Neumann TLM 102 Operating Manual Download Page 5

9

9

EN

The microphone has a balanced, transformerless 
output. The 3-pin XLR connector has the following 
standard pin assignments:

Pin 1:  0 V/Ground
Pin 2:  Modulation (+phase)
Pin 3:  Modulation (–phase)

1)

  All values are for non-condensing humidity.

The values are valid for clean and well-looked-aft er 
microphones or microphone capsules, respectively. Any 
kind of pollution of capsules and membranes may restrict 
the said values.

2)

  at 1 kHz into 1 kohm rated load impedance.

3)

  re  94 dB SPL

4)

   according to IEC 60268-1; 

CCIR-weighting acccording to CCIR 468-3, quasi peak; 
A-weighting according to IEC 61672-1, RMS

5)

   THD of microphone amplifi er at an input voltage equivalent 

to the capsule output at the specifi ed SPL. 

6)

   according to IEC 61938

9.   Selected Accessories* 

(see photos in appendix) 

Elastic Suspensions

EA 1 ..........................ni ..................Cat.  No.  008449
EA 1 mt .....................blk ................Cat. No.  008450

Auditorium Hanger

MNV 87 ....................ni ..................Cat.  No.  006804
MNV 87 mt ...............blk ................Cat. No.  006806

Stand Mounts, Misc. Mechanical Adapters

DS 120  .....................blk ................Cat.  No.  007343
SG 2..........................blk ................Cat. No.  008636

Table and Floor Stands

MF 4 .........................blk ................Cat.  No.  007337

Foam Windscreens

WS 2 .........................blk ................Cat.  No.  008637

Popscreen

PS 15  .......................blk ................Cat. No.  008472

Power Supply

N 248 .......................blk ................Cat. No.  008537

Connecting Cables

IC 3 mt  ....................blk ................Cat. No.  006543
IC 4 ...........................ni ..................Cat.  No.  006547
IC 4 mt .....................blk ................Cat. No.  006557

Adapter Cables

AC 25  .............................................Cat. No.  006600

Meaning of color codes:
ni = nickel, blk = black, gry = grey

*   Detailed descriptions and additional articles can be found 

in our accessories catalog or at: www.neumann.com

Summary of Contents for TLM 102

Page 1: ...georg neumann gmbh leipziger str 112 10117 berlin germany tel 49 0 30 417724 0 fax 50 headoffice neumann com www neumann com TLM 102 Bedienungsanleitung 2 Operating Manual 6...

Page 2: ...l data section Allow the equipment to adjust to the ambient tem perature before switching it on Do not operate the equipment if it has been dam aged during transport Always run cables in such a way th...

Page 3: ...on which the Neumann logo is located Gradually increase the volume of the connected equipment Set the gain of the connected equipment so that no distortion occurs at the highest sound pres sure level...

Page 4: ...en accessory Plosives Use an appropriate popscreen accessory Transmission of structure borne noise Use a suitable elastic suspension accessory Sound is muffled and reverberant Incorrect directional ch...

Page 5: ...plifier at an input voltage equivalent to the capsule output at the specified SPL 6 according to IEC 61938 9 Selected Accessories see photos in appendix Elastic Suspensions EA1 ni Cat No 008449 EA1 mt...