NeuLog NUL-218 Quick Start Manual Download Page 1

NEULOG ELECTROCARDIOGRAM LOGGER SENSOR GUIDE

 

 

 

NeuLog electrocardiogram logger sensor 
NUL-218 

 
The  NeuLog  electrocardiogram  sensor  can  be  used  for  any  science 
experiment or activity that can utilize heartbeat data such as in the fields of: 
Biology, Physiology, Human medicine, Psychology, etc. 
 
An  electrocardiogram  is  a  very  commonly  used  medical  device  which 
measures and graphs the heart’s electrical activity.  Every single heartbeat is 
a  very  complex  event  which  involves  many  anatomical  locations 
undergoing  changes  in  their  electrical  charges.    A  depolarizing  cascade 
event  originates  in  the  Sinoatrial  Node,  which  is  often  referred  to  as  the 
natural pacemaker, and travels throughout the rest of the heart. 
 
The sensor comes pre-calibrated so you can start experimentation right out 
of the box using this guide.  
 
Hundreds of possible experimental subjects that can be done with the NUL-
218  sensors  are:  electrical  impulses,  heart  rate  monitoring,  human 
physiology,  muscle  physiology,  heart  rate  changes  to  stimuli,  and  many 
more. 
 
The ECG sensor uses the following unit of measure: 

 

Arbitrary  analog  units  (Arb):    An  arbitrary  unit  to  demonstrate 
waves,  frequencies,  and  periods.    Therefore  what  you  will  see  on 
the Y-axis is signal intensity, while the X-axis shows time. 

 
 
 

Electrocardiograms: 

 
The heart undergoes a very complex process of electrical activity; this is the 
basis for how electrocardiograms work.  As the heart’s muscles contract, the 
cells are electrically depolarized which causes a cascade of depolarization to 
flow across the heart – contracting the heart’s muscle fibers.   
 
During  a  heartbeat  a  complex  series  of  events  happens  which  begins  with 
the  cells  resting  potential  at  roughly  -90mV  (millivolts).    The  hearts 
Sinoatrial Node begins the cascade by depolarizing  – creating an electrical 
voltage.    The  electrical  signal  travels  to  the  right  atrium  and  almost 
immediately  to  the  left  atrium.    Because  the  atria  and  the  ventricles  are 
insulated from each other by a special type of cell which acts as an electrical 
insulator,  the  signal  is  picked  up  in  another  cluster  of  cells  called  the 
Atrioventricular Node located in the right atria.  The  signal is carried by a 
special type of fibers - the Bundle of His into the ventricles.  Purkinje Fibers 
rapidly  spread  the  electrical  depolarization  cascade  throughout  the 
ventricles.    The  entire  event  takes  some  time  to  complete.    The  graph  is  a 
visual demonstration of the heart’s relative charge at any given point during 
heartbeats. 
 
 
 
 
 
 
 
 

Summary of Contents for NUL-218

Page 1: ...e waves frequencies and periods Therefore what you will see on the Y axis is signal intensity while the X axis shows time Electrocardiograms The heart undergoes a very complex process of electrical ac...

Page 2: ...of the left arm and the right arm in reference to this electrode and to amplify the difference between them This is how it is done in NUL 218 Leads Black Reference Red Left Yellow Right In order to p...

Page 3: ...to find the sensor 7 Select the On line experiment button this will open a graph below 8 Click on the Module setup button located on the ECG sensor icon in the module window to change the sensor sett...

Page 4: ...s not auto detect the sensor s select Search for sensors 13 Once the sensor is found you will see an icon on the left side of the screen for the ECG sensor The icon will display real time data 14 Clic...

Page 5: ...t settings view quick start procedure section for your chosen device in this document 4 After the experiment has concluded when the Start Stop button is pressed again or the data collection period end...

Page 6: ...plastic ergonomic case Push button switch for Start Stop experiments in off line mode LED indicator of experiment status blinks while collecting data ECG probe attached to sensor body by a durable ru...

Page 7: ...asured Although the Neulog ECG sensor is not aimed for medical measurements is built as ECG real device One important feature is completely electrical isolation from the USB and the computer to which...

Reviews: