6. Installation

1. Align the mounting bayonet at the bottom of

the sensor (the red circle in the figure below)

with the assembly post of the base (the red

circle in the figure below) and press it into

the base, and then gently rotate the sensor

counterclockwise into place.

2. When the smoke sensor detects that the

smoke concentration exceeds the set value

or the temperature exceeds 60°C, the device

will send an "alarm" message.

When the smoke concentration is lower

than the set value and the regular reporting

time is up, the device will return to the

normal state and send the "normal"

message.

3. RA02A is suitable for the following scenarios:

Residential

Hotel

Apartment

Ballroom

Coffee shop

Smart cities or smart buildings

4. RA02A is not suitable for the following scenarios

Places with a large amount of dust, powder, and water mist

Places where steam and oil mist may be generated

Kitchens and places where smoke stays under normal circumstances

Places with excessive temperature and humidity

Summary of Contents for RA02A

Page 1: ...ontains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without...

Page 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Feature 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Important Maintenance Instruction 10...

Page 3: ...ds LoRa spread spectrum modulation technique greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communications For exampl...

Page 4: ...d alerts can be set via SMS text and email optional Applicable to the third party platforms Actility ThingPark TTN MyDevices Cayenne Low power consumption and long battery life Note Battery life is de...

Page 5: ...search the network The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search the previous network The green indicator...

Page 6: ...hen the temperature is higher than 60 degrees Celsius the buzzer will alarm the red indicator will flash and a report will be sent immediately The fire alarm bit is 1 If the alarm continues the report...

Page 7: ...00000000 Configuration failure 2 Read Configuration Downlink 020A000000000000000000 Response 820A003C003C0100000000 Current configuration Description Device CmdID Device Type NetvoxPayLoadData Config...

Page 8: ...M 1H 25th M 1H 40th M 1H 55th M 2H 10th M Wakes up and collects data 2 8V Does not report Wakes up and collects data REPORTS 2 8V Wakes up and collects data REPORT 2 8V Wakes up and collects data REPO...

Page 9: ...rts according to MinTime interval If the data variation is not greater than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval va...

Page 10: ...e will send an alarm message When the smoke concentration is lower than the set value and the regular reporting time is up the device will return to the normal state and send the normal message 3 RA02...

Page 11: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Reviews: