background image

 

5. Operation Instructions 

Never operate your night vision device at daylight 

without the lens cover on. Never direct the lens towards 

bright light. 

5.1.

 

Operation 

Once in dark environment, take off the lens caps (4). 
Operation without the lens cover on is acceptable only at the 
illumination level below 1 lux. At such illumination a 
person with normal vision can read a newspaper with 
difficulty after 5-10 minutes of eyes’ adaptation. 
Check the functioning of the device by switching it on: push 
activation lever (5) towards the body of the unit and look 
through the eyepiece (3). You should see a greenish-lit 
screen. Rotate eyepiece (3) to focus. In order to focus on a 
different distance, rotate the objective lens (2). 

5.2.

 

Lever  

Proper operation of the activation lever: Push it down and 
hold in this position. This should provide 30-60 seconds of 
operation. Once the screen begins to dim, boost the image 
by releasing the handle and pushing it down again after a 
few seconds (not immediately!).  
Pumping the lever up and down rapidly will deactivate the 
power mechanism for 15-30 minutes. 

Summary of Contents for STARGATE M

Page 1: ...OPERATION MANUAL NIGHT VISION MONOCULAR STARGATE M 105 Sparks Ave Toronto ON M2H 2S5 Canada...

Page 2: ......

Page 3: ...nit in daylight At daytime objective lens must be covered by caps There is a tiny hole in the cap to provide enough light for day time operation NEVER aim active unit at intense light sources i e ligh...

Page 4: ...1 Table of contents 1 Overview 2 2 Delivery Set 5 3 Specifications 6 4 Design 7 5 Operation Instructions 8 6 Troubleshooting 10 7 Warranty 12 8 Customer Support 12 9 Acceptance Certificate 15...

Page 5: ...t The Stargate M utilizes piezo crystals as a source of high voltage power for the image intensifier tube The unit does not need any batteries to operate An additional infrared illuminator is powered...

Page 6: ...onnections Due to considerable optical magnification of the eyepiece some small structures inside the tube coating in the form of dark and or white points may be seen in the field of view this does no...

Page 7: ...llumination from 5 1000 lux to 1 lux High quality wide angle lens The internal focusing mechanism provides a wide focusing range Soft rubber eye cap blocks disturbing lateral light and protects from l...

Page 8: ...5 2 Delivery Set Stargate M is supplied with the following components Quantity Stargate M 1 AP 12 IR illuminator 1 Neck strap 1 Case 1 Manual 1 Warranty Registration Card 1...

Page 9: ...ce focal length mm 9 5 Power Supply Monocular needs no batteries IR illuminator CR 123 Environmental conditions Operation temperature range Relative humidity of no more than 25 C to 40 C 80 at 20 C Di...

Page 10: ...7 4 Design Figure 1 1 Housing 2 Lens 3 Eyepiece 4 Lens Cover 5 Activation lever 6 Screw Cover 7 Pressure Adjustment Screw 8 Bushing 9 Infrared Illuminator 10 IR illuminator battery house cover...

Page 11: ...ck the functioning of the device by switching it on push activation lever 5 towards the body of the unit and look through the eyepiece 3 You should see a greenish lit screen Rotate eyepiece 3 to focus...

Page 12: ...dampened with lens cleaner obtained from any camera store Clean the lens surface carefully with circular movements starting from the center 5 5 Boosting image brightness After a long period of use th...

Page 13: ...e object The image doesn t appear in focus Bring the inspected object if the view still does not seem in focus clean the lenses they could be foggy or dusty 6 3 Image flashes It is normal for the unit...

Page 14: ...ospheric conditions such as fog haze or extremely dark environments will decrease the visibility distance as well 6 6 Visible spots Image quality of the object which is being observed when an image in...

Page 15: ...1 From 0 150 to 0 294 From 0 073 to 0 150 From 0 150 to 0 294 From 0 294 to 0 400 Up to 0 073 From 0 073 to 0 150 From 0 150 to 0 294 7 Warranty NEWCON warrants this product against defects in materi...

Page 16: ...ce other than by a NEWCON Authorized Service Postage insurance and shipping costs incurred while presenting your NEWCON product for warranty service are your responsibility If shipping from North Amer...

Page 17: ...lity for unauthorized returns To locate NEWCON Authorized Dealer call Tel 416 663 6963 Fax 416 663 9065 Email newconsales newcon optik com Web www newcon optik com The defective products should be shi...

Page 18: ...te M Serial number _________________________________ Complies with all technical specifications and has passed the inspection Date of production _________________________________ Quality Inspector ___...

Page 19: ......

Page 20: ...NEWCON OPTIK Printed in Canada...

Reviews: