Safety
PAM.E4 manual
7
2
Safety
The
PAM.E4
must only be operated in perfect working condition in a proper manner, safely and in com-
pliance with the instructions, the valid accident prevention regulations and the guidelines of the local
power company.
The safety guidelines of the FST manual and the FST Installation and Commissioning manual apply
for this product.
2.1
Handling electronic assemblies
Electrostatic charging
›
Keep the electronic assembly in its original packaging until installation to prevent damage.
›
Before opening the original packaging, a static discharge must be performed!
To do this, touch a grounded piece of metal.
›
During work on electronic assemblies, periodically repeat this discharge procedure!
›
Equip all bus inputs/outputs not in use with a terminal resistor (terminator) to prevent malfunctions.
2.2
Residual dangers and protective measures
Dangerous electrical voltage!
In its installed state, the PAM.E4 is connected to the 230 V AC power supply.
Touching electrically live parts either directly or indirectly can result in an electric shock.
►
Take particular care when carrying out all work.