background image

                                                                                   Part No. 803172 Issued 3-29-13 Rev 012015 

 

 

 

 

MODEL 872DS   MODEL 873DS 
MODEL 872NS   MODEL 873NS 

                                          POST-MIX BEVERAGE DISPENSER 

      FOR USE WITH BAG-IN-BOX 

 

 
 

The Post-Mix Beverage Series utilizes a venturi valve to mix the syrup with the water. 

 

 

 
 

 

 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 

 

 

 

 

 

 
 
 

 

 

 
 

 

 

3650 New Town Blvd. 
St. Charles MO, 63301 
www.newcocoffee.com 
636.925.1202 
800.325.7867 
 
 

 

 

MODEL  # 

WIDTH 

DEPTH 

HEIGHT 

872DS 

9.8 

12.8 

17.1 

873DS 

12.8 

9.8 

17.1 

872NS 

9.8 

12.8 

25.6 

873NS 

18 

9.8 

25.6 

MODEL 873N 

MODEL 872DS 

MODEL 873DS 

Summary of Contents for 872DS

Page 1: ...OR USE WITH BAG IN BOX The Post Mix Beverage Series utilizes a venturi valve to mix the syrup with the water 3650 New Town Blvd St Charles MO 63301 www newcocoffee com 636 925 1202 800 325 7867 MODEL...

Page 2: ...fitting on rear of the dispenser Fitting may vary 4 Turn on the water source to the dispenser 5 Turn the yellow knob to the ON position to allow water to flow through the urn Product Loading 1 Open th...

Page 3: ...it or when changing product Flush should be performed at least once a week Note Cleaning requires the use of a cleaning flush adapter An adapter may be purchased from Newco Enterprises Inc 320282 for...

Page 4: ...sanitizer manufactures instructions Use 100 F water 7 Place BIB connector into the sanitizing solution Ensure connector is submerged to bottom 8 Place a large vessel under the faucet Lock or hold fauc...

Page 5: ...t forget to clean sanitize faucet seat cup 7 Do follow all cleaning and sanitizing pro cedures remove and store concentrate if urn will not be used for an extended period of time ie more than two days...

Page 6: ...product 1 Concentrate BIB empty 2 Product hose clogged 3 Product hose kinked 4 Check valve not seating 5 Adjustment screw in too far 1 Load new BIB 2 Clean product hose or replace 3 Check for kinks 4...

Page 7: ...e Calibration For Post Mix Beverage Dispenser Remove Top Cover Remove Product And Hang Over Sides Of Dispenser Loosen Screw Slide Access Panel Toward Front And Remove After Access Panel Is Removed Adj...

Page 8: ...xture Make small adjustments approximately 1 points or 1 8 turn at a time Replace Access Panel and Tighten Screw Replace Product Syrup Lines Top Cover To Adjust Flow Rate Rotate Adjustment Screw Clock...

Page 9: ...Part No 803172 Issued 3 29 13 Rev 012015 9...

Page 10: ...Part No 803172 Issued 3 29 13 Rev 012015 10...

Page 11: ...al plate after the dial knob is removed This area is now open for cleaning and troubleshooting When reassembling dial knob to shaft be sure that the white indicator is in the same position as before I...

Reviews: