background image

CWDM-1-8/-9-16/1-8-L/9-16-L/1-8-M/9-16-M  

Rev. 

 

Network Electronics ASA 

Thorøya 

P.O. Box 1020 

N-3204 Sandefjord, Norway 

Phone: +47 33 48 99 99 

Fax: +47 33 48 99 98 

Email: 

[email protected]

 

www.network-electronics.com

Support Phone: +47 90 60 99 99 

 

 

 

 

 

 

 

 

 

 

 

Revision history 

Current revision of this document is the uppermost in the table below. 

Rev. Repl. 

Date 

Sign 

Change 

description 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2007-09-01 

RS 

Complete restructuring of user manual, adding 
specifications for –L (low loss) and –M (multi mode) 
versions, removed description of 4-channel CWDM.  
Updated Materials Declaration and added EFUP. 

2003-05-14 

RS 

Corrected interconnection of sub-racks with RS-422 

0 A 

2002-11-19 

RS 

Product 

release 

A - 

2002-10-01 

RS 

Preliminary 

version 

 

 
 

 

network-electronics.com | 2 

Summary of Contents for Flashlink CWDM-1-8

Page 1: ...network electronics com 8 channel CWDM multiplexer and demultiplexer multi mode M low loss L Rev 2 Flashlink User Manual CWDM 1 8 9 16 CWDM 1 8 M 9 16 M CWDM 1 8 L CWDM 9 16 L...

Page 2: ...rent revision of this document is the uppermost in the table below Rev Repl Date Sign Change description 2 1 2007 09 01 RS Complete restructuring of user manual adding specifications for L low loss an...

Page 3: ...CWDM filter 6 3 2 1 8 channel system 6 3 3 9 16 channel system 7 4 Laser safety precautions 8 General environmental requirements for Network Electronics equipment 9 Product Warranty 10 Appendix A Mat...

Page 4: ...and one from 1270 to 1410nm with an upgrade port By use of the upgrade port up to 16 optical signals can be run over a single fibre The units are passive and all optical devices requiring no power su...

Page 5: ...max for 16 channels Insertion loss common to upgrade 1dB max single mode Channel Spacing 20nm Passband 13nm min Transmission circuit fibre 9 125um single mode Adjacent Channel Isolation 25dB min Non...

Page 6: ...r rail aligns with the card rail in the subrack it should slide easily into place Lock it with 4 M2 5x8mm screws Figure 2 CWDM 1 8 mounted in a Flashlink subrack 3 2 1 8 channel system Connect each of...

Page 7: ...em Using the upgrade port of the CWDM 9 16 enables to have up to 16 wavelengths on a single fibre Each set of 8 channels must first be connected like described in chapter 3 2 figure 3 Figure 5 16 chan...

Page 8: ...ul when connecting disconnecting fibre pigtails ends Never look directly into the pigtail of the laser fibre Never use microscopes magnifying glasses or eye loupes to look into a fibre end Use laser s...

Page 9: ...performance specification under the following environmental conditions Operating room temperature range 0 C to 50 C Operating relative humidity range 90 non condensing 2 The equipment will operate wit...

Page 10: ...rranty terms and conditions for the product s covered by this manual follow the General Sales Conditions by Network Electronics ASA These conditions are available on the company web site of Network El...

Page 11: ...The guidance on how the EFUP is to be calculated is not finalised at the time of writing See http www aeanet org GovernmentAffairs qfLeOpAaZXaMxqGjSFbEidSdPNtpT pdf for an unofficial translation of th...

Page 12: ...b site http www network electronics com Please contact Network Electronics Customer Support for assistance with recycling if this site does not show the information you require Where it is not possibl...