5.2 Front Panel - Status Monitoring
The status of the module can be easily monitored visually by the LED’s at the front of the module. The
LED’s are visible through the front panel as shown in figure 8 below.
(Text not printed on the front panel).
Figure 8 - Front panel indicator overview for DA-HDSDI
The DA-HDSDI has 4 LED’s each showing a status corresponding to the GPI pinning. The position of
the different LED’s is shown in figure 8.
Diode \ state Red LED
Yellow LED
Green LED
No light
Status
Module is faulty
Module is OK
Module power is OK
Module has no
power
Rate
Rate not detected
SD rate found
HD rate found
LOS
Loss of signal
No input signal.
LOS detection de-
activated (EQM=off)
Input signal present
LOCK
Re-clocker is out of
lock
Re-clocker switched
off
Re-clocker is in lock
on a supported signal
format
E-mail: [email protected] – Web: http://www.network-electronics.com/