8
Under the circumstances that Z311C has enrolled to the security system, it will send the contact status to the
command center (and the bound devices with ID: 0x0500) after triggering. The Warning Device will send out
alarm sound or lighting alert for warning.
Under the circumstances that Z311C hasn’t enrolled to the security system, it will try enroll in a security
system after triggering. After the enrollment, Z311C will send the contact status to the command center.
ZoneStatusChange commands: 0x00.
The command list:
Bits:8
8
8
var
Frame
control
Transaction
Sequence
number
Command
identifer
Frame payload
16-Bit Enumeration
8-Bit Enumeration
0x09
0x00
ZoneStatus
ExtendedStatus
(
Clusterid
:
0x 0500
)
Values of the ZoneStauts payload
ZoneStatus
Attribute Bit Number
Meaning
Values
0
Alarm1
1 – opened or alarmed
0 – closed or not alarmed
1
Alarm2
1 – opened or alarmed
0 – closed or not alarmed
2
Tamper
1 – Tampered
0 – Not tampered
3
Battery
1 – Low battery
0 – Battery OK
4
Supervision reports
1 – Reports
0 – Does not report
5
Restore reports
1 – Reports restore
0 – Does not report restore
6
Trouble
1 – Trouble/Failure
0 – OK
7
AC (mains)
1 – AC/Mains fault
0 – AC/Mains OK
8-15
Reserved
Values of the ExtendedStatus payload
ExtendedStatus
Attribute Bit Number
Meaning
Values
0-6
ZoneID
7
ZoneStatusChange Or Heartbeat
1 – HeartBeat
0 – ZoneStatusChange
Summary of Contents for Z311C