Female Chassis
Connect the XB2 female connector from the back
into the female chassis.
Attention! Check the correct keying position.
A
A
I
HANDLING INSTRUCTION
®
optical
CON
DRAGONFLY
3
BDA 567
KEY UP
B Chassis Connector Cleaning / Inspection
Tools:
Ÿ
99% isopropyl alcohol (IPA) or cleaning fluid (FOCD-CF) or distilled water
Ÿ
Dust remover (Air in a can)
Ÿ
STICKLERS Clean STIXX MCC-EB12 - Expanded Beam Lens
Disconnect both cable ends for safety
reasons.
Do not stare into beams or view directly with
optical instruments.
Remove the protection cap:
- The Male connector has a lockable cap.
- The Female connector has a pluggable cap.
Check the lenses for contamination.
If there is no visible contamination
®
No cleaning necessary.
A
B
C
D
A
B
Male
Female
Male
Female
C
D