7
5-6. Battery Power and Low Voltage Alarm
ZB11D will send a low-power report to the ZigBee network when the operating voltage is lower than 3.2V by
default.
The related data:
Power configuration cluster (ID: 0x0001)
Battery voltage attribute (ID: 0x0020)
The reporting voltage can be adjusted. There are 4 voltages for choosing: 3.5V / 3.4V / 3.3V / 3.2V.
It is recommended that the minimal reporting internal is longer than 5-minute.
5-7. Restore to Factory Setting
To restore it to factory setting, please follow the steps:
Step1. Press and hold the
Auxiliary Key
for 10 seconds.
Step2. Release the button after the indicator shows fast
green
flashes to complete the restore.
5-8. Testing Mode Set-up
5-9. Sleeping Mode
ZB11D is designed to go into sleeping mode for power-saving in some situations:
A. While the device is in the network → the sleeping period is 5 minutes; it will wake up every 5
minutes to keep online.
B. When it doesn’t find a network to join → ZB11D will go to sleeping mode. It will wake up every 15
minutes to search a network to join.
C. Once ZB11D was joined to a network and by any chance the network is no longer existed or the
device is out of the network → ZB11D will wake up every 15 minutes to find the network it joined
before.
It never keeps in sleeping mode and continues to find out a network every 15 minutes. This condition would
consume up to 30 times power spending compared to normal-operating status. To prevent this unwanted power
consumption, we recommend that users remove the batteries to power off the device.
5-10. Binding
To bind ZB11D with other devices which support attribute 0x0000 (occupancy) of Occupancy Sensing Cluster