Newcon Optik LRB 20 Operation Manual Download Page 6

                                                                           Table 4.1, continued 

Description Designation 

Qnty 

Serial  

No. 

Remar

ks 

19. Cable 
20. Eraser 
21. Cloth 
22. Charging  device 
23. Protection device 
 

Materials 

 

24. Silica gel, indicating 
      GOST 8984-75 
 

Package 

 
25. Package 
26. Package 
27. Package 
28. Casing 
29. Casing  
30. Cover 
31. Cover 
32. Cover 
 

Documents 

 

33. Operating 
      instructions 

 

AEP 48.44.120 

 

G61.93.516 

AEP 43.79.608 
AEP 43.79.607 

 
 
 
 
 
 
 
 

AEP 42.86.186 
AEP 42.83.368 
AEP 42.86.184 

G 42.62.345 

AEP 45.71.018 
AEP 42.63.021 
AEP 42.63.030 

G 42.63.332 

 
 
 

AEP 36.28.001 

Р





 
 
 

50 g 

 
 
 
 








 
 
 

 

 

 

 

 

5. APPEARANCE OF THE DEVICE

 

 

5.1.

 As  it  is  set up for  operation,  binoculars  range  finder  LRB 20 

000 (see Fig.1) is essentially range finder 

mounted on Angular Mount 

. The latter is mounted on tripod 

3

5.1.1.

 Range finder (Fig.2) is intended for terrain observation and 

measuring the distance to the closest or next-in range target caught in 
the beam. 
 

The range finder works on the principle of measuring the light 

pulse round-trip time. 
 

The measurement result is displayed in metres on digital range 

indicator and also stored in the computer in binary code for further 
calculations. 
 

The schematic circuit diagram of range finder (Fig.3) shows 

Rechargeable battery designated (G1), controls designated (S1- S4), 
pumping and firing elements (ref. designations C1-C3, E1, L1, T1, V1-
V2), control circuit board (A1), display circuit board (A2), counter 
circuit board (A3), and photodetector assembly (A4). 
 

Toggle switch S1 is operated to energize the range finder, and 

toggle switch S4 – to light up the light-emitting diode (LED) H1 which 
illuminates the reticle pattern. 
 

Button switches S2 and S3 labelled (MEASURE 1) and 

(MEASURE L) respectively are used to prepare the range finder for 
taking a measurement (by depressing one of those buttons), and to 
perform the measuring operation (for which the button is released). 
 

Button S2 is operated to range the closest target, whereas 

button S3 is used to engage the next-in-range target caught in the beam. 
 

Summary of Contents for LRB 20

Page 1: ...d NEVER subject the unit to impact while operating or being transported NEVER aim the unit at the sun NEVER measure ranges to mirror reflecting surfaces NEVER touch optical surfaces with fingers NEVER...

Page 2: ...NGE FINDER BINOCULARS LRB 20 000 is an advanced Laser Range Finder system that provides instant distance measurements consistently and accurately The stereoscopic device provides convenient observatio...

Page 3: ...om temperature for at least two hours before unpacking and then mop up the condensed moisture while operating the range finder at temperatures above 35 C and exposing to direct sunrays attach cover AE...

Page 4: ...e between 40 and 50 C relative air humidity of up to 98 as taken at 35 C air pressure of 61 kPa 460 mm Hg minimum and in the sea mist conditions 2 5 Power to the range finder is supplied from recharge...

Page 5: ...Table 4 1 Description Designation Q ty Serial No Remarks 1 Range finder 2 Tripod optional 3 Angular Mount optional 4 Rechargeable battery 5 Fuse link VP1 1 1 0 A 250 V 6 Sealing ring 7 Framed lens 8...

Page 6: ...beam The range finder works on the principle of measuring the light pulse round trip time The measurement result is displayed in metres on digital range indicator and also stored in the computer in bi...

Page 7: ...ount Fig 4 is intended for mounting range finder on a tripod to lay the range finder on the target and to read the azimuth and elevation The Angular Mount AI is essentially body 15 which incloses the...

Page 8: ...tical components grinded and polished surfaces which are nearer to range finder than 1700 m direct radiation to diffuse reflecting surfaces walls curtains papers which are nearer to range finder than...

Page 9: ...isplayed in all the digit positions and the decimal point in the third position 7 4 To use AI and tripod for observation proceed as follows Arrange the tripod on selected site Extend the telescoping l...

Page 10: ...small size things flash light knife screwdriver etc are 20 cm away from the instrument 7 6 To check the range finder for proper operation when using the AI and the tripod check the AI zero elevation r...

Page 11: ...hen ranging fixed targets proceed as follows set the ON OFF selector switch to the ON position lay the range finder on the target so that the latter or its visible portion is observed in the central g...

Page 12: ...f the reticle is 0 05 mils large division value is 0 10 mils 8 6 To measure vertical and elevation angles proceed as follows align the horizontal mark of the range finder Binocular reticle with the up...

Page 13: ...drawn line Mark the obtained OP location point on the circular scale adjust the circular to read the directional angle as determined for the target from observation post pass a vertical line from bott...

Page 14: ...range finder Binocular reticle is illuminated Measurement results are within 5 m of predetermined range or on another ER O error determined for vertical angle scale is to be reckoned in while measurin...

Page 15: ...y In service maintenance is performed every six months and before placing the range finder in short term storage 10 3 Check Inspection 10 3 1 During the check inspection is ascertained the serviceable...

Page 16: ...dividual SPTA set 10 5 In service Maintenance 10 5 1 During in service maintenance the range finger is checked for serviceable condition in accordance with Steps 1 through 10 of Table 9 1 10 5 2 The u...

Page 17: ...in a closed room Under the field conditions replace the silica gel when the weather is dry and calm Never keep the case with fresh silica gel open for more than 1 or 2 minutes To change the silica gel...

Page 18: ...as directed under 12 3 2 11 3 To correct problems by using the individual SPTA set proceed as follows see Fig 6 11 3 1 To replace the fuse link 2 in the protection device unscrew the threaded cover f...

Page 19: ...1 3 5 The individual SPTA set is stowed in packing case 4 Fig 7 The spare Rechargeable battery pencil eraser cloth and coordinate converter are stowed in the case 12 LONG TERM STORAGE To preserve the...

Page 20: ...re so as to prevent impact 15 RECHARGEABLE BATTERY HANDLING 15 1 The rechargeable battery is supplied in discharged condition 15 2 While handling the battery be certain to avoid contact with any bare...

Page 21: ...r Cycle 2 as directed in 15 3 3 then charge it up to the operating voltage as directed in 15 3 1 With the discharging time under 3 5 hours the battery is not to be used 15 3 4 The battery that has not...

Page 22: ...brought to pin 8 of connector X2 in form of a positive pulse edge Table 16 1 Address Data X2 7 X2 6 X2 5 X2 1 X2 2 X2 3 X2 4 0 0 0 0 1 0 0 1 1 0 0 1 0 1 0 ones of meters 0000 or 0101 tens of meters f...

Page 23: ...______ Long Term Storage period _____________________ Preserved by ___________________________ Accepted after Stamp here Long Term Storage by ___________________________ 19 PACKING CERTIFICATE Binocul...

Page 24: ...ervice Postage insurance or shipping costs incurred in presenting your NEWCON product for warranty service are your responsibility Please include a check or money order made out to NEWCON OPTIK for th...

Page 25: ...3 tripod Fig 1 Range finder viewed on the side of eyepiece 1 housing 2 MEASURE 1 and MEASURE L buttons 3 belt 4 panel 5 ILLUMINATION toggle switch lever 6 Binocular eyepiece 7 screw 8 indicator eyepie...

Page 26: ...knob 2 lever 3 bracket 4 retainer 5 scale 6 framed lens 7 adjustment knob 8 compass 9 nut M8 10 framed lens 11 knob 12 support 13 level 10 14 azimuth circle 15 body Fig 4 Tripod mount 1 mounting head...

Page 27: ...12 protection device 13 indicating silica gel 14 through 18 cable 19 membrane 20 21 cover 22 diaphragm 23 brush No 7 made from synthetic fibre Fig 6 Binoculars range finder unit LRB 20 000 in packing...

Reviews: