Heater Adjustment
The Heater is adjustable from a range of 150 F-195F (see illustration
page 9) Note: Temperature at dispense point will be slightly lower.
Flushing the Mixing Chambers
The Mixing Chambers should be sanitized at least once per day. To
initialize Sanitation Mode perform the following steps:
1. Push and hold any 2 dispense buttons for 3 seconds.
Whipper will run briefly to show this has been done.
2. Push and hold any selector button to flush mixing chamber.
Flush will stay active as long as button is held.
3. Flush mode will end after 3 seconds of inactivity.
Whipper will run briefly to show the mode has ended.
Cleaning and Sanitizing Instructions
Daily Cleaning
1. Rinse the Mixing Chambers
2. Empty the Drip Pan if needed and wash with mild detergent, rinse
clean with warm water
3. Check the Canister Nozzles, clean and dry thoroughly
4. Check and clean the Sheet Metal Panels in the dispense area
10