5.2 Front Panel - Status Monitoring 

The status of the module can be easily monitored visually by the LED’s at the front of the module. The 
LED’s are visible through the front panel as shown in figure 8 below. 
 

 

(Text not printed on the front panel). 

Figure 8 -  Front panel indicator overview for DA-HDSDI 

 

The DA-HDSDI has 4 LED’s each showing a status corresponding to the GPI pinning. The position of 
the different LED’s is shown in figure 8. 
 

Diode \ state  Red LED 

Yellow LED 

Green LED 

No light 

Status 

Module is faulty 
 

 

Module is OK 
Module power is OK 

Module has no 
power 

Rate 

Rate not detected 

SD rate found 

HD rate found 

 

LOS 

Loss of signal 
No input signal. 

LOS detection de-
activated (EQM=off) 

Input signal present 

 

LOCK 

Re-clocker is out of 
lock 

Re-clocker switched 
off 

Re-clocker is in lock 
on a supported signal 
format 

 

 

E-mail: [email protected] – Web: http://www.network-electronics.com/ 
 
Technical specifications are subject to be changed without notice. 

 

 

10

Summary of Contents for DA-HDSDI

Page 1: ...HD SDI Distribution Amplifier Network Electronics ASA Thor ya N 3204 Sandefjord Norway Phone 47 33 48 99 99 Fax 47 33 48 99 98 e mail support network electronics com www network electronics com E mail...

Page 2: ...evision history The latest version is always available in pdf format on our web site http www network electronics com Current revision of this document is the uppermost in the table below Revision Rep...

Page 3: ...l 4 2 Specifications 5 3 Format Configuration 6 3 1 Configuration Examples 7 4 Connector module 8 4 1 Mounting the connector module 8 5 Module status 9 5 1 GPI ALARM Module Status Outputs 9 5 2 Front...

Page 4: ...nd SD rates and automatically switch to correct output slew rate The re clocker supports the bit rates 143 177 270 360 540 and 1485Mbps For other rates the re clocker automatically switches to bypass...

Page 5: ...Number of outputs 6 Connector BNC Impedance 75 ohm Return loss 15dB acc to ITU R BT 1120 3 Jitter max 0 2UI Peak to peak signal level 0 8V 0 1V Signal polarity 3 non inverting 3 inverting Features Re...

Page 6: ...ting of equaliser when signal strength is to low Input mute 3 RCL Reclocker Bypass Reclocker ON Reclocker mode 4 EQ Cable equaliser Bypass Cable equaliser ON Equaliser mode 5 ASI SDI 177Mbps Reclocker...

Page 7: ...ypical configurations for DA HDSDI Figure 3 Default HD SDI SDI and DVB ASI Figure 4 Transparent Mode with equalisation and no reclocking Figure 5 AES3id compatible and Transparent Mode without equalis...

Page 8: ...NC and the electrical outputs are connected to the O1 to O6 BNC Please note that O2 O4 and O6 has an inverted signal so formats like DVB ASI can not use be used on these outputs Unused outputs should...

Page 9: ...oller is described in a separate user manual 5 1 GPI ALARM Module Status Outputs These outputs can be used for wiring up alarms for third party control systems The GPI outputs are open collector outpu...

Page 10: ...has 4 LED s each showing a status corresponding to the GPI pinning The position of the different LED s is shown in figure 8 Diode state Red LED Yellow LED Green LED No light Status Module is faulty Mo...

Page 11: ...y it thereby complies with the Electromagnetic Compatibility Directive 89 336 EEC General environmental requirements for Network flashlink equipment 1 The equipment will meet the guaranteed performanc...

Page 12: ...m Web http www network electronics com Technical specifications are subject to be changed without notice 12 Product Warranty The warranty terms and conditions for the product s covered by this manual...

Page 13: ...period This is defined as the period of normal use before any hazardous material is released to the environment The guidance on how the EFUP is to be calculated is not finalised at the time of writin...

Page 14: ...network electronics com Please contact Network Electronics Customer Support for assistance with recycling if this site does not show the information you require Where it is not possible to return the...

Reviews: