
12
Monitoring the AT-FCX module
LED status on the
AT-FCX
The following illustration is of the second sheet of the quick reference cards that
come with your disk shelf.
AT-FCX console
error messages
The following error messages appear on the storage appliance console if an SES
element on the AT-FCX module fails. See “
Hot-Swapping the AT-FCX module
on page 34 for more information. The output displayed on the console is similar
to the following example.
Example:
Mon Aug 25 21:34:05 GMT [ses.status.temperatureWarning:warning]:
DS14-Mk2-AT shelf 3 on channel 5a temperature warning for
Temperature sensor 1: non-critical status; undertemperature
warning. Current temperature: 1 C (33 F). This module is on the
front side of the shelf, at the right, on the OPS panel.