     Female Chassis

Connect the XB2 female connector from the back 
into the female chassis.

Attention! Check the correct keying position.

A

A

  

I  

HANDLING INSTRUCTION

®

optical

CON

 DRAGONFLY

3

BDA 567

KEY UP

B    Chassis Connector Cleaning / Inspection

Tools: 

Ÿ 

99% isopropyl alcohol (IPA) or cleaning fluid (FOCD-CF) or distilled water

Ÿ 

Dust remover (Air in a can)

Ÿ 

STICKLERS Clean STIXX MCC-EB12 - Expanded Beam Lens

Disconnect  both  cable  ends  for  safety 
reasons.
Do not stare into beams or view directly with 
optical instruments.

Remove the protection cap:
-  The Male connector has a lockable cap.
-  The Female connector has a pluggable cap.

Check the lenses for contamination.

If there is no visible contamination

®

 No cleaning necessary.