R72615A is a ClassA type device based on the LoRaWAN open protocol. 

R72615A is connected to a variety of sensors. As detectors for CO2, temperature and humidity, the values collected by the sensor 

are reported to the corresponding gateway.   

 

LoRa Wireless Technology: 

LoRa is a wireless communication technology famous for its long-distance transmission and low power consumption. Compared 

with other communication methods, LoRa spread spectrum modulation technique greatly extend the communication distance. It 

can be widely used in any use case that requires long-distance and low-data wireless communications. For example, automatic 

meter reading, building automation equipment, wireless security systems, industrial monitoring. It has features like small size, 

low power consumption, long transmission distance, strong anti-interference ability and so on. 

 

LoRaWAN: 

LoRaWAN uses LoRa technology to define end-to-end standard specifications to ensure interoperability between devices and 

gateways from different manufacturers.   

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for R72615A

Page 1: ...echnology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other par...

Page 2: ...3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 8 7 Information about Battery Passivation 10 7 1 To determine whether a battery requires activation 10 7 2 How to activate the...

Page 3: ...mmunication methods LoRa spread spectrum modulation technique greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communic...

Page 4: ...le with LoRaWAN 7 2V battery power supply Simple operation and setting CO2 and temperature and humidity detection Adopt SX1276 wireless communication module Temperature and Humidity Sensor CO2 Sensor...

Page 5: ...o factory setting Turn off The green indicator flashes for 20 times success The green indicator remains off fail Press once The device is in the network The green indicator flashes once R72615A will s...

Page 6: ...value if you were to manually trigger the device by pressing the button please be patient Note 1 The device report interval will be programmed base on the default firmware which may vary 2 The interva...

Page 7: ...0PPM 0FA0 Hex 4000 Dec 4000 0 1PPM 400PPM 7th 8th byte FFFF NH3 data is not available 9th 10th byte FFFF Noise data is not available 11th byte 00 Reserved Packet 2 01090C4809C41B58FFFF00 1st byte 01 V...

Page 8: ...0000000000000000 the configuration is failed 2 Read the R72615A device configuration parameters Downlink 0209000000000000000000 Devices return 8209001E0E100000000000 device current configuration param...

Page 9: ...s of the battery pack before installation and insert 8 ER14505 3 6V batteries into the battery compartment 4 sections on the front and 4 sections on the back side as shown in Figure 1 2 Figure 1 Batte...

Page 10: ...ta regularly according to MaxTime default 720 min and take about 180 seconds for the CO2 sensor to sample and process the collected CO2 value The packets have temperature humidity CO2 and battery volt...

Page 11: ...passivation may also lead to voltage delay when the batteries are put into operation and our devices may not work correctly in this situation As a result please make sure to source batteries from rel...

Page 12: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Reviews: