background image

Man Pt No 701278 

050306 

N E W C O    E N T E R P R I S E S 

INSTALLATION, OPERATION, AND SERVICE MANUAL FOR 

GK SERIES BREWERS 

 

 

 

GKDF-4 

GKF-3 

 
 

Model 

Warmers 

Width 

Length 

Height 

Weight 

Watts 

Amps 

GKF-1 

9-1/2" 

19" 

23-1/2" 

35 lbs. 

1820 

15.2 

GKF-2 

9-1/2" 

19" 

25-1/2" 

37 lbs. 

1920 

16 

GKF-3 

9-1/2" 

19" 

25-1/2" 

39 lbs. 

2020 

16.8 

GKDF-2 

19" 

19" 

23-1/2" 

62 lbs. 

5240 

21.8 

GKDF-4 

19" 

19" 

25-1/2" 

64 lbs. 

5440 

22.7 

GKDF-6 

19" 

19" 

25-1/2" 

66 lbs. 

5640 

23.5 

 

NOTE: Pour over models also available.

 

 
 
 

 
 
 
 
 
 

Summary of Contents for GKDF-2

Page 1: ...3 Model Warmers Width Length Height Weight Watts Amps GKF 1 1 9 1 2 19 23 1 2 35 lbs 1820 15 2 GKF 2 2 9 1 2 19 25 1 2 37 lbs 1920 16 GKF 3 3 9 1 2 19 25 1 2 39 lbs 2020 16 8 GKDF 2 2 19 19 23 1 2 62...

Page 2: ...ranty by telephone at 800 556 3926 or by writing to 3650 New Town Blvd Saint Charles MO 63301 2 if requested by Newco shipping the defective equipment prepaid to an authorized Newco service location a...

Page 3: ...Serial tag is located on rear of brewer 4 Allow 10 to 15 minutes for water in tank to heat to brewing temperature Additional water may drip from brew basket due to initial expansion of water in the t...

Page 4: ...particles are cleaned from valve seat If valve seat is worn or mutilated replace solenoid valve 3 Tighten fittings or replace coil STEAMING OR SPITTING AROUND FUNNEL 1 Main thermostat 2 High altitude...

Page 5: ...alve 1 Incoming water lines water shut off valve 2 Fuse or circuit breaker Power cord and plug connections 3 Switch continuity Normally open 4 Switch continuity Normally closed 5 Wire leads to solenoi...

Page 6: ...ultaneously pulling forward to clear the inlet tube 4 Disconnect electrical terminals connected to tank element Disconnect black lead from main thermostat 5 Disconnect the inlet to coil and coil to fa...

Page 7: ...solenoid 5 Install solenoid insuring proper flow Solenoid with an arrow arrow points toward left side of brewer Solenoid with ports labeled IN and OUT IN port connected to incoming water line 6 Insta...

Page 8: ...i limit thermostat manual reset 17 100177 Elbow male 1 4F x 1 8 59 100174 Hi limit thermostat auto reset 18 705398 GK automatic tank lid ass y 1700W 120V 60 101720 Connector 3 8C x 1 8P female 18 7054...

Page 9: ...9 EXPLODED VIEW DRAWING GKF 3 SHOWN...

Page 10: ...10...

Page 11: ...11 WIRING DIAGRAMS GK Series Brewer 120 V GK Series Brewer 120 V 240 V Newco Enterprises Inc 1735 South River Rd P O Box 852 St Charles MO 63303...

Reviews: