Network Technologies ENVIROMUX PWR-RMT-RBT Installation And Operation Manual Download Page 8

Page 5

Initial Configuration 

The iBoot Setup Utility supplied on the distribution CD provides the easiest means to find and
configure your iBoot for use.  It can discover all the iBoots on your network, display the current IP 
address of each, and allow setting of any valid IP address.  The Setup Utility is available on the 
distribution CD.

Install and run the iBoot Setup Utility: 

1. Load the iBoot CD. (The CD supports

only Windows)

2. Click on Setup.exe 
3. Install the iBoot Setup Utility 
4. Run the iBoot Setup Utility 

Note:  The IP address can only be set within the 
first two minutes of powering up the iBoot, and 
requires a power restart of the iBoot after setting 
the IP address.  Make sure you have physical 
access to the iBoot before attempting to set the 
IP Address.  The Setup Utility will only work with 
iBoots on the same local subnets as the iBoots. 

Once the iBoot Setup Utility is run, click on 
Discovery to display all the iBoots on your 
network.  New iBoots will display with the name 
Set Location and have either the factory default 
IP address of 192.168.1.254 or an IP address 
that was automatically assigned by the DHCP 
server on your network.  If the IP address was 
assigned by a DHCP server, no changes to the
IP Address are required. 

The IP address field also indicates the IP port 
that is used by the iBoot.  The standard port for 
web browser control is factory default Port 80. 

Change the IP Address 

1. Click on the row containing the iBoot to

be set.  The row will become highlighted.

2. Click on the Set IP Address button. 
3. Enter the new IP Address into the form. Click OK when done. 
4. A confirmation box is displayed.  Click OK to clear the box. 
5. Power cycle the iBoot to finish the process.  A reminder of which iBoots that require this 

power down – power up procedure are indicated by a  .

*

Summary of Contents for ENVIROMUX PWR-RMT-RBT

Page 1: ...PWR RMT RBT Remote Power Reboot Switch Installation and Operation Manual ENVIROMUX Series NETWORK TECHNOLOGIES INCORPORATED Tel 330 562 7070 Fax 330 562 1999 1275 Danner Dr Aurora OH 44202 www networ...

Page 2: ...75 Danner Drive Aurora Ohio 44202 CHANGES The material in this guide is for information only and is subject to change without notice Network Technologies Inc reserves the right to make changes in the...

Page 3: ...Man095 Rev 10 23 07...

Page 4: ...Man095 Rev 10 23 07...

Page 5: ...pter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to rest on the power cord Do not locate this product where...

Page 6: ...bilities iBoot features several other means to operate automatically or under computer control Auto Ping The Auto Ping feature allows the switch to automatically detect failed Dual equipment and perfo...

Page 7: ...lectrical standards If the device to be powered uses an IEC320 receptacle and detachable power cord an IEC to IEC extension cord can be used The iBoot can be connected to a power strip to allow simult...

Page 8: ...work with iBoots on the same local subnets as the iBoots Once the iBoot Setup Utility is run click on Discovery to display all the iBoots on your network New iBoots will display with the name Set Loca...

Page 9: ...Boot Once an IP address is assigned you must check the DHCP server or use the iBoot Setup Utility to see what address is assigned to iBoot If you set the IP address using another method the address be...

Page 10: ...eturns host not responding 4 times then the address has not been programmed properly The process must be run within two minutes of powering up the iBoot and not have been set by a DHCP server Check th...

Page 11: ...abort a power cycle click on either Power On or Power Off buttons iBoot will assume the status selected If the Auto Ping or Heartbeat Features are in use then the page will also display the current s...

Page 12: ...If the new port is 9105 then use address http 192 168 1 254 9105 CallerIP 1 and 2 CallerIP provides IP address filtering to insure only authorized personnel access the iBoot You can set two IP address...

Page 13: ...ibootctl exe or direct messaging Power On Follow Upon triggering iBoot will power on When the ping response returns iBoot will power off Power Off Latch Upon triggering iBoot will power off and remain...

Page 14: ...t not to the Setup functions When this password is used the main screen will not have a link to Setup The System Password allows access to both the Main Screen and the Setup Screen The default for bot...

Page 15: ...t Confirmation The heartbeat can be generated in any of several ways A Windows executable program that will run as a tray applet that will transmit heartbeats at a steady interval to an iBoot A Window...

Page 16: ...the heartbeat returns and is lost again Using Heartbeat Monitor With Heartbeat operational the main iBoot page will display the current status of this feature The status will be OK to indicate that i...

Page 17: ...ir responses Command Format All of iBoot s commands follow the following format esc password esc action cr esc ASCII Escape character 1b hex or 27 decimal password The 1 to 10 character Power Control...

Page 18: ...0 A Max at 210 240 VAC Compliance UL cUL UL60950 Listed I T E File No E225914 CE Directives 89 336 EEC 92 31 EEC and 93 68 EEC EN 60950 3rd Edition EN 55022 1998 Class B FCC Part 15 Class B Network Du...

Reviews: