88 Series Outboard / 8803 Dual EQ
Issue 2
2 - Front Panel Controls
On/Off
The Neve Logo Switch on the right hand side of the unit switches
the unit on and off.
Input Section
Input trim
Sets the level of the input signal.
The trim range is from –20dB to +20dB and can encompass signals
from sources referenced to +4dBu or to –10dBV.
Signal led
(yellow)
When lit indicates that a signal is present at the unit input. The
trigger level is –30dBu.
Clip led
(red)
When lit indicates that the signal is at 25dBu and there is danger of
clipping occurring.
The signal level is monitored at three stages:
•
Input pre-trim;
•
Input post-trim;
•
Output.
The LED is triggered by any one of these levels reaching 25dBu.
Filter Section
High Pass Filter
The high pass filter has a 12dB per octave (20dB per decade) slope
and a frequency range from 30Hz to 300Hz.
It is switched into circuit by pressing the
Hi Pass
frequency control.
The associated led will light.
Low Pass Filter
The low pass filter has a 12dB per octave (20dB per decade) slope
and a frequency range from 1.5kHz to 18kHz.
It is switched into circuit by pressing the
Lo Pass
frequency control.
The associated led will light.