 185 0 C Span 6 Voltage Jumper Pin Settings Figure 3 1 shows the location of solder jumpers W1 through W3 Figure 3...

Page 15: ...FOR C FOR F S3 S3 S3 P3 P1 W1 W2 W3 2 1 2 3 1 TRANSFORMER SPAN DISPLAY ZERO COMPONENT SIDE P2 2 3 1 22 TABLE 4 1 CALIBRATION VALUES WHEN USING THERMOCOUPLE CALIBRATOR Look at the end of Table 4 1 for...

Page 16: ...er adjusting the pots go back and verify both temperature readings Repeat steps 4 and 5 as required 8 S Se ec ct ti io on n 3 3 3 3 I In ns st ta al ll la at ti io on n a an nd d P Pa an ne el l M Mo...

Page 17: ...2 677 0 028 000 MOUNTING SCREW HOLES MOUNTING SCREW 2 MOUNTING CLAMP LENS CLAMP CLAMP SCREWS S1 S Z 20 2 Connect the thermocouple calibrator output signal to the thermocouple input connector P3 as sho...

Page 18: ...Figure 4 1 for the location of the calibration pots Figure 4 1 Calibration Potentiometers ZERO SPAN 10 3 3 4 4 S Se en ns so or r I In np pu ut t C Co on nn ne ec ct ti io on ns s Table 3 1 AMERICAN U...

Page 19: ...or on the meter Figure 3 4 Thermocouple Connector Wiring P3 1 2 TC INPUT Screws underneath TC INPUT 18 S SE EC CT TI IO ON N 4 4 O OP PE ER RA AT TI IO ON N A AN ND D C CA AL LI IB BR RA AT TI IO ON N...

Page 20: ...nstall the mounting clamp screws and lens PC BOARD PULL TAB HERE PUSH HERE P1 P2 P3 1 2 3 1 2 3 1 2 12 3 3 5 5 A An na al lo og g O Ou ut tp pu ut t C Co on nn ne ec ct ti io on ns s The analog output...

Page 21: ...the meter Figure 3 6 Display Hold Connections 1 2 3 RETURN Screws underneath Display Hold Switch P2 16 3 3 8 8 D Di is sa as ss se em mb bl ly y A As ss se em mb bl ly y You must go through the follow...

Page 22: ...Wiring P1 1 2 3 DC Screws underneath DC No Connection N C P1 ORANGE CONNECTOR External Power Supply 14 3 3 7 7 M Ma ai in n P Po ow we er r C Co on nn ne ec ct ti io on ns s Connect the ac main power...

Page 23: ...mponents Click to view similar products for newport manufacturer Other Similar products are found below BDS1 BDT1 WTK 14 36 N 5TC TT J 24 72 TXDIN70 OTP U F 5SC TT K 30 36 WTK 8 24 N OTP U M TPJ U F 5...

Reviews: