LIS-SDI   Rev. 

 

 

  network-electronics.com 

14 

LIS-SDI card will enter programming mode. This causes no harm, but the card will not work 
in this mode.  
Factory setting is switch 10 in 

on

 position. 

 

Switches 5, 6, 7 and 9 - Reserved 

These switches are reserved for future expansion, and should always be in the 

off

 position. 

Factory setting is switch 5, 6, 7 and 9 in 

off

 position. 

 

Switch 8 - Reset to factory default 

LIS-SDI contains EEPROM that is affected by your choices. Switch 8 is implemented to reset 
the EEPROM to factory default. Its use is shown in Table 2. 
 
Action Comment 
Power down. 

 

Turn switch 8 

on

.  

Power up. 

LIS-SDI enters a special state where the EEPROM is restored to factory default 
values. This is flagged by the LEDs, they are all yellow. 

Power down. 

 

Turn switch 8 

off

.  If you want the DIP switches to be placed in the factory default position, this is the 

time to do so: Turn switches 1 through 9 to the 

off

 position. Switch 10 should, as 

always, be turned to the 

on

 position. 

Power up. 

The card EEPROM is now reset to factory settings. 

Table 2: Method to restore the LIS-SDI card to factory settings. 

Remember to let some seconds pass by each time you power down, to allow capacitors to be 
fully discharged. 
 
 

Switch 1 - Manual mode 

Switch 1 is the manual mode switch. If 

on

, the LIS-SDI is primarily assumed to be operated 

with switches alone. If 

off

, the LIS-SDI is assumed to be used with a GYDA controller.  

Factory setting is switch 1 in 

off

 position. 

 

With switch 1 off 

While in automatic mode, switches 2, and 3 are without any effect. 
 

With switch 1 on 

In manual mode, the functionality of switches 2, and 3 is as follows: 
 

Switch 2 

Switch 2 turns on/off disabling of EDH in the output SDI. With switch 2 

off

, the EDH is 

included in the SDI signal, with switch 2 

on

, EDH is not included. 

Factory setting is switch 2 in 

off

 position. 

 

Switch 3 

Switch 3 turns on/off the line sync mode. With switch 3 

off

,  the video output is delayed half a 

line with respect to the first SDI input detected. The LIS-SDI tolerates upstream video 
switching on the input SDI. The deglitching only works if any of the different SDI inputs has 
a phase difference not more than half a line from any of the other SDI inputs that will be used 
with the LIS-SDI. 

Summary of Contents for Flashlink LIS-SDI

Page 1: ...network electronics com SDI Line Synchroniser Rev 2 Flashlink User Manual LIS SDI...

Page 2: ...com Current revision of this document is the uppermost in the table below Revision Replaces Date Change Description 2 1 2007 10 26 New front page 1 0 2007 09 11 Added Materials Declaration and EFUP up...

Page 3: ...t signal in such a way that the delay through the card is between 41 samples and 1 line and 41 samples See section 4 3 Used as a video deglitcher 1 Attach SDI input and SDI output s to the backplane m...

Page 4: ...cription 10 4 1 Data path 10 4 2 EEPROM 10 4 3 Two modes of operation 10 4 4 Power up sequence 11 4 5 When an input signal is lost 11 4 6 Warm up time 11 5 Module status 11 5 1 GPI General Purpose Int...

Page 5: ...Environmentally friendly use period 22 Recycling information 23 EC Declaration of Conformity 24 List of figures Figure 1 Simplified block diagram of the LIS SDI card 6 Figure 2 FRS SDI C1 connector m...

Page 6: ...relative to Black Burst signal The LIS SDI deglitches the digital signal when upstream switching is performed It is possible to correct false F Field V Vertical blanking and H Horisontal blanking bit...

Page 7: ...on Automatic up to 35 dB 300 m Belden 8281 Return loss 15 dB Black Burst input Input signal SMPTE 170M PAL ITU 624 4 Return loss 35 dB up to 5 75 MHz Digital Serial Output Output format 270 Mb s scram...

Page 8: ...scribed in the user manual for the sub rack frame FR 2RU 10 2 This manual is also available from our web site http www network electronics com 3 2 Correspondence of connectors and signals The FRS SDI...

Page 9: ...LIS SDI Rev 2 network electronics com 9 Figure 3 LIS SDI simplified silkscreen figure not to scale...

Page 10: ...n two modes with or without linesync switch 3 or lsync on off command When the linesync mode is off the card is used as a deglitcher Then the output phase is not adjustable It is recommended that the...

Page 11: ...s done whether it is by switches or GYDA the state is stored in the EEPROM as soon as it is detected 4 5 When an input signal is lost If SDI input disappears If the SDI input disappears the output wil...

Page 12: ...fundamental probably electrical error has been detected The card is set in a passive state so that it does not disturb other cards in the rack While powering on the CardState LED will light red for ap...

Page 13: ...lways be in the On position The switches are discussed in logical rather than numerical order Switch Function Comment 1 Manual mode on off When on enables switches 2 3 and 4 2 EDH disable on off When...

Page 14: ...et to factory settings Table 2 Method to restore the LIS SDI card to factory settings Remember to let some seconds pass by each time you power down to allow capacitors to be fully discharged Switch 1...

Page 15: ...e LIS SDI will generate EDH information on the correct EDH line after the vertical shifting 7 Pushbuttons LIS SDI contains three pushbuttons 7 1 Reset The lower pushbutton is a reset switch see Figure...

Page 16: ...rconnect see the documentation of FR 2RU 10 2 The available commands are shown in Table 3 Command Response Comment Yes The Hello command info Yes Gives back the card state EDH on xxxxOK Turn on EDH in...

Page 17: ...nfo command is composed by many minor lines fully specified in Table 4 In general when a condition is normal it is not reported For instance EDH will normally be enabled it is only when it is disabled...

Page 18: ...urst is not used as an output timing reference only as a frequency reference The xxx and xxxx shows what the reference would have been if lsync were enabled TRS Replace on The incoming video SYNC word...

Page 19: ...S SDI Rev 2 network electronics com 19 edh d Error detected here flag is detected d is a decimal number from 0 to 65535 for all the 15 EDH counters above Table 4 The info command broken up in componen...

Page 20: ...eed performance specification under the following environmental conditions Operating room temperature range 0 C to 40 C Operating relative humidity range up to 90 non condensing 2 The equipment will o...

Page 21: ...anty The warranty terms and conditions for the product s covered by this manual follow the General Sales Conditions by Network Electronics ASA These conditions are available on the company web site of...

Page 22: ...nce on how the EFUP is to be calculated is not finalised at the time of writing See http www aeanet org GovernmentAffairs qfLeOpAaZXaMxqGjSFbEidSdPNtpT pdf for an unofficial translation of the draft g...

Page 23: ...ugh our web site http www network electronics com Please contact Network Electronics Customer Support for assistance with recycling if this site does not show the information you require Where it is n...

Page 24: ...UMBER S LIS SDI DESCRIPTION SDI Line Synchroniser DIRECTIVES this equipment complies with LVD 73 23 EEC EMC 89 336 EEC HARMONISED STANDARDS applied in order to verify compliance with Directive s EN 55...

Reviews: