7
Description
Device
CmdI
D
Device
Type
NetvoxPayLoadData
Config
ReportReq
R720FLT
0x01
0xD4
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
BatteryChange
(1byte Unit:0.1v)
Reserved
(4Bytes,Fixed
0x00)
Config
ReportRsp
0x81
Status
(0x00_success)
Reserved
(8Bytes,Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved
(9Bytes,Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
BatteryChange
(1byte Unit:0.1v)
Reserved
(4Bytes,Fixed
0x00)
(1)
Configure R720
FLT device parameter MinTime = 1min
、
MaxTime = 1min
、
BatteryChange = 0.1v
Downlink:
01D4003C003C0100000000 // 3C(Hex)=60(Dec)
Device return
:
81D4000000000000000000 (configuration success)
81D4010000000000000000 (configuration failure)
(2)
Read R720
FLT device parameter
Downlink: 02D4000000000000000000
Device return
:
82D4003C003C0100000000 (device current parameter)
Description
Device
Cmd
ID
Device
Type
NetvoxPayLoadData
SetFaultCheckTimeReq
(Remain last config when
reset to factory)
R720FLT
0x03
0xD4
FalutCheckTime
(2Byte,Unit:1s )
Reserved
(7Bytes,Fixed 0x00)
SetFault
CheckTimeRsp
0x83
Status
(0x00_success)
Reserved
(8Bytes,Fixed 0x00)
GetFault
CheckTimeReq
0x04
Reserved
(9Bytes,Fixed 0x00)
GetFault
CheckTimeRsp
0x84
FalutCheckTime
(2Byte,Unit:1s )
Reserved
(7Bytes,Fixed 0x00)
Clear
ReplenishwatercountReq
0x05
Reserved
(9Bytes,Fixed 0x00)
Clear
ReplenishwatercountRsp
0x85
Status
(0x00_success)
Reserved
(8Bytes,Fixed 0x00)
SetDailyReplenishwater
AlarmcountReq
(Remain last config when
reset to factory)
0x06
DailyReplenishwater
Alarmcount (2Byte )
Reserved
(7Bytes,Fixed 0x00)