Exit Setup

 

 

 

Inquire the Product-Name of the Cradle 

 

 

Inquire the Wireless Module Information 

In order to inquire, the HR15 cradle information can feed back to the host by reading the setup barcode. 

 

Inquire the numbers of barcodes in memory 

 

 

 

Clear the barcodes in memory 

 

 

Inquire the State of the Wireless Module 

 

 

 

Summary of Contents for NLS-HR15XX-3E

Page 1: ...NLS HR15Series NLS HR15XX 3E Cordless 1D Barcode Scanner User Guide ...

Page 2: ...al product Regarding to the product modification and update FuJianNewland Auto ID Tech Co Ltd reserves the right to make changes to any software or product to improve reliability function or design at any time without notice This manual contains all the information is protected by copyright Any Company and individuals should not in any way or reason for any form of extract copy sell all or part of...

Page 3: ...Using RS232 Cable 6 Power on Power off Sleep Reboot 6 Power on 6 Power off 6 Sleep 6 Reboot 7 Reading Window Maintenance 7 Reading Depth of Field 8 8 Specification 9 Overview 10 Left View 10 Front View 10 Vertical View 10 CD15Ceadle Preview 11 Barcode Reading 11 Chapter 2 General Configuration 13 Introduction 13 Setting Barcode 13 Setting Command 13 Format of Setup Barcode 13 Use the Setting Barco...

Page 4: ...rary Mute 26 Chaper3 Inquiry Command 27 Introduction 27 Inquire the Cradle Information 27 Inquire the Wireless Module Information 28 Chapter 4 Communication Setup 29 HR15 Communication Mode Setup 29 Serial Port Setup 29 Baud Rate Setup 29 Check Setup 31 Stop Bit 31 Flow Control Setup 31 Data Bit 32 CD15 Cradle USB Function Setup 33 USB Virtual Keyboard Function 33 USB Virtual Serial Port Function ...

Page 5: ... Restore Default Value 42 Allow to Read UCC EAN 128 or not 42 Code ID Setup 42 Set the Barcode Reading Length 43 AIM 128 43 Restore Default Value 43 AIM 128 Allow to Read AIM 128 or not 44 Code ID Setup 44 Set the Barcode Reading Length 44 EAN 8 45 Restore Default Value 45 Allow to Read EAN 8 or not 45 Code ID Setup 46 Set Whether or not to Read 2 Digit Extracode 46 Set Whether or not to Read 5 Di...

Page 6: ...Extracode 54 Set Whether or not to Transmit the System Character 0 54 Extension Setup 54 UPC A 55 Restore Default Value 55 Allow to Read UPC A or not 55 CodeID Setup 55 Set Whether or not to Transimit the Check Digit 56 Set Whether or not to Transmit the System Digit 0 56 Set Whether or not to Read 2 Digit Extracode 56 Set Whether or not to Read 5 Digit Extracode 57 Interleaved 2 of 5 57 Restore D...

Page 7: ...5 66 CodeID Setup 66 Check Setup 67 Set the Barcode Reading Length 67 Industrial 25 68 Restore the Default Value 68 Allow to Read Deutsche 12 or not 68 CodeID Setup 68 Check Setup 69 Set the Barcode Reading Length 69 Standard 25 70 Restore the Default Value 70 Allow to Read Standard 25 or not 70 CodeID Setup 70 Check Setup 71 Set the Barcode Reading Length 72 Code 39 72 Restore the Default Value 7...

Page 8: ...t the Barcode Reading Length 82 Plessey 82 Restore the Default Value 82 Allow to Read Plessey or not 83 CodeID Setup 83 Check Setup 83 Set the Barcode Reading Length 84 MSI Plessey 85 Restore the Default Value 85 Allow to Read MSI Plessey or not 85 CodeID Setup 85 Check Setup 85 Set the Barcode Reading Length 86 GS1 Databar 87 Restore the Default Value 87 Allow to Read GS1 Databar or not 87 CodeID...

Page 9: ...CodeID Setup 89 Chapter 7 Appendix 90 Default Setup Table 90 AIM ID Table 99 CodeID Table 101 Data Barcode 102 Save and Abort the Setup 103 ...

Page 10: ......

Page 11: ...ation Setup Serial port parameter setup and USB function setup have been introduced in this chapter Chapter5 Data Format Introduces how to use the prefix and suffix to satisfy the customers requirement to obtaining more barcode data Chapter6 Barcode Parameter Setup In this chapter all the barcodes which HR15 scanner supports have been listed and the revelant parameter setup barcodes have been prov...

Page 12: ...d in this chapter with several pictures if your have a HR15 cordless scanner in your hand please compare the real scanner with this manual which will help you to understand this manulbetter This chapter is applicable to normal users maintenance staff and software developer Unpacking Open the package and take out HR15 cordless scanner and its accessories Please check the completeness of all the ite...

Page 13: ...ollowing picture Button Definition P Batch Transmission M Pair Search LED Indicator Definition Blue Wireless Network Green 4 Levels Power Indicator Communication mode There are 3 types of communication mode Synchronized Asynchronized factory default and Batch mode ...

Page 14: ...end back to the host PC when network recover again Batch mode Use the HR15 like data collector The barcode data will stored in flash memory after successful decoded And batch transfer to the host PC when put the HR15 on the cradle and pressed P button to start the transfer CD15 Cradle Interface Definition Pin assignment of CD15 connector PIN Definition Type Function 1 NC Null 2 NC Null 3 VCC P Pow...

Page 15: ...face on the host Please check the port on the host and purchase the right cable UsingUSB Cable Connect the CD15 crdle with host PC through USB cable 1 Plug the RJ45 connector into CD15 communication port 2 Plug the USB connector into host PC USB port ...

Page 16: ... on Power off Sleep Reboot Power on Connect the HR15 with the host the HR15 will power on automatically factory default Power off There is three ways to turn off the scanner Remove the cable connected from the HR15 Remove the cable connected from the Host PC Remove the power adapter connected from the RS232 cable Sleep The scanner will become into sleep mode if no scanning is carried out in a peri...

Page 17: ... should keep clean Avoid hard and rough objects to clean the reading window that will easy to cause the damage or scratch Use soft brush to remove the stain on the scanning window Please use the soft cloth to clean the window such as glassed cleaning cloth It is prohibited to spray liquid on the scanning window It is prohibited to use any detergent except for water ...

Page 18: ...8 Reading Depth of Field ...

Page 19: ... Weight of Cordless Scanner 210 g Including battery Weight of Cradle 150g Reminder Beep and LED indicator Power Adaptor Output DC5V 1 5A Input AC 100 240V 50 60Hz Environmental Operation Temperature 10 C to 50 C 14 F to 122 F Storage Temperature 20 C to 60 C 4 F to 140 F Humidity 5 95 non condensing Static Discharge 12 kV Air discharge 8 kV Direct discharge Drop 1 5 m drop to concrete Wireless Ope...

Page 20: ...ode height 11mm Testing distance 120mm Envirmenttemperature 23 Envirment light Illumination 200 LUX Overview Left View The picture below is the left view of HR15 scanner Front View The picture below is the front view of HR15 scanner Vertical View The picture below is the vertical view of HR15 scanner ...

Page 21: ...l keep a very high success ratio in certain distance which can be regarded as the optimal scanning distance order to find the optimal scanning distance When the scanner respond with a beep and the red illuminating line goes off it means the barcode reading is successful and the scanner will send the data to the host Note For the same batch of barcode the scanner will keep a very high success ratio...

Page 22: ...12 ...

Page 23: ... to setting the barcode engine In the following chapters in addition to setting code we will introduce the setting of the command string Notice All the setting command will keep in barcode engine except a few temporary setting commands will disappear after reboot or power off Format of Setup Barcode This is the sample of setup barcode The setup barcode label is consisted of three parts 1 The barco...

Page 24: ...ta barcode is the same with the settingcommand thus it is not necessary to scan the Exit Setup barcode to close the setup mode to keep it will not effect the normal operation Some functions may adjust the working parameters the numeric system of parameter is decimal or hexadecimal these values are entered by setting barcodes The data code in the appendix includes all the necessary numerical values...

Page 25: ... 99900030 5 The scanner will reply a success message by add in front of setting command and end by For example 99900030 6 The scanner also will reply anerror message by add in front of setting command and end by For example 99900030 7 The scanner will reply xxxxxxxx and contains in and the query results when you sending a query command For example Sending 99900301 query command for asking the firm...

Page 26: ...etting command contains parameters then the command will be combined according to the command system definition For example The combined command string which is stop by 0x0D and 0x0A The combined sending commands are 99904112 99900000 99900015 99900000 99900012 99900020 ...

Page 27: ... Start Setup Exit Setup 17 SetupProcess Flow ...

Page 28: ...ing the Restore to Factory Default barcode the scanner will restore the factory default Restore to Factory Default Work Mode Selection Power Off Reboot Test mode Note 1 Wake up the scanner please pressing trigger 2 The work mode is a temporarily setting the device will restore to the previous mode after reboot or power off ...

Page 29: ...es in sleep mode Auto power off after 60 minutes in sleep mode Never Power off Reading Mode Manual Scanning Mode Default setting the scanner will begin to read the barcode after the trigger is pressed it will stop after successful reading or if the trigger is loosed Manual Scanning The scanner can set the reading time in the manual scanning mode Set the Reading Time Note In the manual scanning mod...

Page 30: ...Not allowed to read the same barcoderepeatedly Allowed to read the same barcoderepeatedly Recounting after the read Allowed to Read the Same Barcode Repeatedly The scanner will begin the next barcode reading automatically after successful reading until the scanner trigger is pressed again Not Allowed to Read the Same Barcode Repeatedly The scanner will begin the next barcode reading automatically ...

Page 31: ...ode 3 Read the numeric 1 and 0 barcode 4 Read the Exit Setup barcode Sense Reading Mode The device do not need to trigger the scan and will auto detecting the scan environment changed to start to reading The reading finished device will turn to monitoring state to waiting for the next changes in the environment The surrounding environment sensor sensitivity can be setup During this mode click the ...

Page 32: ...ensitivity Setup in the Sense Mode It can be set in 16 levels from 0 to F the samller the value the higher the sensibility Example The steps of set the sensibility to level 5 1 Read the Start Setup barcode 2 Read the Custom Sensibility barcode 3 Read the numeric 5 barcode 4 Read the Exit Setup barcode Continuous Reading Mode The device going to continuous reading without triggered After successful...

Page 33: ...Extended Sense Reading In the extended sense reading mode the scanner can set the barcode reading time and the time intervals Set the Barcode Reading Time Set the Scanning Time Intervals In the extended sense reading mode the barcode reading time takes 2sec as the unit the parameter range is 0 30sec 0 means non stop The time interval takes 200ms as the unit the parameter ranges from 0 to 300ms Com...

Page 34: ...ils the scanner will send a symbol to describe that the reading is not successful Customer can set this symbol Set the Character to Describe Unsuccessful Reading Security Level Setup This value indicates the number of times to decode before correct reading of the confirmation code the higher value indicated the wrong decoded rate is lower and slower decode speed on the contrary faster the decode s...

Page 35: ... Decoding Audio Intermediate Frequency Weak High Frequency Laud Low Frequency Laud High Frequency Median Low Frequency Weak High Frequency Weak 150ms Sound Length Intermediate Frequency Laud 100ms Sound Length Intermediate Frequency Median 50ms Sound Length ...

Page 36: ... Start Setup 26 Exit Setup Other Setup Activate Abort Temporary Mute Active Temporary Mute Exit Temporary Mute ...

Page 37: ...e all the Information Inquire the Release Date Inquire the Firmware Information Inquire the Product Name Inquire the Serial Number Inquire the Cradle Information In order to inquire the CD15 cradle information can feed back to the host by reading the setup barcode Inquire all the Information Inquire the Firmware Information Inquire the Serial Number Inquire the Release Date ...

Page 38: ...Cradle Inquire the Wireless Module Information In order to inquire the HR15 cradle information can feed back to the host by reading the setup barcode Inquire the numbers of barcodes in memory Clear the barcodes in memory Inquire the State of the Wireless Module ...

Page 39: ...e barcode data will be stored in the FLASH if no network connection exists and the barcode data will be transmitted to the CD15 cradle when the network connection recovers Batch Mode the HR15 will immediately store the barcode data into FLASH no matter the network connection exists or not Put the scanner on the CD15 cradle press the button p to finish the batch transmission Synchronous mode Asynch...

Page 40: ... Start Setup 30 Exit Setup 9600 1200 2400 4800 14400 19200 38400 57600 115200 ...

Page 41: ... Start Setup Exit Setup 31 Check Setup No Check Even Check Odd Check Stop Bit 1 Stop Bit 2 Stop bits Flow Control Setup No Flow Control CTS Flow Control RTS Flow Control RTS_CTS Flow Control ...

Page 42: ...Check 1 Stop Bit 8 Data Bits Even Check 2 Stop Bit 8 Data Bits Even Check 1 Stop Bit 8 Data Bits Odd Check 2 Stop Bit 8 Data Bits Odd Check 1 Stop Bit 7 Data Bits Even Check 2 Stop Bit 7 Data Bits 7 Data Bits Odd Check 2 Stop Bit 7 Data Bits Even Check 1 Stop Bit 7 Data Bits Odd Check 2 Stop Bit ...

Page 43: ...al Keyboard Function USB Virtual Keyboard Function USB Virtual Serial Port Function USB Virtual Serial Port Function Keyboard Function Setup Keyboard Layout 1 st American English 7 th Italy 2 nd Japanese 8 th Norway 3 rd Danish 9 th Spanish 4 th Finland 10 th Turkey Q ...

Page 44: ...y between Characters The range of the delay time between characters is from 0 to 75 ms it takes 5ms as one level totally 15 levels The default value is 0ms Delay Setup Between Characters Character Conversion No Conversion All Lowercase Letter All Capital Letter Case the Opposite ...

Page 45: ...t these information may not be included in the barcode data Adding these information into the barcode will increase the barcode length and make it unflexible thus this method does not deserve recommendation Then we thought about to add something before or after the barcode data which can be added or shielded according to the requirement The things we add are the prefix and suffix of barcode data T...

Page 46: ...example set the custome prefix to CODE the hexadecimal value is 0x43 0x4F 0x44 0x45 1 Read the Start Setup barcode 2 Read the Set the Custom Prefix barcode 3 Read the following number code 4 3 4 F 4 4 4 5 4 Read the Save barcode 5 Read the Exit Setup barcode After the setup of it is allowed to add custom profix is finished by reading any barcode the scanner will add custom prefix character string ...

Page 47: ... invisible character or interpunction It is not Allow to Add CodeID Prefix Restore the Default CodeID Allow to Add CodeID Prefix Custom Suffix Add Custom suffix or Not The custom suffix will add the customer defined character string after the decoding information For example it is allowed to add custom suffix and set the suffix to character string AB by reading the barcode with data 123 the scanne...

Page 48: ...cter string AGE after the data End Mark Suffix Add End Mark Suffix or Not End mark suffix is used to declear the end of a intact data information which must be the last part of the data no other data will be added behind it The content decoding informatuon and prefix of custom suffix can be formated but the end mark suffix can not and this is the fundamental differences between end mark suffix and...

Page 49: ...he end mark of Windows Operation System to newline 1 Read the Start Setup barcode 2 Read the Set the End Mark Suffix barcode 3 Read the Set the end mark suffix to 0x0D 0x0A and make it can be sent 4 Read the Save barcode 5 Read the Exit Setup barcode After setup of it is allowed to add end mark suffix is finished by reading any barcode the scanner will add newline after the final data ...

Page 50: ...y reading the barcode the parameter setup of Code 128 will be restored to the factory default state Restore the Default Setup Value of Code 128 Allow to Read Code 128 or not Allow to Read Code 128 Prohibit Reading Code 128 Note the scanner will become unable to read Code 128 by reading the setup barcode Prohibit Reading Code 128 thus if the scanner is unable to read the Code128 please try to read ...

Page 51: ...d the barcode of Set the Maximum Length Limit to adjust the maximum length limit Set the Minimum Length Limit Set the Maximum Length Limit Note the maximum length limit of any 1D barcode must not exceed 255 if the maximum length is shorter than the minimum length then the scanner is only able to read the barcodes with the minimum length and the the maximum length if the maximum length equals to th...

Page 52: ...the scanner will become unable to read UCC EAN 128 by reading the setup barcode Prohibit Reading UCC EAN 128 thus if the scanner is unable to read the UCC EAN 128 please try to read the setuo barcode allow to read UCC EAN 128 Code ID Setup To activate the setup function by reading CodeID setup then read the hexadcimal value inaccordance with the character which will be set to the CodeID CodeID Set...

Page 53: ...ny 1D barcode must not exceed 255 if the maximum length is shorter than the minimum length then the scanner is only able to read the barcodes with the minimum length and the the maximum length if the maximum length equals to the minimum length then the scanner is only able to read the barcode with such length 示例 限制识度器只识读最小 8 字符 最大 12 字符的 UCC EAN 128 条码 Example Set the scannerread the UCC EAN 128 w...

Page 54: ...rdance with the character which will be set to the CodeID CodeID Setup Example Set the CodeID of AIM 128 to p the hexadcimal value is 0x70 1 Read the Start Setup barcode 2 Read the CodeID Setup barcode 3 Read the numeric barcode 7 0 see the appendix numeric barcode 4 Read the Save barcode see the appendix numeric barcode 5 Read the Exit Setup barcode Set the Barcode Reading Length The scanner is o...

Page 55: ...e to read the barcode with such length Example Set the scanner read the AIM128 with barcode length between 8 to 12 characters 1 Read the Start Setup barcode 2 Read the barcode of Set the Minimum Length Limit 3 Read the numeric barcode 8 see the appendix numeric barcode 4 Read the Save barcode see the appendix numeric barcode 5 Read the barcode of Set the Maximum Length Limit 6 Read the numeric bar...

Page 56: ...deID of EAN 8 to p the hexadcimal value is 0x70 1 Read the Start Setup barcode 2 Read the CodeID Setup barcode 3 Read the numeric barcode 7 0 see the appendix numeric barcode 4 Read the Save barcode see the appendix numeric barcode 5 Read the Exit Setup barcode Set Whether or not to Read 2 Digit Extracode 2 Digit extended code means to add 2 digit numeric barcode behind the normal barcode Do not r...

Page 57: ... Barcode Must Include 2 Digit Extracode the scanner is only able to read the 2 digits extracode Set Whether or not to Send the Check Digit The barcode data of EAN 8 is fixed in 8 characters the 8 th digit is the check digit for checking the correctness of the 8 characters Transmit the Check Bit Do not Transmit the Check Digit EAN 13 Restore Default Value By reading the barcode the parameter setup ...

Page 58: ... correctness of alll the 13 digit Send the Check Digit Send the Check Digit Code IDSetup To activate the setup function by reading CodeID Setup then read and save the hexadcimal value inaccordance with the character which will be set to the CodeID CodeID Setup Example Set the CodeID of EAN 13 to p the hexadcimal value is 0x70 1 Read the Start Setup barcode 2 Read the CodeID Setup barcode 3 Read th...

Page 59: ...code The Barcode Must Include 5 Digit Extracode Note By setting Allow to Read 2 Digit Extracode the scanner can read the new barcode consisted of normal barcode and extracode and the normal barcode without extracode By setting Do not read the 2 Digit Extracode the scanner can only read the normal barcode part of the new barcode the additional part of the new barcode which combines the normal barco...

Page 60: ...the Barcode into 13 Digit EAN 13 and lead by 0 Extend the Barcode and Transfer into EAN 13 ISSN Restore Default Value By reading the barcode the parameter setup of ISSN will be restored to the factory default state Restore the Default Setup Value of ISSN Allow to Read ISSN or not Allow to Read ISSN Prohibit Reading ISSN CodeID Setup To activate the setup function by reading CodeID setup then read ...

Page 61: ...tup barcode ISBN Restore Default Value By reading the barcode the parameter setup of ISBN will be restored to the factory default state Restore the Default Setup Value of ISSN Allow to Read ISBN or not Allow to Read ISBN Prohibit Reading ISBN Note the scanner will become unable to read ISBN by reading the setup barcode Prohibit Reading ISBN thus if the scanner is unable to read the ISBN please try...

Page 62: ... barcode 5 Read the Exit Setup barcode UPC E Restore Default Value By reading the barcode the parameter setup of UPC E will be restored to the factory default state Restore the Default Setup Value of UPC E Allow to Read UPC E or not Allow to Read UPC E Prohibit Reading UPC E Note the scanner will become unable to read UPC E by reading the setup barcode Prohibit Reading UPC E thus if the scanner is...

Page 63: ...f UPC Eto p the hexadcimal value is 0x70 1 Read the Start Setup barcode 2 Read the CodeID Setup barcode 3 Read the numeric barcode 7 0 see the appendix numeric barcode 4 Read the Save barcode see the appendix numeric barcode 5 Read the Exit Setup barcode Set Whether or not to Read 2 Digit Extracode 2 Digit extended code means to add 2 Digit numeric barcode behind the normal barcode Do not read the...

Page 64: ...he new barcode the additional part of the new barcode which combines the normal barcode and extended barcode can not be read By setting The Barcode Must Include 2 Digit Extracode the scanner is only able to read the 2 digits extracode Set Whether or not to Transmit the System Character 0 The first character of UPC E barcode is the system character the fixed value is 0 Extension Setup Do not Extend...

Page 65: ...UPC A Allow to Read UPC A or not Allow to Read UPC A Prohibit Reading UPC A Note the scanner will become unable to read UPC A by reading the setup barcode Prohibit Reading UPC A thus if the scanner is unable to read the UPC A please try to read the setuo barcode allow to read UPC A CodeID Setup To activate the setup function by reading CodeID setup then read the hexadcimal value inaccordance with ...

Page 66: ...ed of 13 digit the 13 rd digit is the check digit Send the Check Digit Do not Send the Check Digit Set Whether or not to Transmit the System Digit 0 The first character of UPC E barcode is the system Digit the value is 0 Do not Transmit System Character 0 Transmit System Character 0 Set Whether or not to Read 2 Digit Extracode 2 Digit extended code means to add 2 digit numeric barcode behind the n...

Page 67: ... only read the normal barcode part of the new barcode the additional part of the new barcode which combines the normal barcode and extended barcode can not be read By setting The Barcode Must Include 2 Digit Extracode the scanner is only able to read the 2 digit extracode Interleaved 2 of 5 Restore Default Value By reading the barcode the parameter setup of Interleaved 2 of 5 will be restored to t...

Page 68: ...racter Interleaved 2of 5 barcode data does not compulsively include the check digit if check digit exists then it is the last character Check digit is calculated according to all the datas for checking if the data is correct or not Set No Check the scanner will transmit all the barcode data Set Check but do not Send Check Digit the scanner will check according to the last bit if successful all the...

Page 69: ...ength Limit to adjust the maximum length limit Set the Minimum Length Limit Set the Maximum Length Limit Note the maximum length limit of any 1D barcode must not exceed 255 if the maximum length is shorter than the minimum length then the scanner is only able to read the barcodes with the minimum length and the the maximum length if the maximum length equals to the minimum length then the scanner ...

Page 70: ...ue is 0x70 1 Read the Start Setup barcode 2 Read the CodeID Setup barcode 3 Read the numeric barcode 7 0 see the appendix numeric barcode 4 Read the Save barcode see the appendix numeric barcode 5 Read the Exit Setup barcode ITF 14 TIF 14 is a knid of special Interleaved2 of 5 barcode with the barcode length of 14 characters and the last character as the check character By default no special proce...

Page 71: ... with Deutsch14 the ITF 14 will have priority to read CodeIDSetup To activate the setup function by reading CodeID setup then read the hexadcimal value inaccordance with the character which will be set to the CodeID CodeID Setup Example Set the CodeID ofITF 14to p the hexadcimal value is 0x70 1 Read the Start Setup barcode 2 Read the CodeID Setup barcode 3 Read the numeric barcode 7 0 see the appe...

Page 72: ...isunderstanding of function setup and decoding will easily occure thus it is suggested to turn off the Deutsche 14 if it is not in use CodeID Setup To activate the setup function by reading CodeID setup then read the hexadcimal value inaccordance with the character which will be set to the CodeID CodeID Setup Example Set the CodeID ofDeutsche14 to p the hexadcimal value is 0x70 1 Read the Start Se...

Page 73: ...uses the same coding method as ITF 12 and normal ITF so if all these are used at the same time the misunderstanding of function setup and decoding will easily occure thus it is suggested to turn off the Deutsche 12 if it is not in use CodeID Setup To activate the setup function by reading CodeID setup then read the hexadcimal value inaccordance with the character which will be set to the CodeID Co...

Page 74: ...e Prohibit Reading UCC EAN 128 thus if the scanner is unable to read the COOP25 please try to read the setuo barcode allow to read COOP25 CodeID Setup To activate the setup function by reading CodeID setup then read the hexadcimal value inaccordance with the character which will be set to the CodeID Example Set the CodeID ofCOOP25to p the hexadcimal value is 0x70 1 Read the Start Setup barcode 2 R...

Page 75: ...Note by setting do not send the check digit if the data length except for the 1 character check digit is less than the minimum barcode reading limit the barcode reading will be failed For example the scanner set the the minimum barcode reading length of COOP25 JapaneseMatrix2 of 5 to 4 characters and do not send check digit in such circumstances the scanner is not able to read the Deutsch12 with 4...

Page 76: ...Matrix2 of 5 Prohibit Reading Matrix2 of 5 Note the scanner will become unable to read Matrix2 of 5 by reading the setup barcode Prohibit Reading Matrix2 of 5 thus if the scanner is unable to read the Matrix2 of 5 please try to read the setuo barcode allow to read Matrix2 of 5 CodeID Setup To activate the setup function by reading CodeID setup then read the hexadcimal value inaccordance with the c...

Page 77: ... Check Check and Send Check digit Check but do not Send Check digit Note by setting do not send the check digit if the data length except for the 1 character check digit is less than the minimum barcode reading limit the barcode reading will be failed For example the scanner set the the minimum barcode reading length of Matrix2 of 5 to 4 characters and do not send check digit in such circumstances...

Page 78: ...default state Restore the Default Setup Value of Industrial 25 Allow to Read Deutsche 12 or not Allow to Read Industrial 25 Prohibit Reading Industrial 25 Note the scanner will become unable to read Industrial 25 by reading the setup barcode Prohibit Reading Industrial 25 thus if the scanner is unable to read the Industrial 25 please try to read the setuo barcode allow to read Industrial 25 CodeID...

Page 79: ...eck digit will be treated as the last bit of the normal data if failed then the scanner will indicate barcode reading failed No Check Check and Send Check digit Check but do not Send Check digit Note by setting do not send the check digit if the data length except for the 1 character check digit is less than the minimum barcode reading limit the barcode reading will be failed For example the scann...

Page 80: ... the Default Value By reading the barcode the parameter setup of Standard 25 will be restored to the factory default state Restore the Default Setup Value of Standard 25 Allow to Read Standard 25 or not Allow to Read Standard 25 Prohibit Reading Standard 25 Note the scanner will become unable to read Standard 25 by reading the setup barcode Prohibit Reading Standard 25 thus if the scanner is unabl...

Page 81: ...ing to the last bit if successful all the data except for the check digit will be transmitted if failed then the scanner will indicate barcode reading failed Set Check and Send Check digit the scanner will check according to the last bit if successful all the data including the check digit will be transmitted the check digit will be treated as the last bit of the normal data if failed then the sca...

Page 82: ...y 1D barcode must not exceed 255 if the maximum length is shorter than the minimum length then the scanner is only able to read the barcodes with the minimum length and the the maximum length if the maximum length equals to the minimum length then the scanner is only able to read the barcode with such length Code 39 Restore the Default Value By reading the barcode the parameter setup of Code 39 wi...

Page 83: ...a Set Check but do not Send Check digit the scanner will check according to the last bit if successful all the data except for the check digit will be transmitted if failed then the scanner will indicate barcode reading failed Set Check and Send Check digit the scanner will check according to the last bit if successful all the data including the check digit will be transmitted the check digit will...

Page 84: ...off the Function of Reading Full ASCII Turn on the Function of Reading Full ASCII Set the Barcode Reading Length The scanner is only able to read the Code 39 with tramsmission content length falls in the limited range the range is consisted of the maximum value and minimum value in units of character the Code 39 exceeds the range can not be read or transmitted Read the barcode of Set the Minimum L...

Page 85: ... Read the numeric barcode 2 8 Read the Save barcode see the appendix numeric barcode 9 Read the Exit Setup barcode Codabar Restore the Default Value By reading the barcode the parameter setup of Codabar will be restored to the factory default state Restore the Default Setup Value of Codabar Allow to Read Codabar or not Allow to Read Codabar Prohibit Reading Codabar Note the scanner will become una...

Page 86: ...ast bit if successful all the data except for the check digit will be transmitted if failed then the scanner will indicate barcode reading failed Set Check and Send Check digit the scanner will check according to the last bit if successful all the data including the check digit will be transmitted the check digit will be treated as the last bit of the normal data if failed then the scanner will in...

Page 87: ...e barcode of Set the Minimum Length Limit to adjust the minimum length limit Read the barcode of Set the Maximum Length Limit to adjust the maximum length limit Set the Minimum Length Limit Set the Maximum Length Limit Note the maximum length limit of any 1D barcode must not exceed 255 if the maximum length is shorter than the minimum length then the scanner is only able to read the barcodes with ...

Page 88: ...ate Restore the Default Setup Value of Code 93 Allow to Read Code 93 or not Allow to Read Code 93 Prohibit Reading Code 93 Note the scanner will become unable to read Code 93 by reading the setup barcode Prohibit Reading Code 93 thus if the scanner is unable to read the Code 93 please try to read the setuo barcode allow to read Code 93 CodeID Setup To activate the setup function by reading CodeID ...

Page 89: ...eck digit will be treated as the last bit of the normal data if failed then the scanner will indicate barcode reading failed No Check Check and Send Check Digit Check but do not Send Check Digit Note by setting do not send the check digit if the data length except for the 1 character check digit is less than the minimum barcode reading limit the barcode reading will be failed For example the scann...

Page 90: ...ading the barcode the parameter setup of Code 11 will be restored to the factory default state Restore the Default Setup Value of Code 11 Allow to Read Code 11 or not Allow to Read Code 11 Prohibit Reading Code 11 Note the scanner will become unable to read Code 11 by reading the setup barcode Prohibit Reading Code 11 thus if the scanner is unable to read the Code 11 please try to read the setuo b...

Page 91: ...r not Set No Check the scanner will transmit all the barcode data No Check One Digit Check MOD11 Two Digits Check MOD11 MOD11 Two Digits Check MOD11 MOD9 MOD11 Single Check Len 10 MOD11 MOD11 Double Check Len 10 MOD11 Single Check Len 10 MOD11 MOD9 Double Check Len 10 Do not Send the Check Digit Send the Check Digit Note by setting do not send the check digit if the data length except for the 1 ch...

Page 92: ... maximum length is shorter than the minimum length then the scanner is only able to read the barcodes with the minimum length and the the maximum length if the maximum length equals to the minimum length then the scanner is only able to read the barcode with such length Example The steps of set the scanner read the Code 11 with barcode length between 8 to 12 characters 1 Read the Start Setup barco...

Page 93: ...ic barcode 7 0 see the appendix numeric barcode 4 Read the Save barcode see the appendix numeric barcode 5 Read the Exit Setup barcode Check Setup Plessey barcode data does not compulsively include the check digit if check digit exists then it is the last character Check digit is calculated according to all the datas for checking if the data is correct or not Set No Check the scanner will transmit...

Page 94: ... range the range is consisted of the maximum value and minimum value in units of character the Plessey exceeds the range can not be read or transmitted Read the barcode of Set the Minimum Length Limit to adjust the minimum length limit Read the barcode of Set the Maximum Length Limit to adjust the maximum length limit Set the Minimum Length Limit Set the Maximum Length Limit Note the maximum lengt...

Page 95: ...etup To activate the setup function by reading CodeID setup then read the hexadcimal value inaccordance with the character which will be set to the CodeID Code ID Setup Example Set the CodeID ofMSI Plesseyto p the hexadcimal value is 0x70 1 Read the Start Setup barcode 2 Read the CodeID Setup barcode 3 Read the numeric barcode 7 0 see the appendix numeric barcode 4 Read the Save barcode see the ap...

Page 96: ...he scanner is not able to read the MSI Plessey with 4 characters Set the Barcode Reading Length The scanner is only able to read the MSI Plessey with tramsmission content length falls in the limited range the range is consisted of the maximum value and minimum value in units of character the MSI Plessey exceeds the range can not be read or transmitted Read the barcode of Set the Minimum Length Lim...

Page 97: ...ibit Reading GS1 Databar Note the scanner will become unable to read GS1 Databar by reading the setup barcode Prohibit Reading GS1 Databar thus if the scanner is unable to read the GS1 Databar please try to read the setuo barcode allow to read GS1 Databar CodeID Setup To activate the setup function by reading CodeID setup then read the hexadcimal value inaccordance with the character which will be...

Page 98: ...able to read the PDF417 please try to read the setuo barcode allow to read PDF417 Note PDF417 can support the barcode with maximum 48 lines x 18 rows CodeID Setup To activate the setup function by reading CodeID setup then read the hexadcimal value inaccordance with the character which will be set to the CodeID Code ID Setup Example Set the CodeID ofPDF417to p the hexadcimal value is 0x70 1 Read t...

Page 99: ...he scanner is unable to read the MicroPDF417 please try to read the setuo barcode allow to read MicroPDF417 Note MicroPDF417 support the barcode with maximum 255 bytes CodeID Setup To activate the setup function by reading CodeID setup then read the hexadcimal value inaccordance with the character which will be set to the CodeID Code ID Setup Example Set the CodeID ofMicroPDF417to p the hexadcimal...

Page 100: ...Range 0 15sec 0 means non stop Set the Time Interval between Scanning 1 second Range 0 7 5sec Sensitivity Level High Sensibility Effective in Sensitivity Mode Security Level Level 1 Decoding Sound Intermediate Frequency Loud 150ms Tone fo Successful Reading Read the Same Barcode successivly Off Effective in Auto Mode Re Timing after Successful Reading On Effective in Auto Mode Communication Setup ...

Page 101: ...Off Data Format Setup Setup of the Prefix sequence CodeID Custom AIMID CodeID Prefix AIMID Data Suffix Terminal Add AIMID Prefix Off Cm Symbol Add CodeID Off 1 or 2 Character Captital or Lowercase Letter Add Custom Prefix Off The Maximum is 11 characters Add Custom Suffix Off The Maximum is 11 characters Barcode Parameter Setup Code128 Enable On Maximum Length 255 Minmum Length 1 UCC EAN 128 Enabl...

Page 102: ...Off Read 5 Digits Extracode Off Extracode is Required 2 digits Off Extracode is Required 5 digits Off Extend to EAN 13 Off Type is EAN 13 when Extend Off EAN 13 Enable On Send the Check Character On Read 2 Digits Extracode Off Read 5 Digits Extracode Off Extracode is Required 2 digits Off Extracode is Required 5 digits Off ISSN Enable Off ISBN Enable Off ...

Page 103: ...e is Required 2 digits Off Extracode is Required 5 digits Off Extend to UPC A Off Type is UPC A when Extend Off Send the System Digit 0 UPC A Enable On Send the Check Character On Read 2 Digits Extracode Off Read 5 Digits Extracode Off Extracode is Required 2 digits Off Extracode is Required 5 digits Off Send the System Digit 0 Interleaved 2 of 5 Enable On Check On Send Check Character Off ...

Page 104: ...end Check Character On ITF 14 Enable Off Send Check Character On Deutshe 14 Enable Off Send Check Character On Deutshe 12 Enable Off Send Check Character On COOP25 JapaneseMatrix 2 of 5 Enable Off Check Off Send Check Character Off Maximum Length 255 Minmum Length 6 Matrix 2 of 5 European Matrix 2 of 5 Enable On ...

Page 105: ...h 6 At less 3 Industrial 25 Enable Check Send Check Character Maximum Length Minmum Length Standard 25 Enable On Check Off Send Check Character Off Maximum Length 255 Minmum Length 6 At less 4 Code 39 Enable On Check Off Send Check Character Off Do not Send Start and Stop Character Off Support Full ASCII On Maximum Length 255 ...

Page 106: ...ff Select one ABCD ABCD as the Start and Stop Character On ABCD TN E as the Start and Stop Character Off abcd abcd as the Start and Stop Character Off abcd tn e as the Start and Stop Character Off Maximum Length 255 Minmum Length 4 At less 2 Code 93 Enable On Check On Send Check Character Off Maximum Length 255 Minmum Length 2 At less 1 Code 11 Enable Off Check Off ...

Page 107: ...its MOD11 MOD11 Off Auto 2 Digits MOD11 MOD9 Off Maximum Length 255 Minmum Length 4 At less 3 Plessey Enable Off Check On Send Check Character Off Maximum Length 255 Minmum Length 4 At less 4 MSI Plessey Enable Off Check Off Send Check Character On 1 Digit MOD10 Check Off 2 Digits MOD10 MOD10 Check Off 2 Digits MOD10 MOD11 Check Off Maximum Length 255 Minmum Length 4 At less 3 ...

Page 108: ... Start Setup 98 Exit Setup Parameters Default Setup Remark GS1 Databar Enable On PDF417 Enable On MicroPDF417 Enable On ...

Page 109: ...IM 128 C2 ISBT 128 C4 EAN 8 E4 EAN 13 E0 EAN 13 with Addon E3 ISSN X0 ISBN X0 UPC E E0 UPC E with Addon E3 UPC A E0 UPC A with Addon E3 Interleaved 2 of 5 Im 0 1 3 ITF 6 Im 1 3 ITF 14 Im 1 3 Deutsche 14 X0 Deutsche 12 X0 COOP 25 Japanese Matrix 2 of 5 X0 Matrix 2 of 5 European Matrix 2 of 5 X0 Industrial 25 S0 ...

Page 110: ... 2 4 Code 93 G0 Code 11 Hm 0 1 3 Plessey P0 MSI Plessey Mm 0 1 GS1 Databar e0 PDF417 Lm 0 1 2 MicroPDF417 Lm 3 4 5 Reference 1 ISO IEC 15424 2008 2 Information Technology Auto Identification and Data Cellection Technology Data Carrier Identifiers including the symbol identifiers ...

Page 111: ...C EAN 128 u AIM 128 f ISBT 128 t EAN 8 g EAN 13 d ISSN n ISBN B UPC E h UPC A c Interleaved 2 of 5 e ITF 6 r ITF 14 q Deutsche 14 w Deutsche 12 l COOP 25 Japanese Matrix 2 of 5 o Matrix 2 of 5 European Matrix 2 of 5 v Industrial 25 i Standard 25 s Code 39 b Codabar a Code 93 y ...

Page 112: ...p 102 Exit Setup Code 11 z Plessey p MSI Plessey m GS1 Databar R PDF417 P MicroPDF417 M Data Barcode After reading the data barcode please read save in the next page to svae the data barcode setup 0 4 1 5 2 6 3 7 ...

Page 113: ...nner has read a centain setup barcode and read numeric data 1 2 3 according to priority after that If the scanner read Abort the Last Data then the last digit 3 will be aborted if read Abort a String of Data then the data 123 will be aborted if read Abort the Present Setup then the data 123 and the setup barcode will all be aborted and the scanner is still in the state of Enter Setup Barcode Save ...

Page 114: ... Start Setup 104 Exit Setup Abort one of the Presnet Setup of the Data Parameter Abort one of the Presnet Setup of the Data Parameter ...