Neumann TLM 102 Operating Manual Download Page 4

8

8

EN

7.   Troubleshooting

Problem

  

Possible causes

▶ 

 

Solution

Microphone not 
operating

The phantom power supply voltage is 
not switched on at the mixing console 
or at the power supply equipment

Check the corresponding channel settings

The power supply equipment is not 
connected to the power supply line or 
there is no battery

Check the connection to the power supply 
line or check the battery of the power supply 
equipment

No signal 
transmission

The microphone is not connected 
to the correct microphone amplifi er 
input of the subsequent equipment

Check the signal path

If necessary, activate the appropriate input 
on the corresponding channel of the mixing 
console

Distorted sound

Incorrect input sensitivity or gain 
setting of subsequent amplifi er

Decrease the input sensitivity or gain of the 
subsequent amplifi er so as to provide suffi

  cient 

headroom

Wind eff ects

Use an appropriate windscreen (accessory) 

Plosives

Use an appropriate popscreen (accessory) 

Transmission of structure-borne 
noise

Use a suitable elastic suspension (accessory)

Sound is muffl

  ed 

and reverberant

Incorrect directional characteristic

Check to ensure that the microphone is being 
addressed from the correct side, as designated 
by the Neumann logo.

8.   Technical data and 

connector assignments

Permissible atmospheric conditions

1)

 

Operating temperature range ...........0 °C to +70 °C
Storage temperature range ...........–20 °C to +70 °C
Humidity range .....................0 % to 90 % at +20 °C

0 % … 85 % at +60 °C

Acoustical op. principle .............Pressure gradient 

transducer

Directional 
pattern .......................................................Cardioid/
Frequency range ............................ 20 Hz to 20 kHz
Sensitivity

2)

  .............................................. 11 mV/Pa

Rated impedance ....................................... 50 ohms
Rated load impedance ......................... 1000 ohms

Signal-to-noise ratio

3)

CCIR

4)

  ...............................................................73 dB

Signal-to-noise ratio

3)

A-weighted

4)

  ....................................................82 dB

Equivalent noise level, 
CCIR

4)

  ............................................................... 21 dB

Equivalent noise level, 
A-weighted

4)

  ................................................ 12 dB-A

Max. SPL

5)

for THD < 0.5 %  ...........................................  144 dB
Max. output voltage for THD > 5 % ............... 13 dBu
Power Supply ...................................................P48

6)

Current consumption ................................... 3.5 mA
Required connectors ................................... XLR 3 F
Weight ..............................................................210 g
Dimensions  ......................................Ø 52 x 116 mm

94 dBSPL equiv. to 1 Pa = 10 μbar
0 dB equiv. to 20 μPa

Summary of Contents for TLM 102

Page 1: ...georg neumann gmbh leipziger str 112 10117 berlin germany tel 49 0 30 417724 0 fax 50 headoffice neumann com www neumann com TLM 102 Bedienungsanleitung 2 Operating Manual 6...

Page 2: ...l data section Allow the equipment to adjust to the ambient tem perature before switching it on Do not operate the equipment if it has been dam aged during transport Always run cables in such a way th...

Page 3: ...on which the Neumann logo is located Gradually increase the volume of the connected equipment Set the gain of the connected equipment so that no distortion occurs at the highest sound pres sure level...

Page 4: ...en accessory Plosives Use an appropriate popscreen accessory Transmission of structure borne noise Use a suitable elastic suspension accessory Sound is muffled and reverberant Incorrect directional ch...

Page 5: ...plifier at an input voltage equivalent to the capsule output at the specified SPL 6 according to IEC 61938 9 Selected Accessories see photos in appendix Elastic Suspensions EA1 ni Cat No 008449 EA1 mt...

Page 6: ...10 N 248 IC 3 mt EA1 mt DS120 MNV 87 SG 2 MF 4 AC 25 WS 2 PS 15 IC 4 mt...

Page 7: ...11 11 10 Frequenz und Polardiagramme 10 Frequency responses and polar patterns gemessen im freien Schallfeld nach IEC 60268 4 measured in free field conditions IEC 60268 4...

Page 8: ...the product not being in compliance with the technical allow ance in the user manual such as handling errors mechanical spoiling false voltage and using other than the recommended correspondence devi...