Newco GKDF-2 Installation, Operation And Service Manual Download Page 2

 

WARRANTY 

Applies to all equipment manufactured after 2/1/2017. This warranty supersedes  

all other previous warranties that are currently in manuals. 

 

Newco warrants equipment manufactured by it for 1 year parts and labor. 

Accessories and Dispensers 1 Year parts only. 

Electronic Circuit and Control Boards- 3 years parts, 1 year labor. 

Equipment manufactured by others and distributed by Newco- please see original equipment manufacturers 

warranty, Newco will follow. 

 
These warranty periods run from the date of sale Newco warrants that the equipment manufactured by it will be 
commercially  free  of  defects  in  material  and  workmanship  existing  at  the  time  of  manufacture  and  appearing 
within the applicable warranty period. This warranty does not apply to any equipment, component or part that 
was not 

manufactured by Newco or that, in Newco’s judgment, has been affected by misuse, neglect, alteration, 

improper  installation  or  operation,  relocation  or  reinstallation,  improper  maintenance  or  repair,  incorrect 
voltage  applied  to  the  unit  at  any  time,    damage  or  casualty.  This  warranty  does  not  apply  to  any  equipment 
failures  related  to  poor  water  quality,  excessive  lime  and  chlorine  and  non  periodic  cleaning  and  descaling. 
Warranty is null and void if muriatic or any other form of hydrochloric acid is used for cleaning or deliming. In 
addition, this warranty does not apply to replacement of items subject to normal use including but not limited 
to  user  replaceable  parts  such  as  faucet  seat  cups,  sight  gauge  tubes,  washers,  o-rings,  tubing,  seals  and 
gaskets.  
 
 
This warranty  is conditioned  on  the  Buyer 1) giving Newco prompt notice of any claim to be made under this 
warranty  by  telephone  at  (800)  556-3926  or  by  writing  to  3650  New  Town  Blvd,  Saint  Charles,  MO  63301;  2)  if 
requested by Newco, shipping the defective equipment prepaid to an authorized Newco service location; and 3) 
receiving prior authorization from Newco that the defective equipment is under warranty. 
 
THE  FOREGOING  WARRANTY  IS  EXCLUSIVE  AND  IS  IN  LIEU  OF  ANY  OTHER  WARRANTY,  WRITTEN  OR 
ORAL,  EXPRESS  OR  IMPLIED,  INCLUDING,  BUT  NOT  LIMITED  TO,  ANY  IMPLIED  WARRANTY  OF  EITHER 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of Newco 
are not authorized to make modifications to this warranty or to make additional warranties that are binding on 
Newco. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and 
should not be relied upon. 
 
If Newco determines in its sole discretion that the equipment does not conform to the warranty, Newco, at its 
exclusive option while the equipment is under warranty, shall either 1) provide at no charge replacement parts 
and/or  labor  (during  the  applicable  parts  and  labor  warranty  periods  specified  above)  to  repair  the  defective 
components,  provided  that  this  repair  is  done  by  a  Newco  Authorized  Service  Representative;  or  2)  shall 
replace the equipment or refund the purchase price for the equipment. 
 
THE  BUYER’S  REMEDY  AGAINST  NEWCO  FOR  THE  BREACH  OF  ANY  OBLIGATION  ARISING  OUT  OF  THE 
SALE OF THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT 
NEWCO’S SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND. 
 
In  no  event  shall  Newco  be  liable for  any  other  damage  or  loss,  including, but not limited to, lost profits, lost 
sales,  loss  of  use  of  equipment,  claims  of  Buyer’s  customers,  cost  of  capital,  cost  of  down  time,  cost  of 
substitute equipment, facilities or services, or any other special, incidental or consequential damages. 

 
 
 
 
 
 
 

Summary of Contents for GKDF-2

Page 1: ...3 Model Warmers Width Length Height Weight Watts Amps GKF 1 1 9 1 2 19 23 1 2 35 lbs 1820 15 2 GKF 2 2 9 1 2 19 25 1 2 37 lbs 1920 16 GKF 3 3 9 1 2 19 25 1 2 39 lbs 2020 16 8 GKDF 2 2 19 19 23 1 2 62...

Page 2: ...ranty by telephone at 800 556 3926 or by writing to 3650 New Town Blvd Saint Charles MO 63301 2 if requested by Newco shipping the defective equipment prepaid to an authorized Newco service location a...

Page 3: ...Serial tag is located on rear of brewer 4 Allow 10 to 15 minutes for water in tank to heat to brewing temperature Additional water may drip from brew basket due to initial expansion of water in the t...

Page 4: ...particles are cleaned from valve seat If valve seat is worn or mutilated replace solenoid valve 3 Tighten fittings or replace coil STEAMING OR SPITTING AROUND FUNNEL 1 Main thermostat 2 High altitude...

Page 5: ...alve 1 Incoming water lines water shut off valve 2 Fuse or circuit breaker Power cord and plug connections 3 Switch continuity Normally open 4 Switch continuity Normally closed 5 Wire leads to solenoi...

Page 6: ...ultaneously pulling forward to clear the inlet tube 4 Disconnect electrical terminals connected to tank element Disconnect black lead from main thermostat 5 Disconnect the inlet to coil and coil to fa...

Page 7: ...solenoid 5 Install solenoid insuring proper flow Solenoid with an arrow arrow points toward left side of brewer Solenoid with ports labeled IN and OUT IN port connected to incoming water line 6 Insta...

Page 8: ...i limit thermostat manual reset 17 100177 Elbow male 1 4F x 1 8 59 100174 Hi limit thermostat auto reset 18 705398 GK automatic tank lid ass y 1700W 120V 60 101720 Connector 3 8C x 1 8P female 18 7054...

Page 9: ...9 EXPLODED VIEW DRAWING GKF 3 SHOWN...

Page 10: ...10...

Page 11: ...11 WIRING DIAGRAMS GK Series Brewer 120 V GK Series Brewer 120 V 240 V Newco Enterprises Inc 1735 South River Rd P O Box 852 St Charles MO 63303...

Reviews: