5
110772-01 - 5/20
CL
Installation & Service Manual
Table 1-2: Dimensional Data
Table 1-2: Rating Data
Boiler
Boiler
Model
Model
Burner Capacity
Burner Capacity
Heating
Heating
Capacity
Capacity
(2)
(2)
NET AHRI Ratings
NET AHRI Ratings
(3)
(3)
AFUE
AFUE
%
%
GPH
GPH
MBH
MBH
(1)
(1)
MBH
MBH
MBH
MBH
Sq. Ft.
Sq. Ft.
CL-3-105SE
CL-3-105SE
0.75
0.75
105
105
91
91
68
68
284
284
85.7
85.7
CL3-410SE
CL3-410SE
1.00
1.00
140
140
121
121
91
91
378
378
85.0
85.0
CL4-168SE
CL4-168SE
1.20
1.20
168
168
147
147
110
110
459
459
86.4
86.4
CL4-210SE
CL4-210SE
1.50
1.50
210
210
181
181
136
136
566
566
85.1
85.1
CL5-245SE
CL5-245SE
1.75
1.75
245
245
212
212
159
159
663
663
85.6
85.6
CL5-266SE
CL5-266SE
1.90
1.90
266
266
230
230
173
173
719
719
85.3
85.3
(1)
(1)
MBH refers to thousands of BTU per hour.
MBH refers to thousands of BTU per hour.
(2)
(2)
Based on standard test procedure prescribed by the United States Department of
Based on standard test procedure prescribed by the United States Department of
Energy at combustion conditions of 13.0% CO
Energy at combustion conditions of 13.0% CO
22
..
(3)
(3)
Net AHRI Ratings are based on piping and pickup allowance of 1.333 for steam.
Net AHRI Ratings are based on piping and pickup allowance of 1.333 for steam.
The CL Series boiler is a cast iron oil-fired low
pressure steam boiler designed for use in closed
heating steam systems. This boiler must be vented
by natural draft into a fireclay tile-lined masonry
chimney or chimney constructed from type L vent or
a factory built chimney that complies with the type HT
requirements of UL103. An adequate supply of air for
combustion, ventilation and dilution of flue gases must
be available in the boiler room.
The CL Series steam boiler uses a L404F
Pressure Limit and Low Water Cut-off. This boiler
has indirect domestic water heater connections
to generate domestic hot water. Optionally, this
boiler may include a L4006 Temperature Limit and
a tankless heater to generate domestic hot water.
1
Product Description, Specification and Dimensional Data
Boiler
Boiler
Model
Model
Dimensions
Dimensions
Approv. Water
Approv. Water
Content Gallons
Content Gallons
Heat Transfer
Heat Transfer
Surface Area
Surface Area
Sq. Ft.
Sq. Ft.
Recommended Minimum Chimney
Recommended Minimum Chimney
"A"
"A"
"B"
"B"
"C"
"C"
Round in Dia.
Round in Dia.
Rectangle
Rectangle
in. x in.
in. x in.
CL3
CL3
17-3/8"
17-3/8"
8-1/4"
8-1/4"
5-7/8"
5-7/8"
16
16
14.33
14.33
66
8 X 8
8 X 8
CL4
CL4
22-3/8"
22-3/8"
10-7/8"
10-7/8"
6-7/8"
6-7/8"
20
20
20.90
20.90
77
CL5
CL5
27-3/8"
27-3/8"
13-3/8"
13-3/8"
7-7/8"
7-7/8"
24
24
27.46
27.46
88
Maximum working water pressure: 15 PSI shipped standard from factory.
Maximum working water pressure: 15 PSI shipped standard from factory.