NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 

 

69

 

5.3 CPU-to-RACKMUX Ethernet Crossover Cable  

In order to make a direct connection between a CPU and the ETHERNET connector of the RACKMUX, a crossover cable must be 
used.  The cable is made with CAT5 cable terminated with RJ45 connectors and wired according to the chart below. 
 

 
 

Pin assignment at  

Standard End 

Wire Color 

Pin assignment at 

Crossed End 

 1 

White/

Orange

 3 

 2 

Orange 

 3 White/

Green

 1 

 4 

Blue 

 5 White/

Blue

 5 

 6 

Green 

 7 White/

Brown

 7 

 8 

Brown 

 
 
 
 
 
 
 

5.4 Serial Port Cabling 

The SERIMUX simplifies cabling. The RJ45 8-pin configuration matches all SUN and Cisco RJ45 console port configurations, 
enabling CAT 5 cabling without pinout concerns. Three DB-25 and one DB-9 adapters come in the package. A DB-25 male, a DB-
25 female, and a DB-9 adapter support console management applications. A DB-25 male adapter provides a modem 
connection. See the cable adapter information that follows later in this chapter. 
 

Note: The cable length restrictions common to RS-232 cables apply to the SERIMUX serial cable as well. 

 

5.5 Serial Port Pinouts 

The SERIMUX uses an RJ45 connector for serial ports. Pin assignments are as follows: 

 

SERIMUX Ports 
Pin 

Description 

1 CTS 
2 DSR 
3 RxD 
4 GND 

DCD: Note Inbound signal can also be used as a second ground. 

6 TxD 
7 DTR 
8 RTS 

 

R

8
-

T

7
+

R

6
-

T

5
+

R

4
-

T

3
+

R

2
-

T

1
+

Mating face of an RJ45 Female

Standard 
End

Crossed 
End

Crossover Cable

Summary of Contents for NTI SERIMUX-SECURE 8

Page 1: ...S16 8 Rack Mount Console Terminal Drawer with Console Switch Installation and Operation Manual RACKMUX Series NETWORK TECHNOLOGIES INCORPORATED Tel 330 562 7070 Fax 330 562 1999 1275 Danner Dr Aurora...

Page 2: ...in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written consent of Network Technologies Inc 1275 Danner Dr...

Page 3: ...ministrator 12 3 1 2 Port List 13 3 1 3 Port Settings 14 3 1 3 1 Port serial settings 16 3 1 3 2 Modem settings 18 3 1 3 3 Port data buffer 19 3 1 4 User List 20 3 1 5 User Settings 21 3 1 5 1 Port ac...

Page 4: ...Setup for LPD 61 4 6 3 LPD printing 62 4 6 4 Setup for TFTP 62 4 6 5 TFTP Printing 62 4 7 On Screen Display OSD 63 4 7 1 Standard Controls 63 4 7 2 OSD Control Menu 63 4 7 2 1 OSD Main Menu 63 4 7 2...

Page 5: ...re 17 Administrator s Advanced settings menu 23 Figure 18 Firmware menu 24 Figure 19 The SERIMUX is waiting to save its firmware 25 Figure 20 A user with limited host port access 26 Figure 21 User mai...

Page 6: ...ver session is preserved by the terminal Terminal sessions can be switched via hot keys When using the Ethernet telnet connection the Terminal Drawer can be connected to multiple servers via an Ethern...

Page 7: ...erial console are connected to user ports The SERIMUX Console Switch supports two operator levels user and administrator Users login at user ports and connect to serial devices attached at host ports...

Page 8: ...Serial cable with at least one RJ45 male end for connection to the Console Switch from each device to be connected See Interconnection Cable Wiring Method on page 29 for cable pinout Note In order to...

Page 9: ...Lock keyboard feature is ON 10 Fn LED illuminates when the number pad features are enabled 11 Keyboard for manual data entry and computer control 12 LCD Display for viewing the video signal from the...

Page 10: ...the top holes in the front bracket flanges line up with the holes marked in step 1 Secure the front brackets on the drawer to the front cabinet rails using 10 32x3 4 screws and cage nuts supplied Be...

Page 11: ...communication equipment DCE i e modem and data terminal equipment DTE i e CPU each having different connector pin assignments The cable adapters see Materials on page 3 make the proper connections 2 I...

Page 12: ...UX may be directly connected to PC using a CAT5 Crossover cable See page 67 for specifications 1 5 Power Up The RACKMUX 1 Connect the AC adapter to a power source 2 Using the key unlock the drawer and...

Page 13: ...n the ALT key and press the Esc key to enter Setup mode When entering Setup any text on the screen temporarily disappears and the main SETUP directory appears See Figure 5 When leaving the Setup mode...

Page 14: ...ettings are not saved before exiting Setup any new selections will be lost when the RACKMUX is powered down To save Setup selections depress the Spacebar to change the save field at the right side of...

Page 15: ...NTI RACK MOUNT CONSOLE TERMINAL WITH CONSOLE SWITCH 10 2 To connect to an attached CPU enter the number of the port the CPU is connected to and press Enter Figure 6 Startup Accessible host list...

Page 16: ...RIMUX supports 2 operator levels administrator and user each with separate password protection for security The administrator logs in using an administrator password see next page for login procedure...

Page 17: ...dministrator main menu will appear for user ROOT on port 0 Note This will only enter the administrator mode if the administrator password has not yet been changed from NTI FYI If SERIMUX is not at ini...

Page 18: ...f another port Pxx connected to that port If the administrator is logged in Adm will be displayed U H Port type User or Host Mdm Modem connection status Y if modem is connected if not BaudRate Port tr...

Page 19: ...based on the administrator s timeout setting not based on the user s timeout setting If two ports are connected to each other and one port has a lower timeout setting than the other the lower setting...

Page 20: ...trator consoles Reset Port settings to default Restores factory default port settings A confirmation Y will be required When 3 is pressed to change the in band disconnect sequence the choices provided...

Page 21: ...alues 3 1 3 1 2 Data bit The data bit number can be 5 6 7 8 except for port 0 7 or 8 To modify the data bit number press 2 then the bit number 5 6 7 8 3 3 1 3 Stop Bit The stop bit number can be 1 2 1...

Page 22: ...en a modem is attached to the port the DTR line will be pulsed on port disconnection disregarding this parameter value To modify the DTR line behavior on port disconnection press 8 then H or L or P re...

Page 23: ...try the default values first refer to the manual s for the modems otherwise Figure 12 Modem settings menu The administrator can initialize a modem attached to a SERIMUX port or disconnect the modem T...

Page 24: ...dministrator can see the last 1016 characters received and transmitted to from any port This way the administrator can verify that data was transferred properly between ports Figure 13 Port data buffe...

Page 25: ...bled Adm Displays if user has administrative rights Y yes no Port access Displays what ports the user has access to Log Identifies what port the user is logged into if any Con Identifies what port the...

Page 26: ...s 0 never Administrator privileges Enable administrative privileges for user Y to enable any other character to disable Port access Define ports user has access to Displays user s Port access list Fig...

Page 27: ...to memory press asterisk to start the paste function Three options are available Option Description Y apply the settings in memory to the current user shown A apply the user settings in memory to all...

Page 28: ...a login by a valid user with access rights will be required 3 1 6 1 Change administrator password For security purposes the administrator should change the factory default administrator password to a...

Page 29: ...ailable at this time 3 Save current firmware Save present firmware in SERIMUX to binary file 3 1 6 2 1 Load new firmware To upgrade the firmware that controls the Console Switch as soon as improved ve...

Page 30: ...col receive the binary file for example the HyperTerminal for Windows Transfer Receive File command to transfer the SERIMUX firmware to a binary file When saving the file choose a directory to place t...

Page 31: ...ust press Spacebar or Enter after power ON the TERMINAL or opening the connected terminal emulator After login the user may connect to an allowed host port or view host status and parameters The user...

Page 32: ...ossible Function Keystroke Connect to host port 1 xx Enter where xx is the port index number Display Accessible host list 2 Enter Display accessible host and user ports and info about each 3 Enter Log...

Page 33: ...to the port Usr Hst Port type user or host Modem Yes if modem is attached if not BaudRate Receiving and transmitting speed of the port Serial Character size parity and stop bit number Flow Defines flo...

Page 34: ...mber of functions are possible 3 2 4 1 Terse mode commands Connect to port Send or type in C xx Enter where xx is the port index number The answer will be OK CR LF LF FF If an error occurs i e the por...

Page 35: ...login the administrator to a port other than port 0 the administrator must first configure the desired port as a user port see page 15 By default all ports other than 0 are configured as host ports 3...

Page 36: ...range Ctrl Q 17 Xoff character any ASCII nonprintable character 0 31 range Ctrl S 19 Inter character delay except port 0 no delay allowed on port 0 1 60 milliseconds none None Line break receive allow...

Page 37: ...er changes into memory before returning the terminal to the normal operating mode Settings changed will effect the operating environment until the TERMINAL is powered down Setting changes will only be...

Page 38: ...es the terminal to clear the screen when executing a command to change the number of columns Screen Saver OFF 1 2 3 4 5 6 Sets the screen saver to activate after the specified number of minutes Page L...

Page 39: ...event loss of data Key Code sets the terminal to send normal ASCII characters ASCII or PC type scan codes for every key up down Scan Scan is only required for the PC Term personality Num Start ON OFF...

Page 40: ...line of periods that mark each column position 1 A tab stop in columns 2 through 78 is shown as a T in the upper line of periods 2 A tab stop in columns 79 through 132 is shown as a T in the lower li...

Page 41: ...IP address is used to communicate with other networks If a gateway is not being used this option should be blank Remote IP 0 B Address are for any remote CPU or devices that the terminal will communic...

Page 42: ...ank will be used to map monochrome attributes to color Color Association OFF ON Table 5 Color Setup Menu Option ASCII NOT WY325 WY325 VTXXX ANSI CONSOLE Background The whole data area of the screen wi...

Page 43: ...erline and intensity 2 3 Underline intensity 2 and reverse or blank 1 Cyan Black Red Black Magenta Black Blue Black Black White Black Red Black Magenta Black Blue 3 Normal Reverse or blank 1 Intensity...

Page 44: ...2 Intensity 2 and reverse or blank 1 Underline Underline and reverse or blank 1 Underline and intensity 2 3 Underline intensity 2 and reverse or blank 1 White Black Yellow Black Blue Black Cyan Black...

Page 45: ...low scrolling rate CTRL SHIFT Home cursor and clear page CTRL SHIFT HOME Display page 0 CTRL 0kpd Display page 1 CTRL 1kpd Display next page or active other window 4 PAGE DOWN Display previous page or...

Page 46: ...found at the end of Table 8 on page 46 Table 8 Commands Supported in ASCII Personalities Command Native Wyse ADDS TVI PC FUNCTION Mode WY 50 VP A2 910 925 Term Monitor Mode Monitor mode on ESC U Same...

Page 47: ...CTRL Y Conceal answerback message ESC c Same ENH Send answerback message ESC c Same ENH Turn answerback mode off ESC e SP Same ENH Turn answerback mode on ESC e Same ENH Controlling the Terminal and K...

Page 48: ...isplay off ESC 0 Same CTRL W Cursor display on ESC 1 Same CTRL X 25th line display off ESC e Displaying the Message Fields Extended status line on ESC a Same ENH Standard status line on ESC b Same ENH...

Page 49: ...window down in page ESC w F Same Redefine screen as one window ESC x Same Redefine screen as one window ESC x 0 Same and clear pages Display Attributes Assign display attribute to a ESC A mf attr Sam...

Page 50: ...ESC 9 Received CR mode on ESC e 5 Same ENH ENH ESC 8 Autopage mode off ESC d Same ENH ESC w Autopage mode on ESC d Same ENH ESC v Autoscrolling mode off ESC N Same ENH Autoscrolling mode on ESC O Same...

Page 51: ...unprotected page to ESC attr ENH ENH display attribute Clear unprotected page to spaces ESC Y Same ESC k Same Same from cursor Clear unprotected page to nulls ESC y Same ENH Same Same from cursor Cle...

Page 52: ...ESC d CTRL T CTRL T Bi directional mode on ESC d CTRL CTRL R Auxiliary receive mode off ESC d SPACE Auxiliary receive mode on ESC d Set print terminator ESC p ESC p Define delimiters ESC x ESC x Chara...

Page 53: ...nderline reverse blink invisible Underline reverse blink invisible bank Font Bank a bank Font Bank a 0 Font bank 0 2 Font bank 2 1 Font bank 1 3 Font bank 3 a Holds predefined character set baud Baud...

Page 54: ...ard Style key Enhanced PC key Enhanced PC key Enhanced PC SPACE ESC SHIFT TAB RETURN SHIFT ESC BACKSPACE SHIFT RETURN TAB SHIFT BACKSPACE HOME SHIFT HOME 3 SHIFT 6 SHIFT DELETE s ENTER kpd R PRINT SCR...

Page 55: ...5 46 M 70 e 94 23 6 47 N 71 f 95 24 7 48 O 72 g 96 DEL RUB c Native codes also recognized in WY 50 TVI 910 925 and PC Term personalities and in ADDS VP A2 personality absolute cursor addressing lll On...

Page 56: ...alette 0 Palette 0 4 Palette 4 8 Palette 8 1 Palette 1 5 Palette 5 9 Palette 9 2 Palette 2 6 Palette 6 Palette 10 3 Palette 3 7 Palette 7 parity Parity Bits parity Parity Bits 0 None 2 Mark 1 Odd 3 Ev...

Page 57: ...Dim UL Blink UL Dim Blink UL Rev UL Rev Dim UL Rev Blink UL Rev Dim Blink h i j k x y z Underline UL UL Dim UL Blink UL Dim Blink UL Rev UL Rev Dim UL Rev Blink UL Rev Dim Blink 4 5 ANSI Command Guide...

Page 58: ...0 h Same Display screen CSI 30 l Same Display status line CSI 31 h Same Blank status line CSI 31 l Same Screen saver CSI 32 h Same Screen saver off CSI 32 l Same Cursor steady nonblinking CSI 33 h Sam...

Page 59: ...ttribute 0 Normal all attributes off 25 Blink off 1 Bold blank off 27 Reverse off 4 Underline 28 Blank off 5 Blink 30 Black character 7 Reverse 31 Red character 8 Blank bold off 32 Green character 22...

Page 60: ...Move cursor down n lines CSI n B or CSI n e Same Move cursor right n columns CSI n C or CSI n a Same Move cursor left n columns CSI n D Same Move cursor down cursor n line to column 1 CSI n E Same Mov...

Page 61: ...r Same t Top line number b Bottom line number optional if omitted treated as bottom screen line Controlling Tabs Clear tab stop at cursor CSI 0 g or CSI 2 W CSI 2W Clear all tab stops CSI 3 g or CSI...

Page 62: ...5 S_F5 L C_F5 X C_S_F5 5 F6 A S_F6 M C_F6 Y C_S_F6 6 F7 B S_F7 N C_F7 Z C_S_F7 7 F8 C S_F8 O C_F8 C_S_F8 8 F9 D S_F9 P C_F9 C_ S_F9 9 F10 E S_F10 Q C_F10 C_ S_F10 F11 F S_F11 R C_F11 C_ S_F11 F12 G S_...

Page 63: ...at cursor ESC 5 Same Send answerback message CTRL E Same Suspend transmission CTRL S Same Resume transmission CTRL Q Same More Terminal Control Commands Display screen adjustment pattern ESC 8 Same S...

Page 64: ...om the keyboard press CTRL SHIFT 1 use the 1 on the numeric keypad 3 In VT52 or VT100 modes displays checkerboard character 4 5 2 VT52 Command Guide Table 10 VT52 Mode Escape Sequences Command VT52 Mo...

Page 65: ...t print the data file immediately upon receiving it the print option specified in the control file cannot take affect To install the printer server function of Ethernet Print Terminal the first step i...

Page 66: ...es to be able to read from or write to the directory e g If it works on a BSD UNIX host and makes the directory usr spool ETPS1 created in step 3 available then follow these three procedures chown dae...

Page 67: ...e BSD UNIX system run the setup procedure under Setup for LPD on page 61 Otherwise run the Setup for LPD omitting step 6 4 6 5 TFTP Printing Before using TFTP printing the Ethernet Print Terminal need...

Page 68: ...is highlighted pressing the Menu button will select it Figure 26 OSD Controls The Select button is used to make selections within the OSD menus when the OSD menu is ON When the OSD menu is OFF the Se...

Page 69: ...With either the RED GREEN or BLUE sections highlighted use the Up or Down arrow to move between them press the Select button to choose the option to adjust Then use the Up or Down Arrow to adjust the...

Page 70: ...r can be idle before the OSD menu automatically exits adjustable from 10 to 60 seconds LANGUAGE the language that the OSD menus will be presented in With the item highlighted use the Up or Down arrow...

Page 71: ...Fn key This section will describe which keys have multiple functions and how to enable them Figure 27 Keyboard Layout ESC F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 NUMLCK PRT SC INSERT DELETE SYS RQ PAU...

Page 72: ...e Fn and NumLock LEDs illuminated pressing some standard keys will result in displaying characters as indicated in the chart below Table 11 Number Pad Keys Standard Key Displayed when NumLock is ON Fu...

Page 73: ...aracter matrix 7x12 dot matrix in 10x16 cell with 3 dot descenders Screen size 80x25 Page length 1 2 or 4 screens multiple screen page length reduces maximum number of possible telnet sessions Cursor...

Page 74: ...SUN and Cisco RJ45 console port configurations enabling CAT 5 cabling without pinout concerns Three DB 25 and one DB 9 adapters come in the package A DB 25 male a DB 25 female and a DB 9 adapter supp...

Page 75: ...s RJ45 Signal DB 25M Signal 1 CTS Connected to 4 RTS 2 DSR 5 DCD Connected to 20 DTR 3 RxD Connected to 2 TxD 4 GND Connected to 7 GND 6 TxD Connected to 3 RxD 6 DCD 7 DTR Connected to 8 DSR 8 RTS Con...

Page 76: ...ed to 5 CTS DB 25 Male Modem Adapter NTI P N DB25M RJ45F C DB 25 Male Modem to RJ45 Pin Assignment RJ45 Signal DB 25M Signal 1 CTS Connected to 5 CTS 2 DSR Connected to 6 DSR 3 RxD Connected to 3 RxD...

Page 77: ...Compatible with the IBM PC parallel port Pin Signal Mnemonic Direction 1 Strobe Out 2 Data bit 0 Out 3 Data bit 1 Out 4 Data bit 2 Out 5 Data bit 3 Out 6 Data bit 4 Out 7 Data bit 5 Out 8 Data bit 6...

Page 78: ...IN Front View of RACKMUX T15 RS16 Slotted holes for securing terminal drawer to rack 15 LCD Display 2 1 9 IN Rear View of RACKMUX T15 RS16 SERIAL PARALLEL ETHERNET 12VDC CONNECTOR RJ45 SERIAL DEVICE C...

Page 79: ...63 password 11 port access 22 Port List 13 Port serial settings 16 port settings 14 printer connection 6 programmable keys 36 quick start 8 Remote System Control 1 reset button 4 30 ROOT 12 RS 232 Em...

Reviews: