background image

9

7.4 Detection coverage

Horizontal projected area

Space projected area

IR coverage range:

The coverage area A- Distance: 11 meters; sensing angle: 30°.
The coverage area B- Distance: 8 meters; sensing angle: 60°.
The coverage area C- Distance: 5 meters; sensing angle: 120°.

8. Important Maintenance Instruction

Your device is a product of superior design and craftsmanship and should be used with care. The
following suggestions will help you use the warranty service effectively.

Keep the equipment dry. Rain, moisture, and various liquids or moisture may contain minerals
that can corrode electronic circuits. In case the device is wet, please dry it completely.

Do not use or store in dusty or dirty areas. This can damage its detachable parts and electronic
components.

Do not store in excessive heat. High temperatures can shorten the life of electronic devices,
destroy batteries, and deform or melt some plastic parts.

Do not store in excessive cold place. Otherwise, when the temperature rises to normal temperature,moisture will form inside, which will destroy the
board.

Do not throw, knock or shake the device. Rough handling of equipment can destroy internal
circuit boards and delicate structures.

Do not wash with strong chemicals, detergents or strong detergents.

Do not apply with paint. Smudges can block debris in detachable parts and affect normal
operation.

Do not throw the battery into a fire to prevent the battery from exploding. Damaged batteries
may also explode.

All of the above suggestions apply equally to your device, battery and accessories.
If any device is not working properly.
Please take it to the nearest authorized service facility for repair.

Summary of Contents for RB11E

Page 1: ...Model RB11E Wireless Occupancy Temperature Light Sensor Wireless Occupancy Temperature Light Sensor User Manual ...

Page 2: ...nstruction 3 5 Data Report 4 6 IR Delay Configuration 6 7 Installation 7 7 1 Tips for installing the double sided stickers 7 7 2 Tips for installing the steel nails 7 7 3 Installation requirements 8 7 4 Detection coverage 9 8 Important Maintenance Instruction 9 9 FCC Statement 10 ...

Page 3: ... Compared with other communication methods LoRa spread spectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation equipment wireless security systems industrial monitoring Main features include small size low power consumption transmission distance anti inter...

Page 4: ...flashes for 20 times and enters off mode Power off Remove Batteries Note 1 Remove and insert the battery the device will be at off state by default Press the function key till the green and red indicator flash once and then release to turn on 2 On off interval is suggested to be about 10 seconds to avoid the interference of capacitor inductance and other energy storage components Network Joining N...

Page 5: ...e voltage value are checked per Min Interval Default reportchange Battery 0x01 0 1V Temperature 0x0064 1 C Illumination 0x0064 100Lux Infrared trigger After the RB11E device detects the infrared the red LED blinks once and immediately reports the status values of all the current sensors Infrared status bits Someone 1 No one 0 Note The data transmission cycle of the device is subject to the program...

Page 6: ...e Change i e BatteryVoltageChange 0 1V MaxTime Sleeping MinTime sleeping sleeping sleeping 0H 15th M 30th M 45th M 1H 2H Description Device CmdID DeviceTyp e NetvoxPayLoadData ConfigReportReq RB11E 0x01 0x03 MinTime 2b ytes Unit s MaxTime 2byt es Unit s BatteryChange 1 byte Unit 0 1v TemperatureC hange 2byte Unit 0 01 illuminance 2byte Unit 1Lux ConfigReportRsp 0x81 Status 0x00_ success Reserved 8...

Page 7: ...eriod For example after triggered the PIR will turn off the infrared probe for 21 30 70 seconds to save the power living objects within this period will not be detected PIR will re open detection function after 21 seconds if it detects living objects in this period the IR delay time will be extended for another 30 seconds till no infrared signal is detected and IRDetectionTime period is due and RB...

Page 8: ...sticker and put the sticker to a clean surface of the wall the direction of arrow shows up and press the sticker firmly for around 20 seconds Note 1 The white release paper side with gray letters 3M9080A is for the wall The brown release paper side with green letters 3M300LSE is for the plastic base of the product 2 Make sure there is no dust on the surface of the wall wipe the dust and dirt off t...

Page 9: ...equirements 1 Indoor use only please check the installation places The sensitivity of the PIR sensor has a lot to do withe the motion direction of the human body The PIR sensor is more sensitive to vertical motions while it is less sensitive to horizontal motions Thus it is important to choose the proper location for installation and higher sensitivity ...

Page 10: ...rts and electronic components Do not store in excessive heat High temperatures can shorten the life of electronic devices destroy batteries and deform or melt some plastic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can ...

Page 11: ...B Z100B or A RF transmitter inside FCC ID NRH ZB Z100B You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any inte...

Reviews: