RAD-TV USER MANUAL
New World Technologies
Page • 21
V2014.07.15
Figure 6.1.2-1: Units Dropdown Menu
6.1.3 Target Tolerance
In the Tolerance % box, enter the tolerance from the target desired to indicate a pass or a
fail.
Note:
Operation Mode
–
“
Target Pass/Fail Enable
” must be s
elected for the tolerance parameter to
be effective. Refer to Section 6.2
–
Operating Modes for more information on this option.
6.1.4 Tool Uptime
This is the amount of time (in minutes) before the tool goes to sleep. By default this time is
set to 10 minutes.
6.1.5 Bluetooth Uptime
This is the amount of time (in minutes) before the Bluetooth turns off. By default this time is
set to 9 minutes.
6.1.6 Set Points
In the Set Points box (Figure 6.1.6-1), enter the desired target that will be selectable by the
user. To select a Target, click on the desired Target. To add a new Target, press the “
Star
”
in the bottom left corner (Figure 6.1.6-1). To change a current Target, double click the Target
that needs to be changed and enter the new Target
.
Note:
The currently selected Target will have an arrow beside it (Figure 6.1.6-1).
Note:
Operation Mode
–
“
Target Pass/Fail Enable
” must be selected for the
Target parameter to be
effective. Refer to Section 6.2
–
Operating Modes for more information on this option.
Figure 6.1.6-1: Set Points Box
6.2 Operating Modes
Note
: The RAD-TV must be connected to the Data Logger for these operations to be enabled. Refer to
Section 5.2
–
Connecting the RAD-TV to a PC, for more information on how to connect the tool.
Under the
“
Tool
”
drop
down menu located in the “
RT Data Logger Software
” select
“
Setup
”, t
hen select the desired Operating Modes (Figure 6.2-1).