Page 33
NOTE: You may want to have your chimney cleaned by a professional before installing unit.
SERVICING
Repair and replacement work should only be done by a qualified service person.
Always shut off the gas supply and make sure that heater is cool before beginning any service
operation. Always check for gas leaks after servicing.
REPLACEMENT PARTS
A parts list with exploded view follows. Always include correct name, part number, and model
number of the heater when ordering service parts.
KEY#
PART DESCRIPTION
PART NUMBER
SIT - MILLIVOLT
1.
O.D.S. PILOT (L.P.) O.P. ASSEMBLY
PE 8404C
1.
O.D.S. PILOT (NAT) O.P. ASSEMBLY
PE 8204C
2.
GENERATOR ASSEMBLY (Part of Pilot Assembly)
3.
PILOT TUBE 3/16"
MF 31612 ALMTUB
4.
GENERATOR WIRE
(Part of Pilot Assembly)
5.
REAR BURNER
PO VE1002
FRONT BURNER PO VE1001
6.
INLET ELBOW PH 4966
7.
3/8" COMP. NUT & SLEEVE
PH 616 & PH 606
8.
3/8" BURNER SUPPLY TUBE (FLEX)
- 2 pieces 12"
PO T6-12
9.
24" SWITCH WIRES
PE 30JUMPER
10.
CARLING SWITCH
(AUTO/OFF/MANUAL)
PE RC211RB
11.
PIEZO STRIKER
PE 124461
12.
PIEZO 18" IGNITOR WIRE
PE 8400-014
13.
MALE RUN TEE FITTING
PH 64A-66
14.
THERMO-COUPLE
15.
MANIFOLD OUTLET CONNECTOR
PH 68A-6C
16.
ORIFICES
L.P.
REAR
#1.35mm
PO 135 MVORF
FRONT
#54
PO 54 MVORF
NATURAL
REAR
#43
PO 43 MVORF
FRONT
#46
PO 46 MVORF
17.
820 mv. S.I.T. VALVE
LP - PE 820-636
NAT - PE 820-637
18. 8”L 3/8”BURNER SUPPLY LINE MF382ALMTUB
(3/4”
-
3/8” FLARE/3/8” COMP. N&S FITTINGS)
OPTIONAL
CANOPY (HOOD)
MAPSFPC002
*
OAK
LOG SET 24” EMBER VISION CERAMIC
*
PINE
LOG SET 24” EMBER VISION FIBER
*
OAK
LOG SET 30” EMBER VISION CERAMIC