HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM
BAIL10CVT063FAB
18
Front hydraulic power lift
CLOSED CENTRE LOAD SENSING HIGH PRESSURE HYDRAULIC CIRCUIT
The principal of operation of the closed centre load sensing high pressure hydraulic circuit with variable flow piston
pump is to supply oil flow on demand. It also enables simultaneous operation of the trailer brakes, hydraulic lift,
remote control valve assemblies and front axle suspension where fitted. The load sensing variable flow piston pump
offers significant benefits in reducing the engine power loss that occurs in open centre systems where a high volume
of oil, often far in excess of demand, is continuously pumped round the hydraulic circuit even when they are not being
operated.
A fixed displacement pump (Charge Pump) serves as an initial displacement pump for the variable displacement pump
. The variable displacement pump first of all supplies oil to the trailer brake valve (where fitted), the remote valves
and electronic draft control valve and a pilot oil supply with lower priority. The highest load pressure is indicated to
the flow and compensating valve on the pump via the load sensing line. The flow and compensator valve controls
the pump pressure in such a way that it always exceeds the highest load pressure by a pre-set difference. A priority
valve for low pressure circuit demand is located in the bottom subplate of the remote valve stack. Tractors fitted with
Electro-hydraulic remote valves also have high pressure oil supplied from the variable displacement pump to the top
plate of the remote valve stack. The oil passes through the top plate via a small filter and a pressure limiting valve (
20 - 22 Bar
). The oil is then directed to the pilot oil supply of the electro-hydraulic control valve.
The main filter
(1)
and the charge filter
(2)
Figure
19
are installed on tractors with variable displacement pump (CCLS
system).
1.
Main Intake (Suction) filter
2.
Charge filter
3.
Hydrostat filter
84479148A 15/09/2011
A.10.A / 24
Summary of Contents for T7.170
Page 4: ...84479148A 15 09 2011 Find manuals at https best manuals com ...
Page 5: ...INTRODUCTION 84479148A 15 09 2011 1 Find manuals at https best manuals com ...
Page 19: ...INTRODUCTION ZEIL06CS0136F0A 2 ZEIL06CS0135F0A 3 84479148A 15 09 2011 15 ...
Page 25: ...INTRODUCTION Regarding filling quantity see Capacities 84479148A 15 09 2011 21 ...
Page 81: ...This as a preview PDF file from best manuals com Download full PDF manual at best manuals com ...