LB-EO Rev.
3
DIP switch configuration must be set according to the table below:
Switch
#
Label
Function,
DIP = ON
Function,
DIP = OFF
Comment
1 AGC
Automatic
gain
control
Manual gain
control
2
R/S
Run AGC
Sample AGC level
Only valid in Manual gain
control
3 LNB
Enable
power
supply for LNB
Disable power
supply for LNB
4 H/V
Horizontal
polarization
Vertical polarization Sets voltage on LNB
5 LLC
Line
length
compensation on
Line length
compensation off
If on, output voltage from card
to LNB will increase by 1 volt.
Set to ON when using long
cables (cable more than approx
3 ohms DC resistance in cable)
6
H/L
High band
Low band
22kHz tone control
7
GPI
H/V and H/L
controlled by GPI
H/V and H/L
controlled by DIP
or GYDA
When GPI is set, DIP 4 and 6
will be disregarded
8 OVR
Override
GYDA
control. Config.
with DIP switch
GYDA control.
Config. with GYDA
Select configuration from GYDA
All DIP switches are off when pointing towards the release handle.
network-electronics.com | 7