–   C A U T I O N  

 

  Pay particular attention in the employment of the handle for not compromising  

the effectiveness of the treatment. 

  Use  the  device  only    with  electric  systems    conforming  to  the  Safety  Current 

Regulations 

  The  instrument  has  a  degree  of  protection  IP20  (to  see  sec.  "Technical 

characteristics")  and  it  dissuades  the  use  in  the  immediate  proximities  of  liquids, 
because not protected from their entry. 

  We  would  not  recommend    to  use  in  the  immediate  proximities  of  cellular 

telephones (keep  them at least to some meters of distance). 

    Operate  in  proximity  (for  example  1  meter)  of  an  instrument  for  short  waves 

therapy , or microwaves, can produce instability in the output of the stimulator. 

 Don't simultaneously connect the patient with the LASETRON CARD and with a 

surgical  instrument  HF,  to  avoid  dangers  for  the  patient  and  for  the  same 
instrument. 

 

  Don't use in presence of equipments for the monitoring of vital parameters 

   The tool works according to its specifications, if the environment is maintained 

to  an  inclusive  temperature  between  the  5°  and  the  40°  C  and  with  an  inferior 
humidity  to  the  80%.  The  same  conditions  have  to  be  maintained  during  the 
transport and the storage.   

    In  case  of  malfunctions  and  breakdowns,  it  is  opportune  to  send  the  tool 

exclusively to the house builder. 

 We recommends not to operate in proximity of inflammable substances 
 Don't use different accessories from those furnished in endowment. 

 

It is important to inform the patient about the type of feeling to perceive during 

the therapy, such as to  intervene immediately, interrupting the session through the 
commands of the device or removing the handle, in the case the perception is not 
the correct one anymore.  

 

If the power of emission or its regulation causes elevated heating or pain in the 

treated  zone  it  is  necessary  to  reduce  immediately    the  intensity  of  stimulation  or 
eventually to interrupt the application. 

 

 

Summary of Contents for BIOLASER

Page 1: ...545 32019 Telefax 39 0545 369028 Web www newageitalia it E mail info newageitalia it This document is the property of New Age Italia All rights are reserved This document may not be copied or reproduc...

Page 2: ...ns 5 Side Effects 5 Cap 3 Operation 6 Connection to the electric net 6 Connection of the handle 7 Application of the handle 7 Switch on of the device 7 Selection of the program 7 Intensity of emission...

Page 3: ...3 Immediate maintenance 10 Cap 7 11 Cap 8 CAUTION 11 Cap 9 TECHNICAL CHARACTERISTICS 12 Supply 12 Output characteristics 12 Other characteristics 12 Cap 10 SYMBOLS 13 Cap 11 STANDARD ENDOWMENT AND AC...

Page 4: ...rough the use of the presetted programs contained in its memory and the 20 free programs Thanks to BIOLASER therefore it is possible to apply the infrared therapy with standard programs and to have th...

Page 5: ...ects with pace maker neoplasie tumori pregnancy in progress epilepsy photosensitivity children areas of growth S i d e E f f e c t s Cutaneous burns if the intensity is notable and if are present diso...

Page 6: ...modulation 6 ON OFF 7 Cable output 8 UP DOWN program selection timer adjustment C o n n e c t i o n t o t h e e l e c t r i c n e t BIOLASER can be used with battery or fed to electric current connec...

Page 7: ...he program with the keys UP DOWN see section Programs and confirm with START The programs are listed in the charts in Preset protocols I n t e n s i t y o f e m i s s i o n The intensity of the emissi...

Page 8: ...IOLASER programs table N Prog Name on display Pathology to be treated P 1 Cervical Cervical P 2 Pubalgy Pubalgy P 3 Dorsalgia Dorsalgia Bone pain P 4 Lumbago Lumbago P 5 Epicondilitis Epicondilitis P...

Page 9: ...am Repeat the operation so that to apply the therapy on the whole interested surface 4 2 S e s s i o n s Apply the laser therapy 3 4 times a week at alternate days up to the disappearance or appreciab...

Page 10: ...example if left next to intense heat sources you doubt that some liquids can be penetrated inside the wrap or other parts of the instrument are damaged broken or lacking the functionality of the instr...

Page 11: ...nd with a surgical instrument HF to avoid dangers for the patient and for the same instrument Don t use in presence of equipments for the monitoring of vital parameters The tool works according to its...

Page 12: ...c s Dimensions 225x170x120h mm Weight 1000 g approx Class I Tipo BF Class II Tipo BF Classification in comparison to the entry of liquids IP20 Safety in presence of inflammable anaesthetic gas it is n...

Page 13: ...DEVICE IS MARKED AT THE SENSES OF THE 0476 DIRECTIVE CEE 93 42 Cap 11 STANDARD ENDOWMENT AND ACCESSORIES B a s i c e n d o w m e n t BIOLASER is complete with Device Handle at 9 diods Protective goggl...

Page 14: ...d Minerva Medica Torino 1993 B Gialanella G D alessandro R Santoro Terapia fisica pratica ED Marrapese Roma 1997 A Vasta Manuale pratico illustrato di terapia fisica ED Marrapese Roma 1998 C Cisari G...

Reviews: