background image

CWDM-1-8/-9-16/1-8-L/9-16-L/1-8-M/9-16-M  

Rev. 

 

3.3

 

9-16 channel system 

Using the upgrade port of the CWDM-9-16 enables to have up to 16 wavelengths on a 
single fibre. 

Each set of 8 channels must first be connected like described in chapter 3.2, figure 3. 

 

                 

 

Figure 5: 16-channel CWDM filters connected to main fibre 

 

 
 

 

network-electronics.com | 7 

Summary of Contents for Flashlink CWDM-1-8

Page 1: ...network electronics com 8 channel CWDM multiplexer and demultiplexer multi mode M low loss L Rev 2 Flashlink User Manual CWDM 1 8 9 16 CWDM 1 8 M 9 16 M CWDM 1 8 L CWDM 9 16 L...

Page 2: ...rent revision of this document is the uppermost in the table below Rev Repl Date Sign Change description 2 1 2007 09 01 RS Complete restructuring of user manual adding specifications for L low loss an...

Page 3: ...CWDM filter 6 3 2 1 8 channel system 6 3 3 9 16 channel system 7 4 Laser safety precautions 8 General environmental requirements for Network Electronics equipment 9 Product Warranty 10 Appendix A Mat...

Page 4: ...and one from 1270 to 1410nm with an upgrade port By use of the upgrade port up to 16 optical signals can be run over a single fibre The units are passive and all optical devices requiring no power su...

Page 5: ...max for 16 channels Insertion loss common to upgrade 1dB max single mode Channel Spacing 20nm Passband 13nm min Transmission circuit fibre 9 125um single mode Adjacent Channel Isolation 25dB min Non...

Page 6: ...r rail aligns with the card rail in the subrack it should slide easily into place Lock it with 4 M2 5x8mm screws Figure 2 CWDM 1 8 mounted in a Flashlink subrack 3 2 1 8 channel system Connect each of...

Page 7: ...em Using the upgrade port of the CWDM 9 16 enables to have up to 16 wavelengths on a single fibre Each set of 8 channels must first be connected like described in chapter 3 2 figure 3 Figure 5 16 chan...

Page 8: ...ul when connecting disconnecting fibre pigtails ends Never look directly into the pigtail of the laser fibre Never use microscopes magnifying glasses or eye loupes to look into a fibre end Use laser s...

Page 9: ...performance specification under the following environmental conditions Operating room temperature range 0 C to 50 C Operating relative humidity range 90 non condensing 2 The equipment will operate wit...