New Star NS-431D User Manual Download Page 11

 

 

19 

 

Cascade Configuration

 

 

Connection 

Before connecting a device (a computer or a Slave) to the Master 
under power, you must turn off the device. The Master must have 
equal or more '

PC x

' ports than that of the Slave, i.e., if NS831D is 

the master, NS831D and NS431D can be Slaves, but NS1631D can 
not. 

 

The ports labeled "

PC 1

"~”

PC 8

” can be connected to either a 

computer or a 

Slave

's 

CONSOLE

 port, as shown in figure 10. The 

ports “

PC A

"~”

PC H

” can only be connected to a computer. A power 

adapter with DC 9V/500mA output rating must be connected to the 

Master

Figure 10: Slave console connection

 

 
The maximum number of computers controlled by a master/slave 
configuration with all NS431D is 16 with 4 

Slaves

 and each 

Slave

 

connects to 4 computers, see figure 11. For an all NS831D 
configuration, the number is 64 with 8 

Slaves

 and each 

Slave

 

connects to 8 computers, see figure 12. For an all NS1631D 
configuration, the number is 136, see figure 13. The 

Master

 

NS1631D connects to 8 Slaves and 8 computers, and each 

Slave

 

connects to 16 computers. 

 

 

20

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 11: Cascaded 4-port NewStar KVM Switchs 

 
 
 

 

 
 

Figure 12: Cascaded 8-port NewStar KVM Switchs

 

 

 

Summary of Contents for NS-431D

Page 1: ...Optional Rack Mount Accessories 9 Operation Front Panel Push Buttons 10 OSD On Screen Display Operation 11 Hot key Commands 17 Cascade Configuration Connection 19 Change Configuration while Running 2...

Page 2: ...ters supplied with each NewStar KVM Switch Switch and control the computers from one PS 2 mouse The NewStar KVM Switch automatically identifies the mouse and switches to proper mouse protocol 2 High V...

Page 3: ...nfiguration Connect a PS 2 keyboard a PS 2 mouse and a VGA multi sync monitor directly to the Master s CONSOLE port Then connect multiple sets of keyboard mouse and monitor cables to the PC x ports of...

Page 4: ...o the HD DB 15 VGA port of a Master CONSOLE must be capable of synchronizing with the computer s video signal If you are uncertain about the monitor type please consult the monitor user s manual Conne...

Page 5: ...on You must power up the Master NewStar KVM Switch before turning on any other devices For single KVM Switch 1 Apply a power adapter to the Master 2 Turn on computers For cascade 1 Apply a power adapt...

Page 6: ...pport The front panel indicator changes to reflect the computer port selected red and whether the port is connected to a powered computer green The indicator flashes red when it is in either Auto Scan...

Page 7: ...operating status For a 4 port KVM switch you can only use the and arrow keys to highlight a computer A triangle mark to the right of a name indicates the port is cascaded to a Slave the number at the...

Page 8: ...f them are marked with a triangle indicating there are options to choose from Using the UP and DOWN arrow keys select the functions and press ENTER Available options will be 14 shown in the middle of...

Page 9: ...key Menu When you hit the left CTRL key twice within two seconds the Hotkey Menu appears displaying a list of hot key commands if the option is On The Hotkey Menu can be turned Off if you prefer not t...

Page 10: ...uters one by one at a fixed interval left Ctrl left Ctrl F 1 18 When Auto Scan detects any keyboard or mouse activity it suspends the scanning till activity stops it then resumes with the next compute...

Page 11: ...uter A power adapter with DC 9V 500mA output rating must be connected to the Master Figure 10 Slave console connection The maximum number of computers controlled by a master slave configuration with a...

Page 12: ...re it is connected to the Master 22 Appendices Specifications Specifications NS431D NS831D NS1631D User port number 1 1 1 Computer port number 4 8 16 Cascade control PC number Up to 16 Up to 64 Up to...

Page 13: ...ly one PC is turned on Scan mode works for power on computers only Scan type is eye mark selected but no power up PC is eye mark selected Turn on computers Set proper Scan Type in OSD and determine wh...

Page 14: ...r representation expressed or implied with respect to the contents or use of this documentation and especially disclaims its quality performance merchantability or fitness for any particular purpose T...

Reviews: