This instruction manual will help you obtain a safe, efficient, dependable installation for your appliance 
and vent system.  Please read and understand these instructions before beginning your installation. 
 
The model DV23ZC is a sealed combustion, air circulating gas appliance designed for residential and 
mobile home applications.  The appliance must be installed with Dura-Vent GS vent system that is 
routed to outside atmosphere.  It is also listed for bedroom installations. 
 
This appliance is designed to operate on natural or propane gas.   A millivolt gas control valve with piezo 
ignition system provides safe, efficient operation.  No external electrical power is required to operate the 
gas valve and burner.  120VAC is required to operate the room air fan. 
 
This appliance complies with National Safety Standards and is tested and listed by (ITS) Intertek Testing 
Services (Warnock Hersey)  to 

ANSI Z21.88-2002 and CSA 2.33-2002 

ISA  CAN/CGA-2.17-M91-

Appliance for use at high altitudes.  Installation must conform to local codes.  In the absence of local 
codes, installation must comply with the current 

National Fuel Gas Code, ANSI Z223.1/NFPA54

.

.  

(In Canada, installation must comply with the current 

CAN-1B149 

installation code.) 

 

Approved for manufactured (Mobile) home installation.

  For mobile housing, Title 24 CFR, Part 

3280 or when such a standard is not applicable, the standard for manufactured home installation, ANSI /
NCBS A225.1 or standard for gas  equipped recreation vehicles and mobile housing, CSA Z240.4. 

DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE 
APPLIANCE OR ITS COMPONENTS.  ANY MODIFICATION OR ALTERATION 
MAY VOID THE WARRANTY, CERTIFICATION AND LISTINGS OF THIS UNIT. 
 

SPECIFICATIONS - MODEL DV23ZC 
 
GAS:   

 

 

    NAT. 

 

 

 

     L.P.  

 HIGH 

FIRE 

 

  

22,000 

BTU 

   22,000 

BTU 

 LOW 

FIRE 

 

  

14,000 

BTU 

   17,600 

BTU 

 
GAS INLET PRESSURE: 

    NAT. 

 

 

 

     L.P. 

 

MAX. INPUT  

10.5" W.C. 

 

 

 

   14.0" W.C. 

 

MIN.  INPUT  

*5.0" W.C. 

 

 

 

   10.5" W.C.    

 *5.0" W.C. is minimum inlet gas supply pressure for the purpose of input adjustment. 
 
MANIFOLD PRESSURE:       NAT.  

 

 

 

     L.P. 

    3.5" 

W.C. 

   10.0" 

W.C. 

 
STEADY 

STATE 

EFFICIENCY: 

    

    NATURAL 

GAS 

77.10%    

    L.P. 

GAS 

 77.10% 

 

 

 

FLUE VENT   

 

4" INNER,  6" OUTER; DURA-VENT MODEL GS 

 
SAFETY 

 

 

AGA CERTIFIED PILOT GENERATOR, MILLIVOLT  

    SYSTEM 

ACTIVATED 

WITH SWITCH OR THERMOSTAT. 

 

Summary of Contents for DV23ZC

Page 1: ...TY OF THIS OR ANY OTHER APPLIANCE WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas suppl...

Page 2: ......

Page 3: ...nt Length Requirement 10 Vent Assembly 11 Horizontal Termination 11 Vertical Termination 14 High Altitude 17 Gas Valve Connection 18 Gas Pressure Checks 18 Operating Instructions 19 Lighting Instructi...

Page 4: ...2...

Page 5: ...llation must conform to local codes In the absence of local codes installation must comply with the current National Fuel Gas Code ANSI Z223 1 NFPA54 In Canada installation must comply with the curren...

Page 6: ...room as the appliance Clothing or other flammable material should not be placed on or near the appliance Any safety screen or guard removed for servicing this appliance must be replaced prior to opera...

Page 7: ...conventional construction materials However if installed on combustible materials such as carpeting vinyl tile etc a metal or wood barrier covering the entire bottom surface must be used Right and lef...

Page 8: ...INSTALLATION Figure 1 6...

Page 9: ...2 RISE NOTE INTERIOR HORIZONTAL MINIMUM INSTALLATION NOTE Figure 2 NOTE You may replace or cover this piece of material with a more decorative non combustible material when the unit is installed SUPPL...

Page 10: ...emperature silicone sealant Apply a bead of sealant around the bell section of the inner pipe prior to joining the pieces together The outer pipe joint may be sealed with metal foil tape or with silic...

Page 11: ...cm G Clearance to inside corner 12 inches 30 cm H Not to be installed above a meter regulator assembly within 3 feet 90 cm horizontally from the centerline of the regulator I Clearance to service reg...

Page 12: ...iance may operate in some installations that fall outside this vent requirement chart we cannot ensure its performance Figure 3 18 12 0 6 MINIMUM MAXIMUM VENT REQUIREMENTS MINIMUM DISTANCE FROM BEND O...

Page 13: ...and fittings are designed with special twist lock connections Assemble the desired combination of pipe and elbows to the appliance adapter with pipe seams oriented towards the wall or floor as much ou...

Page 14: ...are hole in the exterior wall where the vent will be terminated If the wall being penetrated is constructed of non combustible material e g masonry block or concrete a 9 diameter hole is acceptable 5...

Page 15: ...ermination slide the black decorative wall thimble cover over the vent pipe 7 Slide the appliance and vent assembly toward the wall carefully inserting the vent pipe into the vent cap assembly It is i...

Page 16: ...the appliance adapter up through the Round Support Box Ensure that all pipe and elbow connections are in their fully twist locked position See Figure 10 4 Cut a hole in the roof centered on the small...

Page 17: ...rements described in Figure 13 Note that for steep roof pitches the vent height must be increased High wind conditions nearby trees adjoining roof lines steep pitched roofs and other factors can resul...

Page 18: ...14 The opening should be framed to 10 x 10 inside dimensions in the same manner as shown in Figure 11 Figure 14 Any occupied areas above the first floor including closets and storage spaces which the...

Page 19: ...e elevation that the appliance is installed at by referencing the chart shown below Be sure to check both front and rear orifice for proper drill size DRILL SIZING CHART RECOMMENDED SIZE vs ALTITUDE A...

Page 20: ...When checking pressures follow these steps Check and adjust if required the inlet pressure first and then check and adjust if required the manifold pressure 1 With gas valve knob in OFF position use...

Page 21: ...ance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle to the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any el...

Page 22: ...hooking up the gas supply If so the control knob may need to be pressed in for thirty 30 seconds This will allow air to bleed from the gas system 7 With control knob pressed in push down and release i...

Page 23: ...d SHUTTING OFF BURNER ONLY Pilot stays lit 1 Turn control knob clockwise to the PILOT position CAUTION HOT while in operation Do Not Touch Keep children clothing furniture gasoline and other liquids h...

Page 24: ...with the branch end resting in the notch of the rear log toward the rear of the unit 6 5 Place the left top log 5 in the notch on the top left of rear log and the other end in the notch on top left of...

Page 25: ...er the studs on the stove three at the top and three at the bottom Simply tighten nut on each Do not abuse door i e drop or slam it When the glass door has been removed for cleaning or service careful...

Page 26: ...G ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING THE APPLIANCE WHEN INSTALLED MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR IN THE ABSENCE...

Page 27: ...olt system which enables you to choose from many of the convenient options available 1 Remote control with built in room thermometer 2 Wall Switch 3 Wall Thermostat OUT L TO IP IN OUT L TO IP IN VALVE...

Page 28: ...are free from lint and other obstructions Never block or obstruct grill openings Check condition of door gasket Gaskets must be tight Replace if necessary Be sure the vent termination is open and fre...

Page 29: ...199615 1 S I T PILOT NAT ASSEMBLY PE 199616 2 GENERATOR PE 240002 3 1 8 PILOT TUBE MF 1812 ALMTUB 4 GENERATOR WIRE 5 18 H BURNER POH BURN001 6 ORIFICES NAT SIZE L P SIZE REAR 44 REAR 1 25mm PO 50 125...

Page 30: ...REPLACEMENT PARTS Figure 22 16 28...

Page 31: ...STAT WIRES PE 30JUMPER FRONT LOUVER ASSEMBLY TOP BOTTOM PO DV23FG DOOR GLASS PG DV2341 DOOR GLASS GASKET TAD POLE W ADHESIVE RP GT716B11 5 PIECE LOG SET PO23DVLOG REAR LOG 1 MIDDLE LOG 2 FRONT LOG 3 R...

Page 32: ...e stove including those removable with common hand tools The cost of parts only are included The customer pays any labor or transportation charges required Electrical motors wiring switches gas compon...

Page 33: ...nyone other than an author ized service representative are not covered under this warranty In addition these unauthorized repairs may result in additional malfunctions the correction of which is not c...

Reviews: