48
14.
Move Anderson valve back to original position.
De-Winterize
1.
Make sure the storage tank drain valve is closed.
2.
Put water in the storage tank and pump at least one gallon through the
water pump in order to remove the antifreeze from the water pump.
3.
Keep the water heater by-pass valves open. They should be in the by-pass position.
4.
Turn off the water pump.
5.
Drain water from freshwater tank.
6.
Using the external water supply open the kitchen faucet, bath faucet, inside
and outside shower, turning on both the hot and the cold, and flushing the stool
until the antifreeze solution is flushed out of the system and the water flows
clear. Once the system has been flushed, open the water heater by- pass valves.
7.
This would be a good time to sanitize the freshwater system. (see sanitizing section)
Long Term Storage/Winterizing
All routine maintenance is the responsibility of the owner and is not covered
by the New Horizon’s Limited Warranty. Use the enclosed maintenance
record to log all performed maintenance as required. Please note that
damage caused by improper or unapplied maintenance is not covered by
warranty.
To store your unit for the winter months, it is necessary to winterize the water
system to help prevent freezing. To do this, follow these instructions:
1.
The water heater must remain off during this process. Shut off the water pump and
make sure the water supply valves are closed.
2.
To drain the freshwater tank, open the drain valve.
3.
Open the low point drain valves. These are in the basement area. There is one drain
valve for each water line, one cold and one hot. The is done to drain most of the
water out of the system.
4.
After the water heater has cooled off, remove the drain plug to drain the water from
the water heater. In the interior compartment beside the water heater, there are two
by-pass valves. The shut off valves must be closed, and the by-pass valves must be
open prior to winterizing to prevent the anti-freeze solution from entering the water
heater. When the valves are in the horizontal position, it is in the by-pass mode.
When they are vertical, the water heater is in use.
5.
Close the low point drains to prevent the anti-freeze from draining through the lines
onto the ground.
6.
Remove the water filter. See instructions for winterizing water filters.
7.
Close the water supply valve that flows from the pump to the tank.
Summary of Contents for MAJESTIC
Page 1: ...O WN E R S MA N U A L ...
Page 12: ...S E C T I O N O N E ...
Page 19: ...S E C T I O N T WO ...
Page 23: ...10 ...
Page 30: ...S E C T I O N T H R E E ...
Page 39: ...S E C T I O N F O U R ...
Page 47: ...S E C T I O N F I V E ...
Page 60: ...S E C T I O N S I X ...
Page 69: ...S E C T I O N S E V E N ...
Page 75: ...S E C T I O N E I G H T ...
Page 78: ...S E C T I O N N I N E ...
Page 86: ...S E C T I O N T E N ...
Page 90: ...68 ...
Page 91: ...69 ...
Page 92: ...70 RV ARRIVAL SETUP ...
Page 93: ...71 ...
Page 94: ...S E C T I O N E L E V E N ...
Page 97: ...H E L P F U L T O O L S ...
Page 101: ...75 MAINTENANCE RECORD Date MILEAGE DESCRIPTION PERFORMED BY ...
Page 102: ...76 ...
Page 103: ...77 ...
Page 104: ......