New Age BIOSONYC User Manual Download Page 11

Rev. 02 of 10/12/04 

11/24 

 

Kind of Program 

No. 

Name of the program 

Articulation 

pathologies 

Arthritis-Arthrosis 

Articulation stiffness 

Sprains 

Lumbago 

Muscle pathologies

 

Myalgia 

10 

Pangs 

11 

Strains 

12 

Contractures 

13 

Bruises 

Tendon pathologies 

14 

Tenosynovitis 

15 

Tenovaginitis 

16 

Epicondylitis 

17 

Periarthritis 

18 

Bursitis 

 

3 MHz Therapy Programs (new*) 

 

Programme Type 

Name on display 

Timer 

Power 

Freq. Mod. 

Superficial 

pathologies

 

Sprains 

10 

1,5 W 

Continue 

Strains 

10 

1,5 W 

Continue 

Contractures 

1 W 

Continue 

Oedemas 

10 

1 W 

Continue 

Tenonitis 

10 

1 W 

1/2 

Epicondylitis 

10 

1 W 

1/2 

Cicatrization 

10 

1 W 

Continue 

 

NOTE (*):

 some 1 MHz therapy programs are available also with 3 MHz  frequency for 

superficial pathologies (see table) except 

Cicatrization

 program, wich is completely new 

and specific for skin scars, cuts, wounds, etc. For the use see 1 MHz Programs. 

 

5.1.2

 

– Descriptio n of  t herapy prog ra ms

 

 

The following tables describe the various preset programs, subdividing them according to 
the  anatomic  parts  involved  in  the  pathologies  they  were  designed  for.  On  each  of  the 
following  tables,  the  first  column  shows  the  program  on  the  display  –  so  it  can  be 
identified  immediately  –  together  with  its  duration,  while  the  second  column  contains 
explanations regarding the program and its applications. 

 

 

NOTE:

  during  the  program  it  is  possible  to  increase  or  decrease  the  Timer  by  pressing 

UP/DOWN keys.

 

Summary of Contents for BIOSONYC

Page 1: ...Telefax 39 0545 369028 Website www newageitalia it e mail info newageitalia it This document is the property of New Age Italia srl All rights reserved It is forbidden to copy or reproduce it in any w...

Page 2: ...hoose the program 8 3 5 Start of therapy 8 3 6 Setting the power of emission 8 3 6 1 Contact control 8 3 7 Program interruption 8 3 8 Turn off the device 9 Chap 4 APPLICATION TECHNIQUES 9 4 1 Direct c...

Page 3: ...ogram 18 Chap 6 POWER SUPPLY 19 Chap 7 MAINTENANCE 19 7 1 Head and cables 19 7 2 Device 19 7 3 Replacing the power supply cable 19 Chap 8 SYMBOLS 20 Chap 9 WARNINGS 21 Chap 10 TECHNICAL SPECIFICATIONS...

Page 4: ...2 W h y u s e t h e B I O S O N Y C BIOSONYC houses inside itself all the technology needed to generate ultrasounds through the use of pre set programs contained in its memory The generator carries o...

Page 5: ...activity however in many cases they may also be due to aging rheumatisms muscular hypotrophy lack of balance due to little movement these cases are increasing steeply due to the progressive rising of...

Page 6: ...in the immediate neighbourhood of the eyes or the uterus abdomen lumbar area in case of pregnancy due to the risk of provoking cavitation even with a proper dosage The presence of articular prostheses...

Page 7: ...PPLY OUTPUT ON OFF DISPLAY START UP DOWN PAUSE STOP INTENSITY INTENSITY OUTPUT 3 2 C o n n e c t i n g t h e h e a d Before turning the device on connect the head to the output socket of the device vi...

Page 8: ...e break off the therapy by pressing pause stop NOTE during the program it is possible to increase or decrease the Timer by pressing UP DOWN keys one minute each touch 3 6 1 Contact control To detect t...

Page 9: ...ery limited surface holding the handpiece firmly down on the area affected by hand or by the mechanical arm not provided together with the device which allows the operator to devote himself to other p...

Page 10: ...issue being treated 1 Bone tissue programs which deliver ultrasounds with the most common parameters for the treatment of pathologies affecting the bone structure and related structures 2 Articulation...

Page 11: ...ization 10 1 W Continue NOTE some 1 MHz therapy programs are available also with 3 MHz frequency for superficial pathologies see table except Cicatrization program wich is completely new and specific...

Page 12: ...ges it stabilizes the local metabolism and favours the afflux of the blood 10 minutes Articular stiffness Treatment of stiffness affecting the articular cartilages it restores the trophism of the cart...

Page 13: ...ndirect technique by immersion DIRECT METHOD MOBILE TECHNIQUE Area to be stimulated Notes about the position of the head Muscle Move the head all over the surface of the muscle Knee ankle Move the hea...

Page 14: ...ither supine or prone depending on the area of application This position must be kept throughout the duration of the session in order to facilitate the effects produced by the vibrations especially th...

Page 15: ...ffuse compact cellulitis Lymphatic draining 7 Localized lymphatic draining 8 Diffuse lymphatic draining Thinning 9 Local thinning 10 Diffuse thinning Skin pathologies 11 Boils 12 Granulomas 13 Local d...

Page 16: ...irculation and lymphatic draining 25 minutes Diffuse compact cellulitis Treatment of diffuse cellulitis it breaks down the fat frees the fluids which are being withheld and facilitates local circulati...

Page 17: ...utei Move the head over the whole area affected by cellulitis Thighs inside outside Move the head over the side affected by cellulitis DIRECT METHOD FIXED TECHNIQUE Area to be stimulated Notes about t...

Page 18: ...ions especially the flow of blood increased due to the vascular expansions as a consequence of the heating induced in the affected area thus facilitating the draining of the freed substances fats exce...

Page 19: ...ce to constantly check the state of wear of the insulation cable before connecting it to the power mains If it has been damaged even in part replace the cable at once Immediate maintenance New Age Ita...

Page 20: ...to the company service laboratories or else delivered to the dealer it was purchased from Service Centre New Age Italia srl Via Keplero 7 48022 Lugo RA Tel 39 0545 32019 Telefax 39 0545 369028 Website...

Page 21: ...surgical device in order to prevent danger both to the patient and to the device The instrument will work according to specification if the environment is kept at a temperature between 5 and 40 C and...

Page 22: ...h mm Weight 1 Kg Class II Type BF Classification in terms of fluid entrance IP20 Safe when there are flammable anaesthetic gases present it does not belong to categories AP or APG Appliance designed t...

Page 23: ...or to replace consumed or finished material you can purchase accessories separately 1 1 1 B a s i c B I O S O N Y C e q u i p m e n t BIOSONYC comes complete with Device 1 3 MHz 45 mm head Gel for ul...

Page 24: ...der Windt A de Winter Physiotherapy for patients with soft tissue shoulder disorders a systematic review of randomised clinical trials BMJ 1997 315 25 30 5 July A Vasta Manuale pratico illustrato di...

Reviews: