NeuLog NUL-218 Quick Start Manual Download Page 7

NEULOG ELECTROCARDIOGRAM LOGGER SENSOR GUIDE

 

 

 

Technical background: 

 
The philosophy behind NeuLog’s plug and play technology is based on 
each sensor’s ability to store its own data due to an internal flash memory 
chip and micro-controller in each plastic NeuLog body.  This technology 
allows the sensor to collect and then store the digital data in the correct 
scientific units (

o

C, 

o

F, Lux, %, ppm, for example). 

 
The  sensor  is  pre-calibrated  at  the  factory.  The  built-in  software  in  the 
logger can be upgraded at any time using software. 
 
ECG  sensors  detect  minor  changes  in  electrical  voltage  which  originate  in 
the heart and spread out across the body over a very short amount of time.  
Cells have a resting potential of about 0.9 mV.  A heart beat originates from 
an  electrical  impulse  in  the  Sinoatrial  Node,  often  called  the  natural 
pacemaker.  The electrical potential cascade spreads across the heart.  Using 
three  leads  (left,  right  and  reference)  the  heart’s  electrical  voltages  (which 
originated in the heart) is measured.  
 
Although the Neulog ECG  sensor is  not aimed  for  medical  measurements, 
is built as ECG real device. 
 
One  important  feature  is  completely  electrical  isolation  from  the  USB  and 
the computer to which it is connected.  
 
The power supply is isolated and transferred by transformers. 
 
The signals are converted and transmitted by optical couplers. 
 
 
 
 

Maintenance and storage: 

 

 

Never submerge the NeuLog plastic body in any liquid. 

 

Do not allow liquid into the ECG sensor’s body. 

 

After use, gently wipe away any foreign material from the ECG sensor. 

 

Store in a box at room temperature out of direct sunlight. 

 
 

Warranty: 

 
We  promise  to  deliver  our  sensor  free  of  defects  in  materials  and 
workmanship  for  a  period  of  3  years  from  the  date  of  purchase.  Our 
warranty  does  not  cover  damage  of  the  product  caused  by  improper  use, 
abuse,  or  incorrect  storage.  Sensors  with  a  shelf  life  such  as  ion  selective 
proves have a warranty of 1 year. Should you need to act upon the warranty 
please contact your distributor. Your sensor will be repaired or replaced. 

 

Thank you for using NeuLog! 
 

 

 
Flexible, simple, fast, forward thinking. 
W

www.neulog.com

 

E

[email protected]

 

A: 850 St Paul Street, Suite 15, Rochester, NY 14605 
P: 1.866.553.8536 
 
 
 
V10012013 

Summary of Contents for NUL-218

Page 1: ...e waves frequencies and periods Therefore what you will see on the Y axis is signal intensity while the X axis shows time Electrocardiograms The heart undergoes a very complex process of electrical ac...

Page 2: ...of the left arm and the right arm in reference to this electrode and to amplify the difference between them This is how it is done in NUL 218 Leads Black Reference Red Left Yellow Right In order to p...

Page 3: ...to find the sensor 7 Select the On line experiment button this will open a graph below 8 Click on the Module setup button located on the ECG sensor icon in the module window to change the sensor sett...

Page 4: ...s not auto detect the sensor s select Search for sensors 13 Once the sensor is found you will see an icon on the left side of the screen for the ECG sensor The icon will display real time data 14 Clic...

Page 5: ...t settings view quick start procedure section for your chosen device in this document 4 After the experiment has concluded when the Start Stop button is pressed again or the data collection period end...

Page 6: ...plastic ergonomic case Push button switch for Start Stop experiments in off line mode LED indicator of experiment status blinks while collecting data ECG probe attached to sensor body by a durable ru...

Page 7: ...asured Although the Neulog ECG sensor is not aimed for medical measurements is built as ECG real device One important feature is completely electrical isolation from the USB and the computer to which...

Reviews: