Page 7
A. Vertical exit using (6" Single wall minimum 24 ga. blued or black
pipe and any listed 2100° UL 103 HT. TYPE Chimney)
Without optional close clearance shield and pipe shield
Model FS 21 minimum clearance to combustibles
NOTE:
All clearances are to combustibles without close clearance shields and pipe shield, using 6"
Single Wall minimum 24 ga. blued or black pipe and minimum floor protector
.
The clearances
above may be reduced. Follow
NFPA-211
codes if available or follow instructions on (Pages 10,
and 11).
C
C
C
C
Figure 3.
SINGLE WALL
CONNECTOR PIPE
CEILING SUPPORT
CEILING
INSTALLATION
FLASHING
CONTEMPORARY CAP
STORM COLLAR
DO NOT OBSTRUCT
CAULK
NEW BUCK
SIDE
WALL
BUCK STOVE
LISTED 2100° UL 103 HT
TYP. CHIMNEY
RADIATION SHIELD
LISTED 2100° UL 103 HT TYP.
Figure 2.
BACK WALL
A
E
B
F
D
G
A
E
B
D
F
BACK WALL
SIDE WALL
PROTE
C
TO
R P
A
D
G
A B C D E F G
MODEL 21 25”
13" 13"
15.5" 8" 6"
16"
Summary of Contents for FS 21
Page 2: ......