6
Noise level dB(A)
20
~
45
20
~
46
21
~
46
The technical specification of our heat pumps is provided for information purpose only. We reserve
the right to make change without notice in advance.
1. Ambient temperature
2. Initial water temperature
3. Noise at 1m, 4m and 10m comply with Directives EN ISO 3741 and EN ISO 354
4. Calculate according to an in-ground private swimming pool covered with bubble
Model
NERS-G110Y-B1
NERS-G150Y-B1
NERS-G180Y-B1
Air temperature: 26ºC, inlet / outlet water temperature: 26ºC/28ºC ,Humidity 80%
Heating capacity
(
kW
)
2.8
~
11.5
3.5
~
15.3
4.35
~
18
Power input
(
kW
)
0.193
~
1.79
0.243
~
2.41
0.306
~
2.83
COP
6.4
~
14.5
6.35
~
14.4
6.36
~
14.2
Boost mode
Heating capacity
(
kW
)
11.5
15.3
18.0
COP
6.4
6.35
6.36
Smart mode
Heating capacity
(
kW
)
9.1
11.55
14.01
COP
7.82
7.68
7.5
Silent mode
Heating capacity
(
kW
)
5.5
7.35
8.7
COP
11.2
10.62
10
Air temperature: 15ºC, inlet / outlet water temperature: 26ºC/28ºC,Humidity 70%
Heating capacity
(
kW
)
2.21
~
8.23
2.95
~
11.15
3.42
~
13.33
Power input
(
kW
)
0.283
~
1.614
0.386
~
2.226
0.453
~
2.693
COP
5.1
~
7.81
5.01
~
7.64
4.95
~
7.55
Boost mode
Heating capacity
(
kW
)
8.23
10.86
13.33
COP
5.1
5.01
4.95
Smart mode
Heating capacity
(
kW
)
6.58
8.65
10.55
COP
5.73
5.72
5.68
Silent mode
Heating capacity
(
kW
)
4.37
5.55
6.72
COP
6.57
6.55
6.51